Mounting the Camera
MX-U Series Processor and Camera Guide
Datalogic Automation, Inc.
3-4
mounting bolt holes (see diagram).
2. Turn the mounting bolts clockwise to tighten them and secure the block to the camera.
3. Use appropriately sized fasteners in the pre-threaded holes in the bottom of the mounting block to secure it to a
rigid surface for proper stability and heat transfer. (See “U1xx Camera Dimensions” on page 3-3.)
U1xx Mounting Block
(381-1355)
Camera front faces
this direction
Bottom View
UNITS: inch [mm.]
Block Mounting bolts
M3; 4.5mm deep (2 ea.)
¼"-20; 8mm deep
(2 ea.)
M5 x 0.8; 8mm deep
(2 ea.)
0.39 [10.0]
0.53 [13.35]
1.65 [42]
0.39 [10.0]
0.69 [17.4]
Содержание MX-U Series