CBX ELECTRICAL CONNECTIONS
78
MATRIX 320
OUTPUTS
Three general purpose outputs are available and their meaning can be defined by the
user. They are typically used either to signal the data collection result or to control an
external lighting system.
CBX100/500
Description
+V
Power Source - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
O3A
Output 3 non opto-isolated (only available on CBX500)
-V
Power Reference - Outputs
The electrical features of the outputs are the following:
Outputs 1 and 2
Output 3
V
CE
= 30 Vdc max.
Reverse-Polarity and Short-Circuit Pro-
tected
I
CE
= 40 mA continuous max.; 130 mA
pulsed max.
V
OUT
(I
LOAD
= 0 mA) max = 30 Vdc
V
CE saturation
= 1 Vdc max. @ 10 mA
V
OUT
(I
LOAD
= 100 mA) max = 3 Vdc
P
D
= 90 mW Max. @ 50 °C ambient temp.
I
LOAD
max = 100 mA
By default, Output 1 is associated with the No Read event, which activates when the
code(s) signaled by the external trigger are not decoded, and Output 2 is associated
with the Good Read event, which activates when all the selected codes are correctly
decoded.
The output signals are fully programmable being determined by the configured Activa-
tion/Deactivation events, Deactivation Timeout or a combination of the two. Refer to
the DL.CODE parameters Help On Line for further details.
CAUTION
When
Outputs 1
and 2 are connected through the CBX connection box,
they become opto-isolated and polarity sensitive and acquire the elec-
trical characteristics listed below. To function correctly, they require
setting the Output Line Type configuration parameters to NPN for the
respective output. The hardware connection to the CBX can be either
NPN or PNP.
Содержание Matrix 320
Страница 1: ...Matrix 320 PRODUCT REFERENCE GUIDE Image Based Industrial Reader...
Страница 84: ...CBX ELECTRICAL CONNECTIONS 70 MATRIX 320 Figure 50 ID NET Network Connections with Common Power Star Network...
Страница 88: ...CBX ELECTRICAL CONNECTIONS 74 MATRIX 320 Figure 54 NPN External Trigger Using Matrix 320 Power...
Страница 133: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 119...
Страница 141: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 127...
Страница 143: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 129 Open the cloned application job...
Страница 166: ...DPM Data Matrix and QR codes on metal surfaces Non polarized Polarized ILLUMINATORS 152 MATRIX 320...