![Datalogic Matrix 220 Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/datalogic/matrix-220/matrix-220_product-reference-manual_3704091092.webp)
ELECTRICAL CONNECTIONS
74
MATRIX 220
RS232 Interface
The RS232 interface is generally used for Point-to-Point connections. When it is con-
nected to the host computer it allows transmission of code data.
The following pins are used for RS232 interface connection:
CBX100/500
Description
TX
Transmit Data
RX
Receive Data
SGND
Signal Ground
It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft).
User Interface
Reader
RX
TX
SGND
TXD
RXD
SGND
Figure 48 - RS232 Main Interface Connections
RS422 Full Duplex Interface
The RS422 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft)
than those acceptable for RS232 communications or in electrically noisy environments.
The CBX pinout follows:
CBX100/500
Description
TX+
RS422 Transmit Data +
RX+
RS422 Receive Data +
TX-
RS422 Transmit Data -
RX-
RS422 Receive Data -
SGND
Signal Ground
Содержание Matrix 220
Страница 1: ...Matrix 220 PRODUCT REFERENCE GUIDE Image Based Reader...
Страница 18: ...GENERAL VIEW xviii MATRIX 220...
Страница 29: ...STEP 5 INSTALLING DL CODE CONFIGURATION PROGRAM PRODUCT REFERENCE GUIDE 11 Figure 12 DL CODE Opening Window...
Страница 98: ...ELECTRICAL CONNECTIONS 80 MATRIX 220 Figure 54 ID NET Network Connections with Common Power Star Network...
Страница 102: ...ELECTRICAL CONNECTIONS 84 MATRIX 220 Figure 57 NPN External Trigger Using Matrix 220 Power...
Страница 163: ...PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 145...
Страница 171: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 153...
Страница 173: ...INTERNAL NETWORK CONFIGURATIONS PRODUCT REFERENCE GUIDE 155 Open the cloned application job...
Страница 211: ......