STEP 4 – X-PRESS™ CONFIGURATION
Once Matrix 210™ is positioned with respect to the code (step 3), you can configure it for optimal code reading relative to your
application. This configuration can be performed either through the X-PRESS™ Interface or the VisiSet™ configuration program.
SETUP
1.
Enter the Setup function by pressing and holding the X-PRESS™ push
button until the Setup LED is on.
2. Release the button to enter the Setup function. The Setup LED will
blink until the procedure is completed.
The Setup procedure ends when the Image Acquisition parameters are
successfully saved in the reader memory, the Setup LED will remain on
continuously and Matrix 210™ emits 3 high pitched beeps.
If the calibration cannot be reached after a timeout of about 5 (five)
seconds Matrix 210™ will exit without saving the parameters to memory,
the Setup LED will not remain on continuously but it will just stop blinking.
In this case Matrix 210™ emits a long low pitched beep.
3.
Exit the Setup function by pressing the X-PRESS™ push button once.
green
green
yellow
yellow
red
Figure 9 – X-PRESS™ Interface: