![Datalogic Matrix 120 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/datalogic/matrix-120/matrix-120_product-reference-manual_4109818070.webp)
CBX ELECTRICAL CONNECTIONS
56 MATRIX 120™
POWER SUPPLY
Power can be supplied to the reader through the CBX100/500 spring clamp terminal
pins as shown in Figure 36:
Figure 36 - Power Supply Connections
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for
details.
MAIN SERIAL INTERFACE
The signals relative to the following serial interface types are available on the CBX spring
clamp terminal blocks.
The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via DL.CODE software. For more details refer to the Help On Line
page of the Reading Phase step (Channels) in DL.CODE.
Details regarding the connections and use of the interfaces are given in the next para-
graphs.
This interface can also be used for configuration through DL.CODE, see Step 4C - Serial
Device Discovery.
RS232 Interface
The RS232 interface is generally used for Point-to-Point connections. When it is con-
nected to the host computer it allows transmission of code data.
The following pins are used for RS232 interface connection:
CBX100/500
Description
TX
Transmit Data
RX
Receive Data
SGND
Signal Ground
CAUTION
Do not connect to the Main Interface spring clamp terminals if using Host
Interface Modules (Fieldbus) with the CBX500.
Содержание Matrix 120
Страница 1: ...Matrix 120 PRODUCT REFERENCE GUIDE Image Based Reader...
Страница 14: ...GENERAL VIEW XIV MATRIX 120...
Страница 63: ...mm in MECHANICAL DIMENSIONS PRODUCT REFERENCE GUIDE 49 Figure 29 Mounting Bracket Overall Dimensions...
Страница 75: ...INPUTS PRODUCT REFERENCE GUIDE 61 Figure 41 NPN External Trigger Using Matrix 120 Power...
Страница 95: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 81 2D Codes Figure 64 Global FOV 2D Code Diagram for MP Models...
Страница 97: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 83 Matrix 120 310 xxA Models Digimarc Barcode...
Страница 149: ...IMAGE CROPPING PRODUCT REFERENCE GUIDE 135 The cropped area can be moved by dragging the center...
Страница 153: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 139...
Страница 177: ...OUTPUTS PRODUCT REFERENCE GUIDE 163 Figure 4 NPN Output Connection Figure 5 Push Pull Output Connection...
Страница 185: ......
Страница 186: ......
Страница 187: ......