TROUBLESHOOTING
152 MATRIX 120™
Troubleshooting Guide
Problem
Suggestion
DL.CODE Installation:
Autorun or Start.hta
doesn’t run
Check Windows settings to see if Autorun is disabled.
Associate the file type .hta with the Microsoft HTML Application
host
mshta.exe
in Windows\System32.
Driver Installation
Error:
The ECM driver fails to
install correctly.
Windows 7 requires that update KB3033929 be installed in
order for the Matrix 120™ ECM driver to work properly.
Power ON:
the “POWER” LED is
not lit.
Is power connected?
If using a power adapter (like PG6000), is it connected to wall
outlet?
If using rail power, does rail have power?
If using CBX, does it have power (check switch and LED)?
Check if you are referring to the device / accessory cable or to
the CBX spring clamp connectors.
Measure Voltage either at pin
1
and pin
2
(for 17-pin connector)
or at spring clamp
Vdc
and
GND
(for CBX).
One Shot or Phase
Mode using the Input
1 (External Trigger) or
Input 2:
the ”TRIGGER” LED is
not blinking while the
External Trigger is
switching.
Check if you are referring to the 17-pin connector or to the CBX
spring clamp connectors.
Is the sensor connected to Input 1 or Input 2?
Is power supplied to the photo sensor?
For NPN configuration, is power supplied to one of the two I1 or
I2 signals (A or B)?
For PNP configuration, is one of the two I1 or I2 signals
grounded (A or B)?
Are the photo sensor LEDS (if any) working correctly?
Is the sensor/reflector system aligned (if present)?
On the Reading Phase step check the Input 1 or Input 2
Deboun-
cing Time
parameter setting.
On the Reading Phase step check the settings for
Acquisition
Trigger, Reading Phase-ON,
and
Reading Phase-OFF
parame-
ters.
One Shot or Phase
Mode using serial
trigger source:
the ”TRIGGER” LED is
not blinking.
On the Reading Phase step check the settings for
Acquisition
Trigger, Reading Phase-ON,
and
Reading Phase-OFF
parame-
ters.
Are the COM port parameters (
Baud Rate, Parity, Data Bits, Stop
Bits
) correctly assigned?
On the Reading Phase step check the settings of
Acquisition
Trigger String, Reading Phase-ON String,
and
Reading Phase-
OFF String
parameters.
Is the serial trigger source correctly connected?
Содержание Matrix 120
Страница 1: ...Matrix 120 PRODUCT REFERENCE GUIDE Image Based Reader...
Страница 14: ...GENERAL VIEW XIV MATRIX 120...
Страница 63: ...mm in MECHANICAL DIMENSIONS PRODUCT REFERENCE GUIDE 49 Figure 29 Mounting Bracket Overall Dimensions...
Страница 75: ...INPUTS PRODUCT REFERENCE GUIDE 61 Figure 41 NPN External Trigger Using Matrix 120 Power...
Страница 95: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 81 2D Codes Figure 64 Global FOV 2D Code Diagram for MP Models...
Страница 97: ...GLOBAL FOV DIAGRAMS PRODUCT REFERENCE GUIDE 83 Matrix 120 310 xxA Models Digimarc Barcode...
Страница 149: ...IMAGE CROPPING PRODUCT REFERENCE GUIDE 135 The cropped area can be moved by dragging the center...
Страница 153: ...Reader 2 Reader 3 PASS THROUGH CONFIGURATIONS PRODUCT REFERENCE GUIDE 139...
Страница 177: ...OUTPUTS PRODUCT REFERENCE GUIDE 163 Figure 4 NPN Output Connection Figure 5 Push Pull Output Connection...
Страница 185: ......
Страница 186: ......
Страница 187: ......