MATRIX 120™ REFERENCE MANUAL
120
10
10 TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
Supply Voltage
5 to 30 Vdc
(10 to 30 Vdc with CBX)
Consumption
0.4 to 0.1 A
Communication Interfaces
Main
- RS232
- RS422 full-duplex
2400 to 115200 bit/s
2400 to 115200 bit/s
USB
USB 2.0 Hi-Speed
Ethernet (Built-in)
supported application protocols
10/100 Mbit/s
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
Fieldbus
CBX500 with HMS Host Interface Modules
Inputs
Input 1(External Trigger) and Input 2
short circuit protected
(opto-isolated and polarity insensitive when connected through CBX)
Max. Voltage
30 Vdc
Max. Input Current
3.5 mA (24 mA max when connected through CBX)
Outputs
3
Output 1 and 2
NPN or PNP short circuit protected
(opto-isolated and polarity sensitive when connected through CBX)
V
OUT high
(I
LOAD
= -100 mA) Max.
28.3 Vdc (when using 30 Vdc power supply)
V
OUT low
(I
LOAD
= 100 mA) Max.
1.7 Vdc
I
LOAD
Max.
145 mA
OPTICAL FEATURES
WVGA
MP
Image Format
752x480
1280x960
Frame Rate
57 frames/sec.
36 frames/sec.
Focus Range
4
Factory calibrated positions (mm)
45
– 70 - 125
45
– 80 - 125
Image Sensor
CMOS sensor with Global Shutter
Pitch
35°
Tilt
0° - 360° (within vertical FOV)
LED Safety
to EN 62471
Laser Safety (Aiming source)
IEC60825-1 2007
Lighting System
Internal Illuminator
Aiming System
Laser Indicator
ENVIRONMENTAL FEATURES
Operating Temperature
5
0 to 45
C (32 to 113 °F)
Storage Temperature
-20 to 70
C (-4 to 158 °F)
Max. Humidity
90% non condensing
Vibration Resistance
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
EN 60068-2-6
2 g @ 70 to 500 Hz; 2 hours on each axis
Shock Resistance
30g; 11 ms;
EN 60068-2-27
3 shocks on each axis
Bump Resistance
30g; 6 ms;
EN 60068-2-29
5000 shocks on each axis
Protection Class
EN 60529
IP65
3
when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
CE
= 30 Vdc max.; I
CE
= 40 mA continuous max.; 130 mA pulsed max.;
V
CE saturation
= 1 Vdc max. @ 10 mA; P
D
= 90 mW Max. @ 50 °C ambient temp.
4
three factory calibrated positions; continuous focus range for fine tuning
5
high ambient temperature applications should use metal mounting bracket for heat dissipation
Содержание Matrix 120
Страница 1: ...REFERENCE MANUAL Matrix 120...
Страница 51: ...INSTALLATION 39 3 Figure 24 Overall Dimensions of Matrix 120 Ethernet Models with ESD Cover Optical Axis mm in...
Страница 52: ...MATRIX 120 REFERENCE MANUAL 40 3 Figure 25 Overall Dimensions of Matrix 120 USB Models Optical Axis mm in...
Страница 53: ...INSTALLATION 41 3 Figure 26 Overall Dimensions of Matrix 120 USB Models with ESD Cover Optical Axis mm in...
Страница 54: ...MATRIX 120 REFERENCE MANUAL 42 3 Figure 27 Mounting Bracket Overall Dimensions mm in...
Страница 65: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 39 NPN External Trigger Using Matrix 120 Power NPN Photoelectric Sensor...
Страница 144: ......