MATRIX 120™ REFERENCE MANUAL
90
6
Likewise,
T
exp
(max)
is the maximum
Exposure Time
value that can be used without blurring
for the given application line speed and code resolution. Therefore:
X / LS = T
exp
(max)
T
exp (max)
and
LS
(max)
are represented in the graph below as the curved line for
X
(code
resolution). Values above the curve result in blurring. In practice, the application values are
somewhere below the theoretical line, (in the green area), due to environmental and other
conditions.
Line Speed
T
exp
SW Limit
T
exp (min)
SW/HW Limit
X
2X
Con
ve
yor
Sp
ee
d
Lim
it
Readable
Blurring
For example, the maximum target speed in the application is also affected by these
conditions:
Code/Background Contrast
: maximum speed decreases when decreasing image
contrast (poor quality codes, reflective transparent coverings, different supports and
printing techniques).
Code Resolution
: maximum speed increases when decreasing code resolution, (i.e.
2X)
.
There is a decrement of overlapping effects between two adjacent elements.
Tilt Angle
: maximum speed decreases when increasing Tilt angle (from 0 to 45 degrees).
The
Internal Lighting
parameter allows setting the operating mode of the internal lighting
system. The possible values are:
Disabled
: the built-in LED array is turned off all the time. This option can be useful if using
an external lighting system;
-Very High Power Strobed
: the built-in LED array is on only during the image exposure
time.
NOTE:
To avoid LED array overheating, for Power Strobed settings, the
program automatically limits the range of allowed values for the
Exposure
Time
parameter. Therefore, after changes to
Internal Lighting
, recheck
Exposure Time
.
Содержание Matrix 120
Страница 1: ...REFERENCE MANUAL Matrix 120...
Страница 51: ...INSTALLATION 39 3 Figure 24 Overall Dimensions of Matrix 120 Ethernet Models with ESD Cover Optical Axis mm in...
Страница 52: ...MATRIX 120 REFERENCE MANUAL 40 3 Figure 25 Overall Dimensions of Matrix 120 USB Models Optical Axis mm in...
Страница 53: ...INSTALLATION 41 3 Figure 26 Overall Dimensions of Matrix 120 USB Models with ESD Cover Optical Axis mm in...
Страница 54: ...MATRIX 120 REFERENCE MANUAL 42 3 Figure 27 Mounting Bracket Overall Dimensions mm in...
Страница 65: ...CBX ELECTRICAL CONNECTIONS 53 4 Figure 39 NPN External Trigger Using Matrix 120 Power NPN Photoelectric Sensor...
Страница 144: ......