background image

Single Cable RS-232

Enter/Exit Programming Mode

Product Reference Guide

        

                

   61

Single Cable RS-232 Use STX

Enables/disables the ability of the scanner to use STX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disable STX

Enable STX

DEFAULT

Set Single Cable RS-232 STX Character

This feature selects the STX character.
To specify the STX Character:

1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, SET SINGLE CABLE RS-232 STX CHARACTER below. 

You’ll need to cover any unused bar codes on this and the facing page to 

ensure the scanner reads only the bar code you intend to scan.

3. Scan the appropriate characters/digits from the keypad in Appendix  that 

represent the decimal designation for the desired character. A table con-

taining the ASCII Character Set and their corresponding hex values is 

available in the inside back cover of this manual. ASCII parameters must be 

input by scanning decimal digits for each character. Pad all numbers with 

leading zeroes to yield a three-digit entry (001-127). Thus, to set a single 

character value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must 

be scanned. The selectable range for this option is any decimal value from 

001 to 127.

4. The scanner will automatically exit Programming Mode when the appro-

priate amount of digits have been scanned.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET SINGLE CABLE RS-232 STX CHARACTER

Содержание MAGELLAN 3200VSI

Страница 1: ...Magellan 3200VSi Product Reference Guide...

Страница 2: ...by con tacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our web site and...

Страница 3: ...ear Labels 13 Double Read Timeout for 2D Labels 15 Scanner Button Options 16 Camera Button Mode 17 Auto Cell Phone Mode 18 Auto Cell Phone Mode Enable 18 LED Level 19 Auxiliary Port Mode 20 Auxiliary...

Страница 4: ...nsmission Failure Indication 57 Single Cable RS 232 58 Single Cable RS 232 Options 58 Single Cable RS 232 RTS CTS Selection 59 Single Cable RS 232 Use BCC 60 Single Cable RS 232 Use ACK NAK 60 Single...

Страница 5: ...97 GS1 DataBar Omnidirectional Stacked Omnidirectional 99 Disable Enable GS1 DataBar Omnidirectional 99 UCC EAN 128 Emulation 99 GS1 DataBar Expanded Expanded Stacked 100 Disable Enable GS1 DataBar Ex...

Страница 6: ...119 MSI 120 Disable Enable MSI 120 MSI Check Character Transmit 120 MSI Check Character Calculation 121 MSI Number of Check Characters 121 MSI Length Control 122 MSI Length 1 Length 2 Programming Inst...

Страница 7: ...mance Parameters 149 Scanner Dimensions 149 Physical Properties 150 Electrical Parameters 150 Environmental Parameters 150 Other Parameters 150 LED and Beeper Indicators 151 Appendix BCable Pinouts 15...

Страница 8: ...8 Supplemental 186 UPC E 187 UPC E with 2 Digit Supplemental 187 UPC E with 5 Digit Supplemental 187 UPC E with Code 128 Supplemental 187 EAN 8 188 EAN 8 with 2 Digit Supplemental 188 EAN 8 with 5 Dig...

Страница 9: ...ty information see the Quick Reference Guide QRG Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual On leaving the f...

Страница 10: ...l not support POT Power Off the Terminal to supply scan ner power use the approved power supply AC Adapter as shown in Figure 1b Plug the AC Adapter barrel connector into the socket on the RS 232 cabl...

Страница 11: ...9 USB SD Cover 3 Camera Push Button 10 USB Service Port On Screen Pro gramming Tool 4 Scan Window 11 microSD Card Slot Upgrade imag ing statistics data 5 Cable Connector Cover 12 Host blue Port POS t...

Страница 12: ...LED simultaneous to the beeps The table below describes what these codes mean and what action should be taken for each NUMBER OF LED FLASHES BEEPS ERROR CORRECTIVE ACTION 1 Configuration Contact Helpd...

Страница 13: ...scanner being seated in an L Bracket Figure 4 demonstrates the use of stackable Risers NOTE Stackable Risers also require use of the L Bracket in order to securely seat the scanner in the topmost rise...

Страница 14: ...using two screws through the bottom face of the bracket see Figure 3 If risers are used secure a riser to the countertop by attaching two screws through its screw holes Recommendation Use two Pan Hea...

Страница 15: ...behave differently Host Disable Constant green flash at 1 Hz 100mS on 900mS off The scanner is disabled due to receiving a disable command from the POS terminal Diagnostics Varies see Error Codes on p...

Страница 16: ...8 Magellan 3200VSI NOTES...

Страница 17: ...ng Bar Codes The scanner is typically factory configured with a set of default features stan dard to the interface type you ordered After scanning the interface bar code from the Interface Related Fea...

Страница 18: ...configuration Standard Product Default Settings The programming section lists the factory default settings for each of the menu commands for the standard RS 232 interface in BOLD text on the followin...

Страница 19: ...o present them only one at a time to the scanner a bar code mask is provided on the opposite side of this page Going Green Thank you for using the bar code mask on the opposite side of this page This...

Страница 20: ...m the manual as indicated to create a sleeve through which bar codes starting in the following section can be indi vidually viewed and scanned It is important that only one bar code at a time be prese...

Страница 21: ...Read Timeout for Linear Labels This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again e g two identical items in success...

Страница 22: ...0 7 Second 0 8 Second 0 9 Second 1 Second Enter Exit Programming Mode 14 Magellan 3200VSI Double Read Timeout for Linear Labels continued...

Страница 23: ...This Double Read Timeout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417 Micro PDF 417 Data Matrix QR Code Maxicode Aztec or Composite label 0 7 Second...

Страница 24: ...odes of operation Options are All functions volume tone diagnostics and reset Enable only volume tone and reset Enable reset only Disable all button functions Scanner Button Options All functions Scan...

Страница 25: ...l Take Picture operation Activates Cell Phone Toggle Mode when not taking picture Activates Cell Phone One Shot Mode when not taking pictures Camera Button Mode Normal Take Picture opera tion DEFAULT...

Страница 26: ...ithout user intervention For high ambient light conditions button cell phone mode is recommended See Camera Button Mode on page 17 Auto Cell Phone Mode Enable Enables disables Auto Cell Phone Mode Aut...

Страница 27: ...Enter Exit Programming Mode Product Reference Guide 19 LED Level This feature defines the LED intensity level by pulse width LED Level Medium LED Level Low LED Level High DEFAULT...

Страница 28: ...function associated with the auxillary interface Choices are Disabled 01 Serial Handheld Enabled 02 PIR CT Output plus Diagnostics Reporting Disable Auxiliary Port Mode DEFAULT Auxiliary Port Mode Ser...

Страница 29: ...of auxillary port when operating in PIR CT mode Auxiliary Port Baud Rate 1200 Auxiliary Port Baud Rate 2400 Auxiliary Port Baud Rate 4800 Auxiliary Port Baud Rate 9600 Auxiliary Port Baud Rate 19200 D...

Страница 30: ...ta before being presented to the POS The PIR feature allows the scanner to provide infor mation to an external computer indicating how easy the label was to read NOTE Disable DEFAULT Enable This value...

Страница 31: ...ct Reference Guide 23 Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode Disable Sleep Mode 15 Seconds 30 Seconds 1 Minute 2 Minutes 3 Min...

Страница 32: ...Enter Exit Programming Mode 24 Magellan 3200VSI Sleep Mode continued 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour...

Страница 33: ...enables the indication a single beep that the scanner has finished all its power up tests and is now ready for operation Disable Enable DEFAULT External Read Indicator ERI Active State High NOTE ERI A...

Страница 34: ...milliseconds 10ms or 0 01 sec onds To configure this feature scan the Enter Exit Programming Mode bar code above to place the unit in Pro gramming Mode then the Set ERI Timeout followed by the two dig...

Страница 35: ...green LED upon successfully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then activ NOTE This option Ind...

Страница 36: ...sables the scanner s ability to beep upon a successful decode of a bar code Disable Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high fre q...

Страница 37: ...Enter Exit Programming Mode Product Reference Guide 29 Good Read Beep Length Specifies the duration of a good read beep 60msec 80msec DEFAULT 100msec 120msec 140msec 160msec 180msec 200msec...

Страница 38: ...Enter Exit Programming Mode 30 Magellan 3200VSI Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels Low Medium High DEFAULT...

Страница 39: ...eatures Wake Up Intensity This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode Lower settings provide greater sensi tivity The select...

Страница 40: ...Enter Exit Programming Mode 32 Magellan 3200VSI Wake Up Intensity continued 13 14 15...

Страница 41: ...cial Label Insert a microSD card into the scanner scan a capture label and place the item to be captured in front of the scanner Press and release the Camera Button The image will be written to the mi...

Страница 42: ...VGA 752X480 2 SXGA 1280x1027 3 CIF 320x240 B brightness value in ASCII B uses scanner s configuration value CI_IMAGE_BRIGHTNESS else 0 thru 9 specifies brightness C contrast value in ASCII C uses scan...

Страница 43: ...f quality Follow these steps to program this feature 1 Scan the Enter Exit Programming Mode bar code 2 Scan the Set Image Compression bar code 3 Turn to and scan the two digits zero padded representin...

Страница 44: ...t Programming Mode 36 Magellan 3200VSI Image Size Specifies the size of the image capture Choices are VGA WVGA SXGA Full Size CIF Image Size VGA DEFAULT Image Size WVGA Image Size SXGA Full Size Image...

Страница 45: ...programming sequence by scanning the Enter Exit Pro gramming Mode bar code Set Image Brightness DEFAULT SETTING FOR THIS FEATURE 09 Image Contrast This feature sets the image contrast value Follow the...

Страница 46: ...Enter Exit Programming Mode 38 Magellan 3200VSI NOTES...

Страница 47: ...aces Supported RS 232 Page Keyboard Wedge RS 232 Standard 41 Keyboard Wedge Aa a Consult Table 2 on page 40 for more information regarding keyboard inter face types 41 RS 232 Wincor Nixdorf 41 Keyboar...

Страница 48: ...Encoding C PS 2 25 and 30 w Alternate Key Encoding D PC XT w Standard Key Encoding E AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding F PS 2 25 and 30 w Standard Key Encoding G IBM...

Страница 49: ...Programming Mode Product Reference Guide 41 Interface Selection RS 232 Standard RS 232 Wincor Nixdorf IBM 4683 Port 5B IBM 4683 Port 9B IBM 4683 Port 17 USB OEM USB Keyboard USB COM Interface Keyboar...

Страница 50: ...oard Wedge C Keyboard Wedge D Keyboard Wedge E Keyboard Wedge F Keyboard Wedge G 0 0 0 1 3 2 Keyboard Wedge H Keyboard Wedge I Keyboard Wedge J Enter Exit Programming Mode 42 Magellan 3200VSI Interfac...

Страница 51: ...Specifies the number of host transmission s that may be buffered By buffering data from a bar code the scanner can continue to read a new bar code while the old one is being transmitted to the host Se...

Страница 52: ...3200VSI RS 232 Interface Features NOTE Baud Rate 1200 Baud 2400 Baud 4800 Baud 9600 Baud DEFAULT 19200 Baud 38400 Baud 57600 Baud 115200 Baud A setting of no parity with 7 data bits is invalid and wi...

Страница 53: ...Enter Exit Programming Mode Product Reference Guide 45 RS 232 Interface Features continued Data Bits 7 Data Bits 8 Data Bits DEFAULT Stop Bits 1 Stop Bit DEFAULT 2 Stop Bits Parity Parity None DEFAUL...

Страница 54: ...nsmission of data to the host Enable CTS Scan Control The CTS line must be active for the scanner to read and transmit data While the CTS line is inactive the scanner remains in a host disabled state...

Страница 55: ...ed If the transmission speed is too high the system may not be able to receive all characters You may need to adjust the delay to make the system work properly Interchar Delay No Delay DEFAULT Interch...

Страница 56: ...y 90 msec Enter Exit Programming Mode 48 Magellan 3200VSI Intercharacter Delay continued Software Flow Control Disables Enables software control using XON XOFF characters Disable Software Flow Control...

Страница 57: ...e same cable is necessary If for example one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission...

Страница 58: ...he scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host Host Echo Quiet Interval 0msec Host Echo Quiet Interval 10msec DEFAULT Host Echo Quiet Int...

Страница 59: ...msec RS 232 Interface Features Enter Exit Programming Mode Product Reference Guide 51 Host Echo Quiet Interval continued Signal Voltage Normal TTL Specifies whether the RS 232 interface provides TTL l...

Страница 60: ...ert Beep on ASCII BEL Enables disables ability of scanner to beep sound a good read tone on receiv ing an ASCII BEL 07 hex Enable Beep on ASCII BEL DEFAULT Disable Beep on ASCII BEL Beep on Not on Fil...

Страница 61: ...when the data is in error Selections for this option are Disable Enable for label transmission the scanner expects an ACK NAK response from the host when a label is sent Enable for host command ackno...

Страница 62: ...ode by again scanning the Enter Exit Programming Mode bar code above DEFAULT SETTING FOR THIS FEATURE 006 Set ACK Character NAK Character Sets the NAK character from the set of ASCII characters or any...

Страница 63: ...ait for an ACK character from the host following a label transmission 00 Infinite timeout 01 75 Timeout in 200 millisecond increments To configure this feature scan the Enter Exit Programming Mode bar...

Страница 64: ...try count Exit programming mode by again scanning the Enter Exit Pro gramming Mode bar code above DEFAULT SETTING FOR THIS FEATURE 003 Set ACK NAK Timeout Value ACK NAK Error Handling This item specif...

Страница 65: ...Exit Programming Mode Product Reference Guide 57 Transmission Failure Indication Enables disables bad label indication upon transmission failure Disable Transmission Error Indication Enable Transmiss...

Страница 66: ...S 232 interfaces Rather than repeat them in this section as Single Cable options please find them referenced as follows RS 232 Baud Rate on page 2 44 RS 232 Number of Data Bits on page 2 45 RS 232 Num...

Страница 67: ...state and CTS is ignored Option 1 RTS is held in high state and CTS is ignored Option 2 Assert RTS and wait for CTS to be asserted Option 3 Assert RTS and ignore CTS Option 4 RTS held low wait for CT...

Страница 68: ...I Single Cable RS 232 Use BCC Enables disables the ability of the scanner to use BCC Disable BCC Enable BCC DEFAULT Single Cable RS 232 Use ACK NAK Enables disables the ability of the scanner to use A...

Страница 69: ...3 Scan the appropriate characters digits from the keypad in Appendix that represent the decimal designation for the desired character A table con taining the ASCII Character Set and their correspondi...

Страница 70: ...opriate characters digits from the keypad in Appendix that represent the decimal designation for the desired character A table con taining the ASCII Character Set and their corresponding decimal value...

Страница 71: ...Plus Enables disables sending Pacesetter Plus information as trailers to UPC EAN labels Disable Pacesetter Plus DEFAULT Enable Pacesetter Plus Single Cable Datalogic Extensions Enables Datalogic exten...

Страница 72: ...ices to communicate Options are Table Top Scanner Handheld Scanner Configure as Table Top Scanner DEFAULT Configure as Handheld Scanner IBM IBM Transmit Labels in Code 39 Format This feature enables d...

Страница 73: ...le process that doesn t require any changes of software or hardware NOTE All of the options in this section apply to the Keyboard Wedge however only Keyboard Layout some Caps Lock State Control Charac...

Страница 74: ...Enter Exit Programming Mode 66 Magellan 3200VSI USB Keyboard continued Italy Norway Portugal Spain Sweden Switzerland Japan 106 Key Hungary Czech Republic...

Страница 75: ...gramming Mode Product Reference Guide 67 Caps Lock State Specifies the format in which the scanner sends character data Disable Caps Lock DEFAULT Caps Lock ON Shift Lock ON USB Keyboard continued Slov...

Страница 76: ...interface All PCs check the keyboard status during the power on Selftest It is recom mended that you enable this function if you are working without a keyboard installation It simulates keyboard timin...

Страница 77: ...transmission of control characters to host Send characters between 00H and 1FH according to a special function key mapping table This is used to send keys that are not in the normal ASCII set a unique...

Страница 78: ...st Selectable from 001 to 100 in 10 msec increments To configure this feature scan the Enter Exit Programming Mode bar code above to place the unit in Programming Mode then the Set Wedge Quiet Interva...

Страница 79: ...your desired length Exit programming mode by again scanning the Enter Exit Program ming Mode bar code above DEFAULT SETTING FOR THIS FEATURE 00 No Delay Set Intercharacter Delay USB COM Interface Setu...

Страница 80: ...USB COM Interface Setup 72 Magellan 3200VSI NOTES...

Страница 81: ...Label ID Label ID Bar Code Data 00 20 Characters ASCII Label ID Transmission Enable this option to transmit the Label ID you configure for the scanned symbology AIM ID This function is used to identif...

Страница 82: ...ure scan the Enter Exit Programming Mode bar code above to place the unit in Programming Mode then the Set Prefix or Set Suffix followed by the digits from the Alphanumeric table in Appendix C represe...

Страница 83: ...consist of three characters as follows A close brace character ASCII followed by A code character see the table below followed by SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN E Code 128 EAN 128 C Code 39 A G...

Страница 84: ...Position After Bar Code Data Set UPC A Label ID Character s DEFAULT SETTING FOR THIS FEATURE A 41 hex DEFAULT SETTING FOR THIS FEATURE A 41 hex Set UPC A w P2 Addon Label ID Character s Set UPC A w P...

Страница 85: ...TURE E 45 hex Set UPC E w C128 Addon Label ID Character s Set EAN 8 Label ID Character s DEFAULT SETTING FOR THIS FEATURE FF 4646 hex DEFAULT SETTING FOR THIS FEATURE FF 4646 hex Set EAN 8 w P2 Addon...

Страница 86: ...ATURE F 46 hex Set EAN 13 w C128 Addon Label ID Character s Set ISBN Label ID Character s DEFAULT SETTING FOR THIS FEATURE I 49 hex 0 3 4 C DEFAULT SETTING FOR THIS FEATURE IA 4941 hex Set IATA Label...

Страница 87: ...TING FOR THIS FEATURE RX 5258 hex Set GS1 Expanded Label ID Character s Set Code GS1 DataBar Limited Label ID Character s DEFAULT SETTING FOR THIS FEATURE 524C0000 hex DEFAULT SETTING FOR THIS FEATURE...

Страница 88: ...Label ID Character s Set EAN UCC Composite Label ID Character s DEFAULT SETTING FOR THIS FEATURE 0 DEFAULT SETTING FOR THIS FEATURE P 5000 hex a a Default setting exceptions for PDF 417 Label ID are a...

Страница 89: ...ite Label ID Character s Set GS1 DataBar Limited 2D Composite Label ID Character s DEFAULT SETTING FOR THIS FEATURE RL 524C0000 hex DEFAULT SETTING FOR THIS FEATURE RX 52340000 hex Set GS1 DataBar Exp...

Страница 90: ...can convert scanned bar code data to either all lower case a through z or all upper case A through Z characters NOTE Disable DEFAULT Convert to Upper Case Convert to Lower Case Case conversion affects...

Страница 91: ...r the character conver sion BG25TB82 The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character Nothing is done with the last two char acter pair...

Страница 92: ...Enter Exit Programming Mode Character Conversion 84 Magellan 3200VSI NOTES...

Страница 93: ...92 Code 128 on page 109 EAN 8 on page 94 Interleaved 2 of 5 on page 112 GS1 DataBar Omnidirectional Stacked Omnidirectional on page 99 Codabar on page 114 GS1 DataBar Expanded Expanded Stacked on pag...

Страница 94: ...isable Enable UPC A When disabled the scanner will not read UPC A bar codes Disable UPC A Enable UPC A DEFAULT Check Digit Transmission Enable this option to transmit the check digit along with UPC A...

Страница 95: ...transmission of UPC A System Number Disable Number System Transmission Enable Number System Transmission DEFAULT Expand UPC A to EAN 13 Expands UPC A data to the EAN 13 data format Selecting this fea...

Страница 96: ...to the UPC E symbology Disable Enable UPC E When disabled the scanner will not read UPC E bar codes Disable UPC E Enable UPC E DEFAULT Check Digit Transmission Enable this option to transmit the chec...

Страница 97: ...can be optionally included or not with scanned bar code data Exclude Number System Digit DEFAULT Include Number System Digit 0 2 4 8 0 1 Expand to UPC E to UPC A Enables disables expansion of UPC E la...

Страница 98: ...AN 13 Selecting this feature also changes the symbology ID to match those required for EAN 13 Don t Expand UPC E to EAN 13 DEFAULT Expand UPC E to EAN 13 UPC EAN Quiet Zone This feature sets a Quiet Z...

Страница 99: ...erence Guide 91 GTIN The following options apply to the GTIN label data format Expand UPC EAN to GTIN When this feature is enabled the scanner will translate UPC EAN labels to the 14 digit GTIN format...

Страница 100: ...o the EAN 13 symbology Disable Enable EAN 13 When disabled the scanner will not read EAN 13 bar codes Disable EAN 13 Enable EAN 13 DEFAULT Check Digit Transmission Enable this option to transmit the c...

Страница 101: ...EAN 13 Flag 1 Char DEFAULT ISBN When enabled this feature truncates the leading three digits from labels that contain ISBN International Standard Book Number and appends an ISBN check character to th...

Страница 102: ...isable EAN 8 Enable EAN 8 DEFAULT Check Digit Transmission Enable this option to transmit the check Digit along with EAN 8 bar code data Don t Send Check Digit Send Check Digit DEFAULT Expand EAN 8 to...

Страница 103: ...he ability of the scanner to decode EAN two label pairs Disable EAN Two Label Enable EAN Two Label EAN Two Label Combined Transmission Enables disables the transmitting of an EAN two label pair as one...

Страница 104: ...options for this feature Disable Enable 4 digit price wt check digit calculation Enable 5 digit price wt check digit calculation Enable European 4 digit price weight check digit calculation Enable Eu...

Страница 105: ...ons Supported options are None This option directs the scanner to ignore add on portion of a UPC EAN bar code but still read the main portion of the bar code 2 Digits The scanner will optionally read...

Страница 106: ...onal 2 Digit Add ons Disable Optional 5 Digit Add ons DEFAULT Enable Optional 5 Digit Add ons 0 1 1 0 1 Disable Optional Code 128 Add ons DEFAULT Enable Optional Code 128 Add ons Enter Exit Programmin...

Страница 107: ...symbology Disable Enable GS1 DataBar Omnidirectional When this feature is disabled the scanner will not read GS1 DataBar Omnidirec tional bar codes Disable GS1 DataBar Omnidirectional DEFAULT Enable G...

Страница 108: ...nded symbology Disable Enable GS1 DataBar Expanded When this feature is disabled the scanner will not read GS1 DataBar Expanded bar codes Disable GS1 DataBar Expanded DEFAULT Enable GS1 DataBar Expand...

Страница 109: ...the scan ner will decode a bar code if the label length falls in the range of the configu rable Length 1 and Length 2 values Variable Length Decoding DEFAULT Fixed Length Decoding GS1 DataBar Expande...

Страница 110: ...anded Stacked 102 Magellan 3200VSI Coupon Read Control This feature controls coupon reading Disable coupon filtering Enable UPCA coupon decoding Disable GS1 DataBar coupon decoding DEFAULT Enable GS1...

Страница 111: ...gy Disable Enable GS1 DataBar Limited When this feature is disabled the scanner will not read GS1 DataBar Limited bar codes Disable GS1 DataBar Limited DEFAULT Enable GS1 DataBar Limited GS1 128 Emula...

Страница 112: ...s feature is disabled the scanner will not read Code 39 bar codes Disable Code 39 Enable Code 39 DEFAULT Check Character Calculation When enabled the scanner will calculate the check character of the...

Страница 113: ...option to transmit the check character with scanned bar code data Disable Check Char Transmission Enable Check Char Transmission DEFAULT Start Stop Characters Enables disables transmission of Code39 s...

Страница 114: ...rogramming Mode Code 39 106 Magellan 3200VSI Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters Disable Code 39 Full ASCII DEFAULT Enable Code 3...

Страница 115: ...the label length falls in the range of the configu rable Length 1 and Length 2 values Variable Length Decoding DEFAULT Fixed Length Decoding Code 39 Length 1 Length 2 Programming Instructions See Len...

Страница 116: ...32 Italian Pharma code bar codes Disable Code 32 Italian Pharmacode DEFAULT Enable Code 32 Italian Pharmacode Start Stop Characters Enables or disables transmission of Code 32 Italian Pharmacode start...

Страница 117: ...to the Code 128 symbology Disable Enable Code 128 When this feature is disabled the scanner will not read Code 128 bar codes Disable Code 128 Enable Code 128 DEFAULT Disable Enable EAN 128 When this f...

Страница 118: ...on Characters DEFAULT Transmit Function Characters Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the...

Страница 119: ...on page 148 for detailed instructions on setting this feature NOTE DEFAULT SETTING FOR THIS FEATURE 01 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 80 For Code 128 bar codes only the dat...

Страница 120: ...will not read Interleaved 2 of 5 bar codes Disable Interleaved 2 of 5 DEFAULT Enable Interleaved 2 of 5 Check Digit Calculation When enabled the scanner will calculate the check digit of the labels D...

Страница 121: ...de if the label length falls in the range of the configu rable Length 1 and Length 2 values Variable Length Decoding DEFAULT Fixed Length Decoding Interleaved 2 of 5 Length 1 Length 2 Programming Inst...

Страница 122: ...ology Disable Enable Codabar When this feature is disabled the scanner will not read Codabar bar codes Disable Codabar DEFAULT Enable Codabar Check Character Verification When enabled the scanner will...

Страница 123: ...ULT Codabar Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable fixed lengths Variable Len...

Страница 124: ...FAULT SETTING FOR THIS FEATURE 03 Set Length 1 Set Length 2 DEFAULT SETTING FOR THIS FEATURE 50 For Codabar bar codes all start stop check and data characters are included in the length calculations S...

Страница 125: ...of start and end characters of Codabar is selected below Disable Start Stop Char Transmission Enable Start Stop Char Transmission DEFAULT Start Stop Character Match This feature enables disables the r...

Страница 126: ...Enable Code 93 Length Control Fixed Length Decoding When fixed length decoding is enabled the scanner will decode a bar code if the label length matches one of the configurable fixed lengths Variable...

Страница 127: ...ctions 1 See Length 1 Length 2 Programming Instructions on page 148 for detailed instructions on setting this feature NOTE DEFAULT SETTING FOR THIS FEATURE 01 Set Length 1 Set Length 2 DEFAULT SETTING...

Страница 128: ...Disable Enable MSI When this feature is disabled the scanner will not read MSI bar codes Disable MSI DEFAULT Enable MSI MSI Check Character Transmit Enable this option to transmit the check character...

Страница 129: ...ptional MSI check characters When disabled any check characters in an MSI label are treated as data charac ters Disable Check Character Calculation Enable Check Character Calculation DEFAULT MSI Numbe...

Страница 130: ...le length decoding is enabled the scan ner will decode a bar code if the label length falls in the range of the configu rable Length 1 and Length 2 values Variable Length Decoding DEFAULT Fixed Length...

Страница 131: ...2D symbologies bar code types listed below Avail able options for each 2D symbology are included in this chapter PDF 417 on page 124 Maxicode on page 136 Micro PDF 417 on page 127 Aztec on page 139 Da...

Страница 132: ...the scanner will not read PDF 417 bar codes Disable PDF 417 Enable PDF 417 DEFAULT Allow Zero Length PDF 417 Reading This enables disables the scanner s ability to read PDF417 bar codes contain ing a...

Страница 133: ...g the Enter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0...

Страница 134: ...to Appendix C and scan the four digits zero padded representing the length NOTE For PDF 417 bar codes only the data characters are included in the length calculations Any value set higher than 2710 w...

Страница 135: ...Enter Exit Programming Mode Product Reference Guide 127 Micro PDF 417 Disable Enable Micro PDF 417 When disabled the scanner will not read Micro PDF 417 bar codes Disable Micro PDF 417 DEFAULT Enable...

Страница 136: ...nter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000 if...

Страница 137: ...e 3 Turn to Appendix C and scan the four digits zero padded representing the length NOTE For Micro PDF 417 bar codes only the data characters are included in the length calculations Any value set high...

Страница 138: ...nter Exit Programming Mode Datamatrix 130 Magellan 3200VSI Datamatrix Disable Enable Datamatrix When disabled the scanner will not read Datamatrix bar codes Disable Datamatrix Enable Datamatrix DEFAUL...

Страница 139: ...the Enter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 00...

Страница 140: ...urn to Appendix C and scan the four digits zero padded representing the length NOTE For Datamatrix bar codes only the data characters are included in the length calculations Any value set higher than...

Страница 141: ...QR Code Enter Exit Programming Mode Product Reference Guide 133 QR Code Disable Enable QR Code When disabled the scanner will not read QR Code labels Disable QR Code DEFAULT Enable QR Code...

Страница 142: ...he Enter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0000...

Страница 143: ...Turn to Appendix C and scan the four digits zero padded representing the length NOTE For 2d Code labels only the data characters are included in the length calculations Any value set higher than 2710...

Страница 144: ...Enter Exit Programming Mode Maxicode 136 Magellan 3200VSI Maxicode Disable Enable Maxicode When disabled the scanner will not read Maxicode labels Disable Maxicode DEFAULT Enable Maxicode...

Страница 145: ...g the Enter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 0...

Страница 146: ...urn to Appendix C and scan the four digits zero padded representing the length NOTE For Maxicode labels only the data characters are included in the length calculations Any value set higher than 138 w...

Страница 147: ...Aztec Enter Exit Programming Mode Product Reference Guide 139 Aztec Disable Enable Aztec When disabled the scanner will not read Aztec labels Disable Aztec DEFAULT Enable Aztec...

Страница 148: ...the Enter Exit Pro gramming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions below 5 Set Length 2 to the second fixed length or to 000...

Страница 149: ...Turn to Appendix C and scan the four digits zero padded representing the length NOTE For Aztec labels only the data characters are included in the length calculations Any value set higher than 3700 wi...

Страница 150: ...ansmitted regardless of the state of the linkage flag Disable GS1 DataBar Omnidirectional 2D Component DEFAULT Enable GS1 DataBar Omnidirectional 2D Component Disable Enable GS1 DataBar Expanded 2D Co...

Страница 151: ...imited label is decoded which has the 2D link age flag set the 2D component must also be decoded or the base label will be discarded When disabled only the GS1 DataBar Limited base label will be decod...

Страница 152: ...rse Label Reading This controls the method of reading inverse labels white label on black back ground NOTE 2D Read Mode Reads only normal labels DEFAULT 2D Read Mode Reads both normal and inverse labe...

Страница 153: ...ions Prefix Suffix AIM ID Label ID Label ID Bar Code Data 00 20 Characters ASCII AND OR OR Example Setting a Prefix In this example we ll set a prefix for all symbologies 1 Determine which ASCII chara...

Страница 154: ...hing When set to one it appends the symbol ogy s AIM ID to the Label ID NOTE When the control character is set to 01 for UPC A and UPC E it expands the label to EAN 13 and thus follows the EAN 13 Labe...

Страница 155: ...Length Decoding bar code for the desired symbology 3 Scan the Enter Exit Programming Mode bar code 4 Set Length 1 to the first fixed length by following the Length 1 Length 2 Programming Instructions...

Страница 156: ...et Length 2 bar code for the desired sym bology 3 Turn to Appendix C and scan the two digits zero padded representing the length in decimal notation The number of characters that can be set varies dep...

Страница 157: ...ad Performance Parameters Parameter Specification Scan Volume 250 cubic inches Minimum Resolution 5 mil Depth of Field 100 UPC Labels 0 8 0 20 32cm Minimum Print Contrast Ratio 25 Skew Yaw 75 Pitch 65...

Страница 158: ...4 V DC Operating Current and Power at 12V DC Current Power Maximum Inrush 715mA 8 6 Watts Maximum Continuous 545mA 6 6 Watts Nominal Scanner Only 180mA 2 2 Watts Sleep Scanner Only 123mA 1 5 Watts Env...

Страница 159: ...es a bar code has been read and decoded Scanner Ready Constant dim green The scanner is ready for operation The LED is also configu rable to off when idle and ready for operation Sleep Mode Green LED...

Страница 160: ...indication is configurable Options include Enable disable frequency duration and volume See LED and Beeper Indicators on page 2 25 for more information Diagnostics Varies see Error Codes on page 4 fo...

Страница 161: ...able Pinouts Primary Interface Cables DTR PCCLK CTS VBUS VBUS RTS Line B D D KBCLK RxD TxD Line A D D PC Data VCC in VCC in 12V VCC in VCC in GND GND GND GND GND KBD Pin RS 232 IBM Port 5B 9B 17 USB O...

Страница 162: ...1 2 AUX_CTS 3 4 AUX_RTS 5 AUX_RxD 6 AUX_TxD 7 AUX_ERI 8 VCC 9 GND 10 154 Magellan 3200VSI Cable Pinouts Handheld Scanner Attached via the Aux Port PIN HANDHELD ATTACHED TO AUX PORT...

Страница 163: ...Product Reference Guide 155 Appendix C A B C D E F Alpha Numeric Pad...

Страница 164: ...1 2 3 4 5 6 7 8 9 0 156 Magellan 3200VSI NOTE For numeric entry sequences the scan ner will announce the number of digits remaining to be entered after each label read...

Страница 165: ...l tone and reset Enable only vol tone and reset Camera Button Mode on page 17 Normal Take Pix Normal Take Pix Normal Take Pix Normal Take Pix Normal Take Pix Normal Take Pix LED Level on page 19 Defau...

Страница 166: ...ble Disable Disable Disable Disable Host Echo on page 49 Disable Disable Disable Disable Disable Disable Host Echo Quiet Interval on page 50 10 msec 10 msec 10 msec 10 msec 10 msec 10 msec Signal Volt...

Страница 167: ...Single Cable RS 232 ETX Character on page 62 0D Single Cable Pacesetter Plus on page 63 Disable Single Cable Datalogic Exten sions on page 63 Disable USB OEM Interface Features on page 64 Config as t...

Страница 168: ...Enable Enable Enable Enable Check Digit Transmission on page 88 Send Send Send Send Send Send Number System Digit on page 89 Exclude Exclude Exclude Exclude Exclude Exclude Expand to UPC E to UPC A on...

Страница 169: ...01 74 Coupon Read Control on page 102 Enable UPCA Disable GS1 DataBar Enable UPCA Disable GS1 DataBar Enable UPCA Dis able GS1 DataBar Enable UPCA Disable GS1 DataBar Enable UPCA Disable GS1 DataBar...

Страница 170: ...Disable Disable Disable Disable Disable Check Digit Transmit on page 112 Disable Disable Disable Disable Disable Disable Interleaved 2 of 5 Length Con trol on page 113 Variable 06 50 Variable 06 50 Va...

Страница 171: ...ble 0001 0366 Variable 0001 0366 Variable 0001 0366 Variable 0001 0366 Variable 0001 0366 Disable Enable Datamatrix on page 130 Disable Disable Disable Disable Disable Disable Datamatrix Length Contro...

Страница 172: ...nent on page 142 Disable Disable Disable Disable Disable Disable Disable Enable GS1 DataBar Limited 2D Component on page 143 Disable Disable Disable Disable Disable Disable Inverse Label Reading on pa...

Страница 173: ...C XT Scan Set 1 No No AT PS 2 25 286 PS 2 30 286 PS 2 50 50Z PS 2 60 70 80 90 95 Foreign ALT Mode Wedge B AT PS2 Scan Set 2 No No PS 2 25 and 30 Foreign ALT Mode Wedge C AT PS2 Scan Set 1 No No PC XT...

Страница 174: ...ad 00h 4Fh 0B VT TAB left 02h 2Bh 0C FF Enter right keypad 00h 58h 0D CR CR 00h 28h 0E SO INSERT inner keypad 00h 49h 0F SI PAGE UP inner keypad 00h 4Bh 10 DLE PAGE DOWN inner keypad 00h 4Eh 11 DC1 HO...

Страница 175: ...C4 UP arrow inner keypad 48h E0 Scanset 1 Function Key Map Table 5 Scanset 2 Function Key Map ASCII hex ASCII code Key Scancode 02 STX ALT left Make 11h 03 ETX ALT left Break F0h 11h 04 EOT CTRL left...

Страница 176: ...t 0Dh S 0C FF Enter inner keypad 79h 0D CR CR 5Ah 0E SO INSERT inner keypad 67h 0F SI PAGE UP inner keypad 6Fh 10 DLE PAGE DOWN inner keypad 6Dh 11 DC1 HOME inner keypad 6Eh 12 DC2 LEFT arrow inner ke...

Страница 177: ...h 0A LF RIGHT arrow inner keypad 6Ah 0B VT TAB left 0Dh S 0C FF CR FIELD EXIT Make only 5Ah F0h 5Ah 0D CR CR FIELD EXIT Make Break 5Ah 0E SO INSERT inner keypad 65h 0F SI FIELD 79h 10 DLE FIELD 7Ch 11...

Страница 178: ...4Dh 0Bh VT TAB left 3Ch S 0Ch FF Enter right keypad 60h 0Dh CR CR 3Bh 0Eh SO INSERT inner keypad 52h 0Fh SI PAGE UP inner keypad 49h 10h DLE PAGE DOWN inner keypad 51h 11h DC1 HOME inner keypad 4Ch 1...

Страница 179: ...HT TAB right 0Fh 0Ah LF RIGHT arrow inner keypad 3Ch 0Bh VT TAB left 0Fh S 0Ch FF DELETE 39h 0Dh CR CR 1Ch 0Eh SO INSERT inner keypad 38h 0Fh SI KATAKANA LOCK ON Make 72h 10h DLE KATAKANA LOCK OFF Br...

Страница 180: ...172 Magellan 3200VSI NOTES...

Страница 181: ...rce Good Read Tone 0x01 Beeps regardless of beep setting Identification request i 0x69 Returns long responsea a Call Tech Support for information Health request h 0x68 Returns long responsea Status re...

Страница 182: ...174 Magellan 3200VSI NOTES...

Страница 183: ...t Reference Guide 175 Appendix G Sample Symbols 1D Symbol Samples 0 1234567890 UPC A 0 5 1234567890 Interleaved 2 of 5 Code 128 Code 128 9 780330 290951 EAN 13 BC321 Code 39 A13579B Codabar 123456 9 C...

Страница 184: ...176 Magellan 3200VSI 0100123456789050 GS1 DataBar Expanded 01 00123456789012 GS1 DataBar Omnidirectional 123456 Code 2 of 5 01 16543210987654 GS1 DataBar Limited...

Страница 185: ...Product Reference Guide 177 2D Sample Symbols A12B3C BV17453 1314H17LL PDF 417 Micro PDF 417 Datamatrix QR Code 35900G9 Maxicode Aztec This is an Aztec Code MaxicodeMode4...

Страница 186: ...178 Magellan 3200VSI Composite Sample Symbols GS1 DataBar Limited Composite GS1 DataBar Truncated Composite...

Страница 187: ...file naming format i e FILENAME EXT and MUST be capitalized microSD Card Insertion 1 Read all of these instruc tions before starting Back Cover Optional Back Cover Stand Assembly 2 If you have not alr...

Страница 188: ...al 1 Push in gently using your finger or thumbnail to disengage and remove the microSD card Remember to keep your finger in place atop the card s edge to avoid accidentally launching the card from the...

Страница 189: ...the Capture Label The scanner enters image capture mode 3 Place the item to be captured in front of the scanner Press and release the Camera Button The scanner will automatically cap ture and save th...

Страница 190: ...TXT is saved to the microSD card Export Scanner Status to microSD card The data includes scanner ID statistics and scanner health By scanning a label 1 Insert the microSD card into the scanner 2 Scan...

Страница 191: ...the microSD card 3 Insert the microSD card into the scanner 4 Upon scanner audio indication of completion the application code R96 APP1 BIN is loaded to the scanner Typically this takes about 45 secon...

Страница 192: ...184 Magellan 3200VSI NOTES...

Страница 193: ...ndheld Symbologies requiring fixed lengths UPC EAN will enforce length requirements for validation of the label Handheld will be required to transmit start and stop characters for Cod abar and Code 39...

Страница 194: ...umber system must be included in label data Check digit must be included in label data and is assumed to be correct Supplemental data is appended to base label Prefix must be an ASCII character A tota...

Страница 195: ...UPC E with 5 Digit Supplemental Number system must be included in label data Check digit must be included in label data and is assumed to be correct Prefix must be an ASCII character E total length in...

Страница 196: ...ntal data is appended to base label Prefix must be an ASCII characters FF total length including prefix must be greater than 16 code 128 Supplemental codes are variable length hav ing a minimum of 2 d...

Страница 197: ...in scanner s fixed or variable label length control for this symbology type Start and stop characters must be included in label Prefix must be an ASCII character Example Code 39 TEST Code 39 Pharmacod...

Страница 198: ...el Example s 99 95s the lower case s at each end of the example is a placeholder for the start stop character set Code 128 Prefix must be an ASCII character Label length excluding prefix character or...

Страница 199: ...9254 Code 93 Prefix must be an ASCII character Label length excluding prefix character must meet requirements imposed by the main scanner s fixed or variable label length control for this sym bology t...

Страница 200: ...mis sion format labels will be transmitted as EAN 13 Example E00000000998875 EAN 13 Check digit must be included in label data and is assumed to be correct Prefix must be ASCII characters E0 total len...

Страница 201: ...prefix must be 8 Total required length is 24 for EAN 13 and 19 for EAN 8 Examples addon portion is highlighted data is underlined UPC A 5 Digit addon E00060992011187 E212345 UPC E 5 Digit addon E00000...

Страница 202: ...cluding start stop and check characters and excluding pre fix characters must meet requirements imposed by the main scanner s fixed or variable label length control for this symbology type Start and s...

Страница 203: ...mum length is the maximum label size supported by the scanner Example e001900123456789083103001750 I 2 of 5 Check character must be included in label data Label length including check characters and e...

Страница 204: ...l length control for this symbology type Example L0pdf_test_label Unknown AIM ID an AIM ID which is not specified above If a label is received that does not have an AIM ID as specified above and the f...

Страница 205: ...32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d...

Страница 206: ...Datalogic S p A and its Group companies All rights reserved Protected to the fullest extent under U S and international laws Copying or altering of this document is prohibited without express written...

Отзывы: