DATA FORMAT
2.7.2
Symbology Dependent Parameters
The “Symbology Specific Format Default” code on page 41 allows restoring the
symbology dependent parameters related to a specific code family to the default
values.
C
USTOM
C
ODE
I
DENTIFIER
Custom Code Identifier
AOCPBLHMHNGNENEIEPANHOGOCK
AHPNIJAMDKEOFMHMLJALEHFHIK
AKCBPJCJGIIJCMCFGJLLDNBJNK
AEFBJLBGMHPKNOGANCECFEMGGK
AAPHBAJIDDGNCMJCAFDEFOFNHK
AEKFALLKNIIMEADJNKJEAODLJK
DLDLLLLDDDLLLLLDLLLDDLDLLL
1. Select a Datalogic Standard Code
Identifier from the Code Identifier
Table in Appendix B.
2. Set the number of characters in the
range
0-3
, where
0
= Code ID
disabled.
3. Read the corresponding characters as
Hex values from the Hex/Numeric
table. Valid values are in the range
00-7F.
S
YMBOLOGY
S
PECIFIC
F
ORMAT
Symbology Specific Format
AOCLCIHOFNGNENEIEPANHOGOCK
AHPNIBAMDKEOFMHMLJAKEGHGIK
AKCBPJCJGIIJCMCFHLNMJCGPLK
AEFBJLBGMHPLMMGPEPDOAPMGGK
AAPHBAJJDCFMDNCMBONAPKCNHK
AGKFALICLLGKIBEJGFOCKENJLK
DLLLLLDLLLDLLLLDDLDDDLDLLL
1. Select a Datalogic Standard Code
Identifier from the Code Identifier
Table in Appendix B.
2. Formatting:
0 = select all - Stop
1
=
select right - followed by Step 3
2
= select left - followed by Step 3
3
= select middle - followed by a
number in the range
000-999
for the starting character and
then,
by
Step 3
4
= discard right - followed by Step 3
5
= discard left - followed by Step 3
6
= discard middle - followed by a
number in the range
000-999
for the starting character and
then,
by
Step 3
3. Set the number of characters to
select/discard in the range
000-999
.
38
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]