HOST CONFIGURATION STRINGS
A
ADVANCED IMAGE CAPTURE (GUN)
DESCRIPTION STRING
IMAGE PRESET 4
Basic Configuration
Image Format
Bitmap format
IDA0
JPEG
format
IDA1
TIFF
format
IDA2
Resolution
full resolution (640x480)
IDB0
quarter resolution (320x240)
IDB1
JPEG Quality Factor
IDCg
Advanced Configuration
Window Dimensions
origin along X axis
IDIh
origin along Y axis
IDLh
width
IDMh
height
IDNh
Brightness increase
IDO0IDFi
decrease
IDO1IDF1i
Contrast increase
IDP0IDEi
decrease
IDP1IDEi
Zoom 20%
IDH0
40%
IDH1
60%
IDH2
80%
IDH3
100%
IDH4
120%
IDH5
140%
IDH6
160%
IDH7
180%
IDH8
200%
IDH9
Color Depth
2 gray levels
IDG0
16 gray levels
IDG1
256 gray levels
IDG2
g, h, i
= a number from the HEX/Numeric Table
g
= a number in the range 000-100
h
= for X axis a number in the range 0-630
for Y axis a number in the range 0-470
for width a number in the range 10-640
for height a number in the range 10-480
i
= a number in the range 0-100