Enter/Exit Programming Mode
76
Gryphon™ I GD44XX/GBT4400/GM440X
Wand Signal Speed
This feature specifies the speed of the Wand output signal per nominal bar
or space. Choices are:
• 330 microseconds
• 660 microseconds
$CWASP00(CR)
Wand Signal Speed = 330ms
$CWASP01(CR)
Wand Signal Speed = 660ms
Wand Polarity
This option specifies the polarity of the Wand output signal. Choices are:
• Quiet zones and spaces are high, bars are low
• Quiet zones and spaces are low, bars are high
$CWAPO00(CR)
Wand Polarity = Quiet Zones & Spaces High, Bars Low
$CWAPO01(CR)
Wand Polarity = Quiet Zones & Spaces Low, Bars High
TTL logic levels:
0V <= Low <= 0.7V
2.4V <= High <= 5.25V
DEFAULT