Enter/Exit Programming Mode
74
Gryphon™ I GD44XX/GBT4400/GM440X
Transmit Labels in Code 39 Format
This feature enable/disables translation to Code 39 before transmitting
label data to an IBM-46XX or a USB-OEM host. Only the symbology identifier
is modified for the translation. The data is not converted to Code 39 or ver-
ified to be valid for Code 39.
Options are:
IBM Standard Format:
Send labels in standard IBM format.
Code 39 Format:
Translate the following symbologies to Code 39:
• USB-OEM: Code128, Code 93, and Codabar
• IBM-Port 5B: Code 128, Code 93, and Codabar
• IBM-Port 9B: Code 93 and Codabar
$CIBC300(CR)
Transmit Labels in Code 39 Format =
IBM Standard Format
$CIBC301(CR)
Transmit Labels in Code 39 Format = Code 39 Format
Interface Options
$CIFO101(CR)
Obey Scanner Configuration Host Commands
$CIFO102(CR)
Ignore Scanner Configuration Host Commands
This feature provides for an interface-specific control mechanism.
DEFAULT
DEFAULT
Содержание Gryphon I GM440 Series
Страница 42: ...Setup 32 Gryphon I GD44XX GBT4400 GM440X...
Страница 46: ...Enter Exit Programming Mode 36 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 60: ...Enter Exit Programming Mode 50 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 102: ...Enter Exit Programming Mode 92 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 248: ...238 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 308: ...References 298 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 338: ...Keypad 328 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Страница 348: ...Scancode Tables 338 Gryphon I GD44XX GBT4400 GM440X NOTES...