Technical Features
Quick Reference Guide
19
RS-232 Electrical Connections
Default configuration is RS-232: 9600, 8, N, 1, no handshaking, ACK/NAK disabled.
Storage Temperature
-4° to 158° F (-20° to 70° C)
Humidity
Operating: 5% to 90% relative humidity, non condensing
Drop specifications
5 drops from 30 inches (0.76 mt.) to concrete
Ambient Light immunity
Up to 100,000 Lux
Contaminants
IEC529-IP54
ESD Level
12 KV
Regulatory
LED Emission Class
(IEC-62471:2006-07) Exempt (No Risk)
IEC60825-1: 2007
Electrical Safety
IEC 60950-1 , CAN/CSA C22.2 No. 60950-1-07; UL 60950-1
EMI/RFI
North America (FCC) : Part 15 Class B, Canada ( IC) :
ICES-003 Class B, European Union EMC Directive, Australian
(C-tick), Russia (Gost)
9-pin connector
1
Trigger
Trigger signal input (see
Figure 2
and
Figure 3
on next page)
2
TX
Transmit Data (output from scanner)
3
RX
Receive Data (input to scanner)
4
NC
Not connected
5
GND
Ground
6
VCC
+5Vdc
7
CTS
Clear To Send (input to scanner)
8
RTS
Request To Send (output from scanner)
9
DIGITAL OUTPUT Output signal (see
Figure 1
)