Enter/Exit Programming Mode
1D Code Selection
152
Gryphon™ I GD44XX
/
GBT4400
I 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for
maximum label length if in
Mode, or the second fixed length if in
Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).
provides examples for setting Length 2. See
for detailed instructions on setting
this feature.
Table 8. I 2 of 5 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This
Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L2
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Содержание Gryphon I GD44XX
Страница 1: ...Gryphon I GD44XX GBT4400 General Purpose Handheld Area Imager Bar Code Reader Product Reference Guide...
Страница 40: ...Enter Exit Programming Mode 38 Gryphon I GD44XX GBT4400 NOTES...
Страница 54: ...Enter Exit Programming Mode 52 Gryphon I GD44XX GBT4400 NOTES...
Страница 63: ...Product Reference Guide 61...
Страница 64: ...62 Gryphon I GD44XX GBT4400...
Страница 232: ...228 Gryphon I GD44XX GBT4400 NOTES...
Страница 294: ...290 Gryphon I GD44XX GBT4400 NOTES...
Страница 308: ...Sample Barcodes 304 Gryphon I GD44XX GBT4400 Sample Barcodes continued A020096020 Code 32 Codabar Code 93 Code 11...
Страница 312: ...308 Gryphon I GD44XX GBT4400 A B C D E F...
Страница 322: ...318 Gryphon I GD44XX GBT4400 NOTES...