SCANNING FEATURES
PRODUCT REFERENCE GUIDE
241
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a label, when
in trigger single mode. The range for this setting is from 1 to 255 seconds in 1-second
increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 =
005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent the
duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 25 for some examples of how to set this fea-
ture.
Table 18 Aiming Duration Time Setting Examples
NOTE: If you make a mistake before the last character, scan the CANCEL
bar code to abort and not save the entry string. You can then start again at
the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec.
(1.5 min.)
180 Sec.
(3 min.)
255 Seconds
(4.25 min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT AIMING DURATION TIME SETTING
5
Scan three characters from
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Gryphon GBT4200
Страница 14: ...PREFACE xiv GRYPHON I GD GBT GM4200 NOTES ...
Страница 92: ...78 GRYPHON I GD GBT GM4200 CONFIGURATION IBM 46XX INTERFACE SECTION CONTENTS IBM 46xx Interface Options ...
Страница 287: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 273 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231 ...
Страница 290: ...KEYPAD 276 GRYPHON I GD GBT GM4200 1 2 3 4 5 6 7 8 9 ...
Страница 303: ......