MOTION FEATURES
ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
109
MOTION FEATURES
Motionless Timeout
The period of time that must expire without detecting any motion, before the scanner is
assumed to be in a motionless condition. The selectable setting is from 500 to 25,500
milliseconds in 100 millisecond increments. This option relates to such features as the
Stand Mode/Object Detection scanning with respect to motion.
Motion Sensitivity
Sets the sensitivity level for motion detection wakeup. Choices are low, medium and
high.
Select Motionless Timeout
$CMOTO
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
14 = Motionless Timeout for 2 seconds
$CMOSY00
Motion Sensitivity = Low
Motion Sensitivity = Medium
$CMOSY01
$CMOSY02
Motion Sensitivity = High