background image

PREFACE

xiv

   GRYPHON™ I GD/GBT/GM4200

NOTES

Содержание Gryphon GBT4200

Страница 1: ...L Gryphon I GD GBT GM4200 PRODUCT REFERENCE GUIDE General Purpose Linear Bar Code Reader Corded or with Bluetooth Wireless Technology or Datalogic s STAR Cordless System ...

Страница 2: ...estions about this or other Datalogic publications please let us know via the Contact page Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accu rate however Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Dat...

Страница 3: ...SB Connection 6 Stand Installation 8 Hands Free Stand Holder 8 Setting Up the Gryphon gbt gm4200 Reader 9 Positioning the Base Station 10 Base Station Positions and Related Clips to be Used 10 Vertical Mount Adapter 12 Reader Cradle and LEDs Description 14 Connecting the Base Station 15 Base Station Connection and Routing 15 Securing the Cable Optional 16 Host Connection 16 Disconnecting the Cable...

Страница 4: ...E FEATURES 33 Host Commands Obey Ignore 33 USB Suspend Mode 33 RS 232 INTERFACE 34 RS 232 STANDARD SETTINGS 35 Baud Rate 35 Data Bits 36 Stop Bits 36 Parity 37 Handshaking Control 38 RS 232 USB COM INTERFACES 39 RS 232 USB COM SETTINGS 40 Intercharacter Delay 40 Beep On ASCII BEL 41 Beep On Not on File 41 ACK NAK Options 42 ACK Character 43 NAK Character 43 ACK NAK Timeout Value 44 ACK NAK Retry C...

Страница 5: ... Off Time 98 Corded Stand Mode 98 BEEPER CONTROL 99 Power On Alert 99 99 Good Read Beep Type 99 Good Read Beep Frequency 100 Good Read Beep Length 101 Good Read Beep Volume 102 LED CONTROL 103 RGB Good Read Enable 103 RGB Good Read Color 103 Good Read LED Duration 104 Good Read When to Indicate 105 Green Spot Duration 106 Illuminator Intensity Power Level 106 CAMERA CONTROL 107 Aiming Pointer 107 ...

Страница 6: ...130 GS1 DATABAR LIMITED 131 GS1 DataBar Limited Enable Disable 131 GS1 DataBar Limited to GS1 128 Emulation 131 CODE 39 132 Code 39 Enable Disable 132 Code 39 Check Character Calculation 132 Code 39 Check Character Transmission 133 Code 39 Start Stop Character Transmission 133 Code 39 Full ASCII 134 Code 39 Quiet Zones 134 Code 39 Length Control 135 Code 39 Set Length 1 135 Code 39 Set Length 2 13...

Страница 7: ... 1 155 Compressed 2 of 5 Set Length 2 155 DATALOGIC 2 OF 5 156 Datalogic 2 of 5 Enable Disable 156 Datalogic 2 of 5 Check Character Calculation 156 Datalogic 2 of 5 Check Character Transmission 157 Datalogic 2 of 5 Length Control 157 Datalogic 2 of 5 Set Length 1 158 Datalogic 2 of 5 Set Length 2 158 INDUSTRIAL 2 OF 5 159 Industrial 2 of 5 Enable Disable 159 Industrial 2 of 5 Check Character Calcu...

Страница 8: ...SI 182 MSI Enable Disable 182 MSI Check Character Calculation 182 MSI Check Character Transmission 183 MSI Length Control 183 MSI Set Length 1 184 MSI Set Length 2 184 PLESSEY 185 Plessey Enable Disable 185 Plessey Check Character Calculation 185 Plessey Check Character Transmission 186 Plessey Length Control 186 Plessey Set Length 1 187 Plessey Set Length 2 187 BC412 188 BC412 Enable Disable 188 ...

Страница 9: ...ility 217 CHAPTER 4 REFERENCES 219 RS 232 Parameters 220 RS 232 Only 220 Baud Rate 220 Data Bits 220 Stop Bits 220 Parity 220 Handshaking Control 220 RS 232 USB COM Parameters 221 Intercharacter Delay 221 ACK NAK Options 222 ACK Character 222 NAK Character 223 ACK NAK Timeout Value 224 ACK NAK Retry Count 225 Disable Character 226 Enable Character 227 Keyboard Interface 228 Wedge Quiet Interval 22...

Страница 10: ... GM4200 Gun Only 256 User Indications for WLC4190 Base Stations 258 Programming Mode 259 Troubleshooting 259 Standard Cable Pinouts 260 APPENDIX B STANDARD DEFAULTS 261 Default exceptions 270 APPENDIX C SAMPLE BARCODES 272 Sample Barcodes 272 1D Barcodes 272 GS1 Databar RSS 274 GS1 Databar 14 274 APPENDIX D KEYPAD 275 APPENDIX E SCANCODE TABLES 277 Control Character Emulation 277 Single Press and ...

Страница 11: ...uction provides a product overview unpacking instructions and cable connection information Chapter 2 Setup presents information about unpacking and setting up the scanner and interface configuration bar codes and details Chapter 3 Configuration Using Bar Codes provides instructions and bar code labels for customizing your scanner There are different sections for interface types general fea tures d...

Страница 12: ...ou of actions that could result in harm or injury to the person performing the task HIGH VOLTAGE This symbol alerts the user they are about to perform an action involving either a dangerous level of voltage or to warn against an action that could result in damage to devices or electrical shock LASER This symbol alerts the user they are about to perform an action involving possible exposure to lase...

Страница 13: ... the name of the product you re looking for This allows you access to download Data Sheets Manu als Software Utilities and Drawings Hover over the Support Service menu for access to Services and Technical Support Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A reseller is acquainted with specific types of businesses appl...

Страница 14: ...PREFACE xiv GRYPHON I GD GBT GM4200 NOTES ...

Страница 15: ...ses and manufacturing plants USING THE GRYPHON I GD GBT GM4200 READER To read a symbol or capture an image simply aim the reader and pull the trigger Data logic s exclusive patented Green Spot for good read feedback helps to improve produc tivity in noisy environments or in situations where silence is required When positioning the product into the stand the magnetic coupling will make the scanner ...

Страница 16: ...tery packs may get hot explode or ignite and cause serious injury if exposed to abusive conditions Be sure to follow the safety warn ings listed below Do not place the battery pack in fire or heat Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object such as wire Do not carry or store the battery pack together with metal objects Do not p...

Страница 17: ...plies battery pack chargers and docks supplied by your Datalogic reseller The use of any other power supplies can damage the device and void your warranty Do not disassemble or modify the battery The battery contains safety and protection devices which if damaged may cause the battery to generate heat explode or ignite Do not place the battery in or near fire on stoves or other high temperature lo...

Страница 18: ...ning the ENTER EXIT bar code a second time which will then accept your changes exit Programming Mode and return the reader to normal operation Datalogic Aladdin Datalogic Aladdin is a multi platform utility program providing a quick and user friendly configuration method via the RS 232 USB COM interface Aladdin allows you to program the reader by selecting configuration commands through a user fri...

Страница 19: ...T HOST INTERFACE The scanner kit you ordered to match your interface should provide a compatible cable for your installation If this is not so contact Technical Support on page xiii The scanner can communicate using the interfaces illustrated below For corded versions connect the reader cable by inserting the cable into the handle as shown in the following Figure To remove the interface cable from...

Страница 20: ...OPOS UPOS JavaPOS systems Keyboard Wedge Connection The Keyboard Wedge cable has a Y connection from the scanner Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal PC Keyboard Wedge KBW When connected using this interface the host interprets scanned data as keystrokes and supports several international keyboards for the Win dows environm...

Страница 21: ...ection to the Host NOTE Specific cables are required for connection to different hosts The connections illustrated in Figure 3 are examples only Actual connectors may vary from those illustrated but the steps to connect the scanner remain the same WEDGE RS 232 USB ...

Страница 22: ...egrated stand at a convenient angle allowing hands free scanning of items It can also be used as a holder The holder cup can be positioned in any of the angles shown in the figure below The Desk model automatically recognizes the insertion and changes its Scan Mode to allow the user to operate in hands free mode Figure 4 Adjusting the Stand Arm ...

Страница 23: ...modification of Regulation for shipping Li Ion based battery packs the products and their spare battery packs parts are shipped with a very low residual charge low state of charge Hence the needs that a new product must be fully recharged before starting to use it and that battery packs of the stocked products GBT GM42 and spare battery pack parts must be periodically recharged for instance by usi...

Страница 24: ...zontal or vertical position in order to provide the most comfortable use depending on the needs Base Station Positions and Related Clips to be Used Figure 5 Horizontal Position This position is preferred unless a different specific positioning is required for its utmost ease of insertion as well as the minimum effort and attention required by the customer when docking the scanner ...

Страница 25: ...CT REFERENCE GUIDE 11 Figure 6 Vertical Position This position is preferred when lack of room on the desktop recommends the scanner to be left vertical during recharging NOTE For vertical installation do not exceed two meters in height ...

Страница 26: ...o snap the adapter into the base Fix the base adapter unit to the wall panel using two screws Refer to Figure 10 for the positioning and the dimensions of the threaded brass screw holes Insert the two studs into the keyhole of the adapter Swipe down to block the studs into the narrowest part of the keyhole Refer to Figure 10 for the positioning and the dimensions of the keyhole mounting holes Figu...

Страница 27: ...SE STATION PRODUCT REFERENCE GUIDE 13 Figure 10 Mounting Holes Dimensions Figure 11 Overall Dimensions PP LQ PP LQ 17 5 5229 2 02817 1 2 9 57 02817 7 5 5 66 6 5 2 6 1R 0 2 02817 1 2 203 mm 8 in 84 mm 3 3 in 94 mm 3 7 in ...

Страница 28: ...gun provide information about the battery charging status as well as data transmission Figure 12 Gryphon 4200 Gun LEDs Figure 13 WLC4190 Base Station LEDs 1 Scan Window 3 Battery Recharge LED 2 Trigger 4 Good Read LED 1 Service Button 4 Cable Release Hole 2 Power LED 3 Recharge LED ...

Страница 29: ...nsert the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Station Then connect to an AC Adapter and plug the AC power cord into the wall outlet Figure 14 Connecting the Base Station NOTE The Gryphon GBT GM4200 can also be Powered by the Terminal When powered by the Terminal the battery charger is automatically set to Slow charge For some spec...

Страница 30: ...f the Base Station or fed directly out the back of the Base Station as shown in the figure below Figure 15 Options for routing the cable Host Connection Verify before connection that the reader s cable type is compatible with your host equipment Most connections plug directly into the host device as shown in Figure 16 Keyboard Wedge interface cables have a Y connection where its female end mates w...

Страница 31: ...he bottom side of the cradle Figure 17 Disconnecting the Cable from WLC4190 SYSTEM AND NETWORK LAYOUTS Stand Alone Layouts Figure 18 Single Reader Layout NOTE To detach the cable from the WLC4090 base station please refer to the procedure illustrated in Gryphon I 4500 Family Product Reference Guide available on www datalogic com HOST GRYPHON CRADLE ...

Страница 32: ... alone systems each cradle is connected to a single Host Figure 20 Multiple Stand Alone Layouts Many stand alone connections can operate in the same physical area without interfer ence provided all readers and cradles in the system have different addresses HOST CRADLE GRYPHON ...

Страница 33: ...DIO BASE Radio Base LEDs LEDs on the Gryphon Base provide information about the Base as well as battery charging status as shown in the figure below Figure 21 Gryphon Base LEDs Table 2 Radio Base LEDs Green On Base is powered Green Blinking Base receives data and commands from the Host or the Reader Green ON the battery is completely charged Green fading battery level 51 to 99 Amber fading battery...

Страница 34: ... the battery cable out of its connector and extract the battery pack from its slot NOTE Before proceeding read Battery Safety on page 2 To ensure max imum performance Datalogic recommends the replacement of the rechargeable battery pack if you note either of the following conditions battery life drops below approximately 80 of the original life battery charging time increases significantly ...

Страница 35: ...PHON I GD GBT GM4200 The Gryphon I GD4200 normally functions by capturing and decoding codes The aim ing system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code Aiming System Relative Size and Location of Aiming System Pattern NOTE When inserting the new battery into the handle take care to position the battery and the connecto...

Страница 36: ...necessary to link the handheld with the base To link the handheld and the base simply put it into the base If the reader was previ ously linked to another base you must first scan the Unlink bar code before re linking to the new base Unlink Link Scanner as Serial Device to a Bluetooth Host Use this procedure to let the scanner communicate with a Bluetooth host using the Bluetooth Serial Port Profi...

Страница 37: ...he scanner will appear in the program as if it was typed using the keyboard of the host device Link to Host in HID mode BLUETOOTH PASSKEY OR PIN CODE ENTRY REQUEST During the pairing process based on Host and Reader security settings you may need to enter a Bluetooth passkey or PIN code When requested by the Host simply enter the displayed code by scanning the corre sponding bar codes for alphanum...

Страница 38: ...d Wedge IBM46XX port 9b a specific cable is required Datalogic Magellan Scanners specific interface CONFIGURING THE INTERFACE Scan the programming bar code from the following section which selects the appropri ate interface type to match the system the scanner will be connected to Next proceed to the corresponding chapter in this manual also listed in the table to configure any desired settings an...

Страница 39: ...05 P Not supported on USB only models Select RS232 STD Select RS232 WN P HA12 P P HA13 P Select RS 232 OPOS USB COMA Select USB COM STD USB COM simulates RS 232 standard interface P HA47 P USB Composite combines USB KBD emulation and USB COM P HA4D P Select USB Composite a USB COM driver needs to be installed for these interfaces to work Please download it from www datalogic com ...

Страница 40: ... P Select Datalogic Magellan Scanners USB AUX Magellan RS232 AUX port Datalogic Magellan RS232 AUX port P HA43 P USB OEM Select USB OEM USB OEM can be used for OPOS UPOS JavaPOS P HA45 P NOTE If you erroneously read the USB OEM interface selection code it is required to press and hold the trigger to unlock the reader Then read the correct interface bar code This will work only at power up Please r...

Страница 41: ...ey encoding but without external keyboard P HA11 P AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key P HA26 P Select KBD AT ALT Select KBD AT ALT NK Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard P HA10 P USB Keyboard with standard key encoding P HA35 P Select USB Standard Keyboard Select USB Alternative Keyboard USB Keyboard with alternative key ...

Страница 42: ...tform utility program providing a quick and user friendly configuration method via the RS 232 USB COM interface The Aladdin utility is available on the Datalogic website Aladdin allows you to program the scanner by selecting configuration commands through a user friendly graphical interface running on a PC These commands are sent to the scanner over the selected communication interface or they can...

Страница 43: ...s Software Version Transmission The software version of the device can be transmitted over the RS 232 Keyboard and USB interfaces by scanning the following label Transmit Software Version Resetting the Product Configuration to Defaults Restore Custom Default Configuration If you aren t sure what programming options are in your scanner or you ve changed some options and want to restore the Custom D...

Страница 44: ...guration to the factory settings including the interface type The USA label restores Label IDs to those historically used in the USA The EU label restores Label IDs to those historically used in Europe The Label ID sets for USA and EU are shown in the Label ID Section on page 83 of this manual Restore USA Factory Configuration Restore EU Factory Configuration The programming items listed in the fo...

Страница 45: ... reference group Interface Configuration RS 232 Standard Settings starting on page 35 RS 232 USB COM Settings starting on page 40 Keyboard Interface starting on page 47 USB OEM Interface starting on page 76 Parameters common to all interface applications Global Prefix Suffix starting on page 81 Data Format starting on page 80 gives options to control the messages sent to the Host system by selecti...

Страница 46: ...nput parameters are needed go to Appendix D and scan the appro priate characters from the keypad 4 Complete the programming sequence by scanning the ENTER EXIT PROGRAM MING bar code to exit Programming Mode For more detailed descriptions programming information and examples for setting selected configuration items see References starting on page 219 NOTE You must first enable your reader to read b...

Страница 47: ...option specifies whether the reader will obey or ignore host commands When set to ignore the reader will ignore all host commands except those necessary for service mode flash programming mode keeping the interface active transmission of labels USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode CIFIH00 Host Commands Obey Do Not Ignore Host Commands H...

Страница 48: ...y to meet your system s requirements Additional settings which apply to both the RS 232 and USB interfaces are available in RS 232 USB COM Settings starting on page 40 Standard Factory Settings Reference Appendix B for a listing of standard factory settings SECTION CONTENTS RS 232 STANDARD SETTINGS starting on page 35 Baud Rate Data Bits Stop Bits Parity Handshaking Control ...

Страница 49: ...mitted per second Set the scanner s baud rate to match the baud rate setting of the host device With an improper baud rate set ting data may not reach the host correctly CR2BA00 Baud Rate 1200 Baud Rate 2400 CR2BA01 CR2BA02 Baud Rate 4800 Baud Rate 9600 CR2BA03 CR2BA04 Baud Rate 19 200 Baud Rate 38 400 CR2BA05 CR2BA06 Baud Rate 57 600 Baud Rate 115 200 CR2BA07 ...

Страница 50: ...ing device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match host device requirements CR2DA00 7 Data Bits 8 Data Bits CR2DA01 NOTE Handheld and Cradle models support the 8 bit ASCII protocol The 7 bit ASCII protocol support is subject to specific...

Страница 51: ...ity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0 or 1 based on data to ensure that an even number of 1 bits are contained in the coded character CR2PA00 ...

Страница 52: ...nored RTS CTS RTS is asserted during transmissions CTS gates transmissions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS gates transmissions RTS CTS Scan Control RTS is asserted during transmissions CTS gates transmis sions and controls enable and disable state of scanner CR2HC00 Handshaking Control RTS Handsh...

Страница 53: ...Appendix B for a listing of standard factory settings SECTION CONTENTS Intercharacter Delay Beep On ASCII BEL Beep On Not on File ACK NAK Options ACK Character NAK Character ACK NAK Timeout Value ACK NAK Retry Count ACK NAK Error Handling Indicate Transmission Failure Disable Character Enable Character ...

Страница 54: ...elay See Intercharacter Delay on page 221 for more detailed programming instructions CR2IC00 Intercharacter Delay No Delay Select Intercharacter Delay Setting CR2IC To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by dig its from the Alphanumeric characters in Appendix D representing your desired character s End by scan ning the ENTER EXIT bar code ag...

Страница 55: ... 232 serial line BEL is issued to gain a user s attention to an illegal entry or other important event Beep On Not on File This option enables disables the action of the scanner to sound a three beep sequence upon receiving a Not On File NOF host command Beep On ASCII BEL Disable CR2BB00 CR2BB01 Beep On ASCII BEL Enable Beep On Not On File Disable CBPNF00 CBPNF01 Beep On Not On File Enable ...

Страница 56: ...are Disable Enable for label transmission The scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The scanner will respond with ACK NAK when the host sends a command Enable for label transmission and host command acknowledge ACK NAK Protocol Disable ACK NAK CR2AE00 CR2AE01 ACK NAK Protocol Enable for label transmission ACK NAK Protocol Enable ...

Страница 57: ...d characters such as XON XOFF or host commands conflicts with normal operation of these characters 8 bit data is not recognized when the option Data Bits on page 36 has been set as 7 Data Bits Select ACK Character Setting CR2AC Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL 0x06 ACK Character NOTE Setting to previousl...

Страница 58: ...nt on page 225 for more detailed programming instructions Select ACK NAK Timeout Value Setting CR2AT To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by dig its from the Alphanumeric characters in Appendix D representing your desired character s End by scan ning the ENTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not sav...

Страница 59: ...ter Process error as valid NAK character Indicate Transmission Failure This option enables disables the scanner s ability to sound an error beep to indicate a transmission failure while in ACK NAK mode ACK NAK Error Handling Ignore Errors Detected CR2EH00 CR2EH01 ACK NAK Error Handling Process Error as Valid ACK Character ACK NAK Error Handling Process Error as Valid NAK Character CR2EH02 CR2TF00 ...

Страница 60: ...n page 227for more detailed programming instructions Setting to previously defined characters such as XON XOFF or host com mands conflicts with normal operation of these characters Select Disable Character Setting CR2DC Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL 0x44 Disable Character is D Setting to previously de...

Страница 61: ...Infor mation about control character emulation which applies to keyboard interfaces is listed in Appendix E Scancode Tables SECTION CONTENTS COUNTRY MODE starting on page 48 Setting Country Mode OTHER KEYBOARD PARAMETERS starting on page 63 Encoding Type ALT Output Type Caps Lock State Numlock Keyboard Numeric Keypad Keyboard Send Control Characters Wedge Quiet Interval Intercharacter Delay Interc...

Страница 62: ...ture specifies the country language supported by the keyboard The Country Mode setting is ignored if the interface uses alternate key encoding SETUP ON PC TO USE ALT UNIVERSAL 1 Open Registry Edit 2 Set EnableHexNumpad to 1 as follows 3 Reset the PC ...

Страница 63: ...T PROGRAMMING MODE PRODUCT REFERENCE GUIDE 49 Setting Country Mode United States CKBCO00 CKBCO01 French International Belgian French United Kingdom CKBCO02 CKBCO03 Danish French France CKBCO04 CKBCO05 German Italian CKBCO06 ...

Страница 64: ...G MODE KEYBOARD INTERFACE 50 GRYPHON I GD GBT GM4200 Setting Country Mode continued Norwegian CKBCO07 CKBCO08 Portuguese Portugal Spanish CKBCO09 CKBCO0A Swedish Swiss French CKBCO0B CKBCO0C Japanese ASCII Hungarian CKBCO0D ...

Страница 65: ...ENTER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 51 Setting Country Mode continued Czech CKBCO0E CKBCO0F SlovaK Romanian CKBCO10 CKBCO11 Croatian Polish_214 CKBCO12 CKBCO13 French Canadian Win7 Lithuanian CKBCO14 ...

Страница 66: ...MING MODE KEYBOARD INTERFACE 52 GRYPHON I GD GBT GM4200 Setting Country Mode continued Vietnamese CKBCO17 CKBCO18 Russian Arabic 101 CKBCO19 CKBCO1A Chinese ASCII Thai Kedmanee CKBCO1B CKBCO1C Albanian Arabic 102 CKBCO1D ...

Страница 67: ...AMMING MODE PRODUCT REFERENCE GUIDE 53 Setting Country Mode continued Arabic 102 AZERTY CKBCO1E CKBCO1F Azeri Cyrillic Azeri Latin CKBCO20 CKBCO21 Belarusian Bosnian Cyrillic CKBCO22 CKBCO23 Bosnian Latin Bulgarian Cyrillic CKBCO24 ...

Страница 68: ...E 54 GRYPHON I GD GBT GM4200 Setting Country Mode continued Bulgarian Latin CKBCO25 CKBCO26 Canadian French Legacy Canadian Multilingual CKBCO27 CKBCO28 Chinese Simplified Chinese Traditional CKBCO29 CKBCO2A Czech Programmers Czech QWERTY CKBCO2B ...

Страница 69: ... PROGRAMMING MODE PRODUCT REFERENCE GUIDE 55 Setting Country Mode continued Dutch Netherland CKBCO2C CKBCO2D Estonian Faeroese CKBCO2E CKBCO2F Finnish French Canada 2000 XP CKBCO30 CKBCO31 French Canada 95 98 Galician CKBCO32 ...

Страница 70: ...NG MODE KEYBOARD INTERFACE 56 GRYPHON I GD GBT GM4200 Setting Country Mode continued Greek CKBCO33 CKBCO34 Greek Latin Greek Polytonic CKBCO35 CKBCO36 Greek220 Greek220 Latin CKBCO37 CKBCO38 Greek319 Greek319 Latin CKBCO39 ...

Страница 71: ...EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 57 Setting Country Mode continued Hebrew Israel CKBCO3A CKBCO3B Hungarian_101KEY Icelandic CKBCO3C CKBCO3D Irish Italian_142 CKBCO3E CKBCO3F Japanese Shift JIS Kazakh CKBCO40 ...

Страница 72: ... KEYBOARD INTERFACE 58 GRYPHON I GD GBT GM4200 Setting Country Mode continued Korean Hangul CKBCO41 CKBCO42 Korean ASCII Kyrgyz Cyrillic CKBCO43 CKBCO44 Latin America Latvian CKBCO45 CKBCO46 Latvian QWERTY Lithuanian_IBM CKBCO47 ...

Страница 73: ...CT REFERENCE GUIDE 59 Setting Country Mode continued Macedonian FYROM CKBCO48 CKBCO49 Maltese_47KEY Mongolian Cyrillic CKBCO4A CKBCO4B Polish Programmer Portuguese Brazil CKBCO4C CKBCO4D Portuguese Brazilian ABNT Portuguese Brazilian ABNT2 CKBCO4E ...

Страница 74: ...NTERFACE 60 GRYPHON I GD GBT GM4200 Setting Country Mode continued Romanian Legacy CKBCO4F CKBCO50 Romanian Programmer Romanian Standard CKBCO51 CKBCO52 Russian Typewriter Serbian Cyrillic CKBCO53 CKBCO54 Serbian Latin Slovak QWERTY CKBCO55 ...

Страница 75: ...TER EXIT PROGRAMMING MODE PRODUCT REFERENCE GUIDE 61 Setting Country Mode continued Slovenian CKBCO56 CKBCO57 Spanish Variation Swiss German CKBCO58 CKBCO59 Tatar Turkish F CKBCO5A CKBCO5B Turkish Q Ukrainian CKBCO5C ...

Страница 76: ...RFACE 62 GRYPHON I GD GBT GM4200 Setting Country Mode continued US Dvorak CKBCO5D CKBCO5E US Dvorak Left Hand US Dvorak Right Hand CKBCO5F CKBCO60 US English Mac US English North American CKBCO61 CKBCO62 US International Uzbek Cyrillic CKBCO63 ...

Страница 77: ...3 OTHER KEYBOARD PARAMETERS Encoding Type Encoding Type Don t Use Encoding CENCO00 CENCO03 Encoding Type UTF_8 Encoding Type Windows 874 CENCO04 CENCO05 Encoding Type Windows 932 Encoding Type Windows 936 CENCO06 CENCO07 Encoding Type Windows 949 Encoding Type Windows 950 CENCO08 ...

Страница 78: ...200 Encoding Type continued Encoding Type Windows 1250 CENCO09 CENCO0A Encoding Type Windows 1251 Encoding Type Windows 1252 CENCO0B CENCO0C Encoding Type Windows 1253 Encoding Type Windows 1254 CENCO0D CENCO0E Encoding Type Windows 1255 Encoding Type Windows 1256 CENCO0F ...

Страница 79: ...GUIDE 65 Encoding Type continued Encoding Type Windows 1257 CENCO10 CENCO11 Encoding Type Windows 1258 Encoding Type Windows 20866 CENCO12 CENCO31 Encoding Type Windows 54936 Encoding Type ISO 8859 1 CENCO13 CENCO14 Encoding Type ISO 8859 2 Encoding Type ISO 8859 3 CENCO15 ...

Страница 80: ...BT GM4200 Encoding Type continued Encoding Type ISO 8859 4 CENCO16 CENCO17 Encoding Type ISO 8859 5 Encoding Type ISO 8859 6 CENCO18 CENCO19 Encoding Type ISO 8859 7 Encoding Type ISO 8859 8 CENCO1A CENCO1B Encoding Type ISO 8859 9 Encoding Type ISO 8859 10 CENCO1C ...

Страница 81: ...CE GUIDE 67 Encoding Type continued Encoding Type ISO 8859 11 CENCO1D CENCO1E Encoding Type ISO 8859 13 Encoding Type ISO 8859 14 CENCO1F CENCO20 Encoding Type ISO 8859 15 Encoding Type ISO 8859 16 CENCO21 CENCO22 Encoding Type MS DOS 437 Encoding Type MS DOS 737 CENCO23 ...

Страница 82: ...GBT GM4200 Encoding Type continued Encoding Type MS DOS 775 CENCO24 CENCO25 Encoding Type MS DOS 850 Encoding Type MS DOS 852 CENCO26 CENCO27 Encoding Type MS DOS 855 Encoding Type MS DOS 857 CENCO28 CENCO29 Encoding Type MS DOS 860 Encoding Type MS DOS 861 CENCO2A ...

Страница 83: ...DE PRODUCT REFERENCE GUIDE 69 Encoding Type continued Encoding Type MS DOS 862 CENCO2B CENCO2C Encoding Type MS DOS 863 Encoding Type MS DOS 865 CENCO2D CENCO2E Encoding Type MS DOS 866 Encoding Type MS DOS 869 CENCO2F CENCO30 Encoding Type Mac CP10000 ...

Страница 84: ...t the scanner may switch automatically between ALT mode Normal Keyboard Scancode to correctly display some characters that are not present in the current Keyboard Country ALT Output Type ALT Codepage use on non Unicode application Notepad COCPT00 COCPT01 ALT Output Type ALT Unicode use on Unicode application Word ALT Output Type ALT Universal Use for all COCPT02 COCPT03 ALT Output Type ALT Unicode...

Страница 85: ...encoding key board is selected This does not apply to USB Keyboard Numlock This option specifies the setting of the Numbers Lock Numlock key while in Keyboard Wedge interface This only applies to alternate key encoding interfaces It does not apply to USB Keyboard Caps Lock State Caps Lock OFF CKBCL00 CKBCL01 Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable CKBCL02 Numlock Numlock...

Страница 86: ...he format Ctrl Key Special keys are available in the range from 81H to A1 Send Ctrl Shift Key The behavior is the same as above but control keys are sent in the format Ctrl Shift Keys Send Special Function Key Send characters between 00H and 1FH according to the special function key mapping table see Interface Type PC AT PS 2 Alt Mode or USB Keyboard Alt Mode on page 280 This is used to send keys ...

Страница 87: ...e applies ONLY to the Keyboard Wedge interface Select Wegde Quiet Interval Setting CKBQI To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by dig its from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the ...

Страница 88: ...led programming instructions Set Intercode Delay CKBID To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the entry strin...

Страница 89: ...is option specifies the USB poll rate for a USB Keyboard NOTE This feature applies ONLY to the USB Keyboard interface USB Keyboard Speed 1ms CKBSP01 CKBSP02 USB Keyboard Speed 2ms USB Keyboard Speed 3ms CKBSP03 CKBSP05 USB Keyboard Speed 5ms USB Keyboard Speed 7ms CKBSP07 CKBSP0A USB Keyboard Speed 10ms ...

Страница 90: ...76 GRYPHON I GD GBT GM4200 CONFIGURATION USB OEM INTERFACE SECTION CONTENTS USB OEM Device Usage USB OEM Interface Options ...

Страница 91: ...ions are Tabletop Scanner Handheld Scanner USB OEM Interface Options This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands NOTE This feature is not compatible with Multiple Labels Reading in a Vol ume CIBUT00 USB OEM Device Usage Tabletop Scanner USB OEM Device Usage Handheld Sca...

Страница 92: ...78 GRYPHON I GD GBT GM4200 CONFIGURATION IBM 46XX INTERFACE SECTION CONTENTS IBM 46xx Interface Options ...

Страница 93: ...provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands CIFO101 Interface Options Obey Scanner Configuration Host Commands Interface Options Ignore Scanner Configuration Host Commands CIFO102 ...

Страница 94: ...ORMAT SECTION CONTENTS Global Prefix Suffix Global AIM ID GS1 128 AIM ID LABEL ID starting on page 83 Label ID Pre loaded Sets Label ID Set Individually Per Symbology Label ID Control Label ID Symbology Selection Case Conversion Character Conversion ...

Страница 95: ...e digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code again Set Global Prefix CLFPR Set Global Suffix CLFSU To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your des...

Страница 96: ...gramming instructions GS1 128 AIM ID If Global AIM ID is disabled the AIM ID for GS1 128 can be enabled disabled inde pendently The AIM ID for GS1 128 is a C1 C2 AIM IDs for other symbologies can be enabled disabled independently as well Contact Customer Support for assistance NOTE This feature enables disables addition of AIM IDs for all symbology types CAIEN00 Global AIM ID Disable Global AIM ID...

Страница 97: ...Per Symbology on page 84 If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 82 Label ID Pre loaded Sets The scanner supports two pre loaded sets of Label IDs the USA set and the EU set See Label ID Pre loaded Sets on page 234 for more information concerning the pre loaded sets that are pr...

Страница 98: ...n controls whether a Label ID is disabled or sent as a prefix or suffix for a given symbology type NOTE This setting requires the scanning of bar codes from multiple sec tions See Label ID Set Individually Per Symbology on page 236 for more detailed programming instructions CIDCO00 Label ID Transmission Disable Label ID Transmission Enable as Prefix CIDCO01 CIDCO02 Label ID Transmission Enable as ...

Страница 99: ...6 for full instructions Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL CABID Set UPC A Label ID Character s Set UPC A P2 Label ID Character s CA2ID CA5ID Set UPC A P5 Label ID Character s Set UPC E Label ID Character s CEBID CE2ID Set UPC E P2 Label ID Character s Set UPC E P5 Label ID Character s CE5ID C3BID Set EAN ...

Страница 100: ...AN 13 P2 Label ID Character s Set EAN 13 P5 Label ID Character s C35ID CISID Set ISBN Label ID Character s Set ISSN Label ID Character s CINID C8BID Set EAN 8 Label ID Character s Set EAN 8 P2 Label ID Character s C82ID C85ID Set EAN 8 P5 Label ID Character s Set GS1 DataBar Omnidirectional Label ID Character s C4BID ...

Страница 101: ...nded Label ID Character s Set GS1 DataBar Limited Label ID Character s CLBID CC3ID Set Code 39 Label ID Character s Set Code 32 Label ID Character s CP3ID CCCID Set Code 39 CIP Label ID Character s Set Code 128 Label ID Character s CC8ID CU8ID Set Code GS1 128 Label ID Character s Set Interleaved 2 of 5 Label ID Character s CI2ID ...

Страница 102: ... of 5 CIP HR Label ID Character s Datalogic 2 of 5 Label ID Character s CD2ID CS2D Standard 2 of 5 Label ID Character s Industrial 2 of 5 Label ID Character s CU2ID CIAID IATA Label ID Character s Codabar Label ID Character s CCBID CACID ABC Codabar Label ID Character s ISBT 128 Label ID Character s single and concatenated CI8ID ...

Страница 103: ...ROGRAMMING MODE PRODUCT REFERENCE GUIDE 89 Label ID Symbology Selection continued CC1ID Code 11 Label ID Character s MSI Label ID Character s CMSID CPLID Plessey Label ID Character s Anker Plessey Label ID Character s CALID ...

Страница 104: ...or more detailed programming instructions NOTE Case conversion affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data CLFCA00 Case Conversion Disable no case conversion Case Conversion Convert to upper case CLFCA01 CLFCA02 Case Conversion Convert to lower case Configure Character Conversion CLFCH To configure this feature scan the ENTER EXIT PRO GRAMMI...

Страница 105: ...ash Stand Mode Object Detection Sensitivity Stand Mode Object Detection Illumination Off Time Corded Stand Mode BEEPER CONTROL starting on page 99 Power On Alert Good Read Beep Type Good Read Beep Frequency Good Read Beep Length Good Read Beep Volume LED CONTROL starting on page 103 RGB Good Read Enable RGB Good Read Color Good Read LED Duration Good Read When to Indicate Green Spot Duration Illum...

Страница 106: ...eader s scan operating mode See page 239 in References for descriptions 3 Scan Mode Trigger Single CSNRM00 CSNRM01 Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple CSNRM02 CSNRM03 Scan Mode Flashing Scan Mode Always On CSNRM04 CSNRM05 Scan Mode Object Detection Scan Mode Trigger Object Sense CSNRM06 ...

Страница 107: ...9 9 seconds in 100 millisecond incre ments See page 242 in References for detailed information on setting this feature CSNET03 Scanning Active Time 3 seconds Scanning Active Time 5 seconds CSNET05 CSNET08 Scanning Active Time 8 seconds Select Flash ON Time Setting CSNFN To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits f...

Страница 108: ...ain within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label read Select Flash OFF Time Setting CSNFF To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desir...

Страница 109: ...IDE 95 Double Read Timeout continued CSNDR32 Double Read Timeout 0 5 Second Double Read Timeout 0 6 Second CSNDR3C CSNDR46 Double Read Timeout 0 7 Second Double Read Timeout 0 8 Second CSNDR50 CSNDR5A Double Read Timeout 0 9 Second Double Read Timeout 1 Second CSNDR64 ...

Страница 110: ...mode switching when the reader is placed in a stand Switch to Stand Mode Object Detection Automatically switches the reader to Stand Mode Object Detection when the reader is placed in the stand Switch to Always On Automatically switches the reader to Always On mode when the reader is placed in the stand Switch to Flashing Automatically switches the reader to Flash Mode when the reader is placed in...

Страница 111: ... will blink when Stand Mode scanning is active Stand Mode Object Detection Sensitivity Sets the sensitivity level for stand mode object detection wakeup Choices are low medium and high CSMFL00 Stand Mode Object Detection Indication Disable Stand Mode Object Detection Indication Enable CSMFL01 CSMSE00 Stand Base Detection Sensitivity Low Stand Base Detection Sensitivity Medium CSMSE01 CSMSE02 Stand...

Страница 112: ...dels only Set Illumination OFF Time CSNTM To configure scan the ENTER EXIT PROGRAMMING MODE bar code above then the bar code at left fol lowed by the digits from the Alphanumeric charac ters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the...

Страница 113: ...les the indication from the Beeper that the reader is receiving power Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound CBPPU00 Power On Alert Disable No Audible Indication Power On Alert Power up Beep CBPPU01 CBPTY00 Good Read Beep Type Mono Good Read Beep Type Bitonal CBPTY01 ...

Страница 114: ... Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below Controls the beeper s pitch tone CBPFR00 Good Read Beep Frequency Low Good Read Beep Frequency Medium CBPFR01 CBPFR02 Good Read Beep Frequency High ...

Страница 115: ... Good Read Beep Length 60 msec Good Read Beep Length 80 msec CBPLE08 CBPLE0A Good Read Beep Length 100 msec Good Read Beep Length 120 msec CBPLE0C CBPLE0E Good Read Beep Length 140 msec Good Read Beep Length 160 msec CBPLE10 CBPLE12 Good Read Beep Length 180 msec Good Read Beep Length 200 msec CBPLE14 ...

Страница 116: ...4200 Good Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three select able volume levels CBPVO00 Good Read Beep Volume Beeper Off Good Read Beep Volume Low CBPVO01 CBPVO02 Good Read Beep Volume Medium Good Read Beep Volume High CBPVO03 ...

Страница 117: ...Read Enable Specifies whether the RGB good read indicator is enabled or disabled RGB Good Read Color Selects the good read LED color CRBGE00 RGB Good Read Disable RGB Good Read Enable CRBGE01 CRBCL00 RGB Good Read Color RED RGB Good Read Color GREEN CRBCL01 CRBCL02 RGB Good Read Color BLUE ...

Страница 118: ...uctions and examples for setting this fea ture CLAGL00 Good Read LED Duration Setting Keep LED on until next trigger pull Select Good Read LED Duration Setting CLAGL To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scann...

Страница 119: ... Indicate This feature specifies when the reader will provide indication beep and or flash its green LED upon successfully reading a bar code CBPIN00 Indicate Good Read After Decode Indicate Good Read After Transmit CBPIN01 CBPIN02 Indicate Good Read After CTS goes inactive then active ...

Страница 120: ...r Intensity Power Level This setting selects the illumination level for bar code reading CLSSP00 Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec CLSSP01 CLSSP02 Green Spot Duration Medium 500 msec Green Spot Duration Long 800 msec CLSSP03 CIPWL01 Illuminator Intensity Low Illuminator Intensity Medium CIPWL06 CIPWL0C Illuminator Intensity High ...

Страница 121: ... PROGRAMMING MODE PRODUCT REFERENCE GUIDE 107 CAMERA CONTROL Aiming Pointer Enables disables the aiming pointer for all symbologies CTAAP00 Aiming Pointer Disable Aiming Pointer Enable CTAAP01 CTAAP02 Aiming Pointer Green Spot ...

Страница 122: ...108 GRYPHON I GD GBT GM4200 CONFIGURATION MOTION FEATURES SECTION CONTENTS MOTION FEATURES starting on page 109 Motionless Timeout Motion Sensitivity High Motion Immunity Motion Aiming Control ...

Страница 123: ...Sets the sensitivity level for motion detection wakeup Choices are low medium and high Select Motionless Timeout CMOTO To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT bar code again Make a mistak...

Страница 124: ... for rapidly moving barcodes Enable High Motion Immunity increased performance for distant barcodes Disable High Motion Immunity Depending on specific environmental conditions application requirements or expected performance choose the best solution Motion Aiming Control Enables Disables the Aiming system when motion is detected CMOSI00 High Motion Immunity Disable High Motion Immunity Enable CMOS...

Страница 125: ...IDIRECTIONAL starting on page 127 INDUSTRIAL 2 OF 5 starting on page 159 GS1 DATABAR EXPANDED starting on page 128 IATA starting on page 162 GS1 DATABAR LIMITED starting on page 131 FOLLETT 2 OF 5 starting on page 163 CODE 39 starting on page 132 CODABAR starting on page 164 TRIOPTIC CODE starting on page 137 ABC CODABAR starting on page 170 CODE 39 DANISH PPT starting on page 137 ISBT 128 startin...

Страница 126: ...GS1 DataBar enables only GS1 DataBar coupon decoding To set this feature 1 Scan the Enter Exit bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing page to ensure that the scanner sees only the bar code you intend to scan 3 Complete the programming sequence by scanning the Enter Exit bar code AD Disable All Symbologies CCPCL00...

Страница 127: ...ble Disable When disabled the scanner will not read UPC A bar codes UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A bar code data CABEN00 UPC A Disable UPC A Enable CABEN01 CABCT00 UPC A Check Character Transmission Don t Send UPC A Check Character Transmission Send CABCT01 ...

Страница 128: ...e also changes the symbology ID to match those required for EAN 13 UPC A Number System Character Transmission This feature enables disables transmission of the UPC A number system character CAB3B00 UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand CAB3B01 CABNS00 UPC A Number System Character Do not transmit UPC A Number System Character Transmit CABNS01 ...

Страница 129: ...ble Disable When disabled the scanner will not read UPC E bar codes UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E bar code data CEBEN00 UPC E Disable UPC E Enable CEBEN01 CEBCT00 UPC E Check Character Transmission Don t Send UPC E Check Character Transmission Send CEBCT01 ...

Страница 130: ...o the UPC A data format Selecting this feature also changes the symbology ID to match those required for UPC A UPC E Number System Character Transmission This feature enables disables transmission of the UPC E number system character CEB3B00 UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand CEB3B01 CEBAB00 UPC E to UPC A Don t Expand UPC E to UPC A Expand CEBAB01 CEBNS00 UPC E Number System Char...

Страница 131: ...DE PRODUCT REFERENCE GUIDE 117 GTIN Formatting This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format CGBEN00 GTIN Formatting Disable GTIN Formatting Enable CGBEN01 ...

Страница 132: ...able Disable When disabled the scanner will not read EAN 13 bar codes EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 bar code data C3BEN00 EAN 13 Disable EAN 13 Enable C3BEN01 C3BCT00 EAN 13 Check Character Transmission Don t Send EAN 13 Check Character Transmission Send C3BCT01 ...

Страница 133: ...ter The Flag 1 character is the first character of the label EAN 13 to ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookland labels starting with 978 to ISBN labels C3BF100 EAN 13 Flag 1 Char Don t transmit EAN 13 Flag 1 Char Transmit C3BF101 C3BIS00 EAN 13 ISBN Conversion Disable EAN 13 ISBN Conversion Enable C3BIS01 ...

Страница 134: ...ROGRAMMING MODE SYMBOLOGIES 120 GRYPHON I GD GBT GM4200 EAN 13 to ISSN Conversion Enables disables conversion of EAN JAN 13 Bookland labels starting with 977 to ISSN labels C3BIN00 ISSN Disable ISSN Enable C3BIN01 ...

Страница 135: ...ble Disable When disabled the scanner will not read EAN 8 bar codes EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar code data C8BEN00 EAN 8 Disable EAN 8 Enable C8BEN01 C8BCT00 EAN 8 Check Character Transmission Don t Send EAN 8 Check Character Transmission Send C8BCT01 ...

Страница 136: ...PROGRAMMING MODE SYMBOLOGIES 122 GRYPHON I GD GBT GM4200 Expand EAN 8 to EAN 13 Enable this option to expand EAN 8 JAN 8 labels to EAN 13 JAN 13 C8B3B00 EAN 8 to EAN 13 Don t Expand EAN 8 to EAN 13 Expand C8B3B01 ...

Страница 137: ...ication of price weight check digits Options are Disabled Enable 4 digit price weight check digit calculation Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation CPWEN00 Price Weight Check Disabled Price Weight Check 4 digit price weight check CPWEN01 CPWEN02 Price Weight Check...

Страница 138: ...ds of a bar code typically 10 times the width of the narrowest bar or space in the label The property applies to all EAN UPC symbologies globally and to the ADD ONs Add Ons The following features apply to optional add ons CUNLO02 UPC EAN Quiet Zones Two Modules UPC EAN Quiet Zones Three Modules CUNLO03 NOTE Contact Customer Support for advanced programming of optional and conditional add ons ...

Страница 139: ...add on are both decoded the scan ner will transmit the base label and add on If a UPC EAN base label is decoded without an add on the base label will be transmitted without an add on Conditional add on settings if enabled are considered by the scanner before optional add on settings CADO200 Optional Add Ons Disable P2 Optional Add Ons Enable P2 CADO201 CADO500 Optional Add Ons Disable P5 Optional ...

Страница 140: ...ook for an add on when an add on fragment has been seen and optional add ons are enabled CADOT01 Optional Add on Timer 10ms Optional Add on Timer 20ms CADOT02 CADOT03 Optional Add on Timer 30ms Optional Add on Timer 50ms CADOT05 CADOT07 Optional Add on Timer 70ms Optional Add on Timer 100ms CADOT0A CADOT10 Optional Add on Timer 160ms ...

Страница 141: ... When disabled the scanner will not read GS1 DataBar Omnidirectional bar codes GS1 DataBar Omnidirectional to GS1 128 Emulation When enabled GS1 DataBar Omnidirectional bar codes will be translated to the GS1 128 label data format C4BEN00 GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable C4BEN01 C4BU800 GS1 DataBar Omnidirectional to GS1 128 Emulation Disable GS1 DataBar Omnid...

Страница 142: ...e Disable When disabled the scanner will not read GS1 DataBar Expanded bar codes GS1 DataBar Expanded to GS1 128 Emulation When enabled GS1 DataBar Expanded bar codes will be translated to the GS1 128 label data format CXBEN00 GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable CXBEN01 CXBU800 GS1 DataBar Expanded to GS1 128 Emulation Disable GS1 DataBar Expanded to GS1 128 Emulation Enable C...

Страница 143: ...d length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 74 characters See Set Length 1 on page 247 for more detailed programming instructions CXBLC00 GS1 DataBar Expanded Length Control Variable Length GS1 DataBar Expanded Length Control Fixed Length CXBLC01 Select GS1 DataBar Expanded Set Length 1 Setting CXBL1 To configure this feature...

Страница 144: ...A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select GS1 DataBar Expanded Set Length 2 Setting CXBL2 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your ...

Страница 145: ...Enable Disable When disabled the scanner will not read GS1 DataBar Limited bar codes GS1 DataBar Limited to GS1 128 Emulation When enabled GS1 DataBar Limited bar codes will be translated to the GS1 128 label data format CLBEN00 GS1 DataBar Limited Disable GS1 DataBar Limited Enable CLBEN01 CLBU800 GS1 DataBar Limited to GS1 128 Emulation Disable GS1 DataBar Limited to GS1 128 Emulation Enable CLB...

Страница 146: ... enable disable calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data character CC3EN00 Code 39 Disable Code 39 Enable CC3EN01 CC3CC00 Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std Check CC3CC01 CC3CC02 Code 39 Check Character Calculation Calculate Mod 7 Check C...

Страница 147: ...acter Transmission Enable this option to enable disable transmission of Code 39 start and stop characters CC3CC08 Code 39 Check Character Calculation Enable Daimler Chrysler Check CC3CT00 Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send CC3CT01 CC3SS00 Code 39 Start Stop Character Transmission Don t Transmit Code 39 Start Stop Character Transmission Transmi...

Страница 148: ...Code 39 labels Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrow est bar or space in the label CC3FA00 Code 39 Full ASCII Disable Code 39 Full ASCII Enable CC3FA01 CC3LO01 Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zones Quiet Zones on two sides CC3LO02 CC3LO03 Code 39 Quiet Zones Auto Code 39 Quiet Zones Virtual Quiet Zones on t...

Страница 149: ... the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 0 to 50 characters See Set Length 1 on page 247 for more detailed programming instructions CC3LC00 Code 39 Length Control Variable Length Code 39 Length Control Fixed Length CC3LC01 Select Code 39 Set Length 1 Setting CC3L1 To configure this feature scan the ENTER...

Страница 150: ...e set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Code 39 Set Length 2 Setting CC3L2 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad re...

Страница 151: ... disabled the scanner will not read Trioptic Code bar codes CODE 39 DANISH PPT The following options apply to the Code 39 Danish PPT symbology Code 39 Danish PPT Enable Disable When disabled the scanner will not read Code 39 Danish PPT bar codes CCTEN00 Trioptic Code Disable Trioptic Code Enable CCTEN01 CDPEN00 Code 39 Danish PPT Disable Code 39 Danish PPT Enable CDPEN01 ...

Страница 152: ...le When disabled the scanner will not read Code 39 PZN bar codes CODE 39 LA POSTE The following options apply to the Code 39 La Poste symbology Code 39 La Poste Enable Disable When disabled the scanner will not read Code 39 La Poste bar codes CPZEN00 Code 39 PZN Disable Code 39 PZN Enable CPZEN01 CLPEN00 Code 39 La Poste Disable Code 39 La Poste Enable CLPEN01 ...

Страница 153: ...ode 32 Feature Setting Exceptions Code 32 Check Character Transmission Enable this option to transmit the check character along with Code 32 bar code data CP3EN00 Code 32 Disable Code 32 Enable CP3EN01 NOTE The following features are set for Code 32 by using these Code 39 settings Code 39 Quiet Zones on page 134 Code 39 Length Control on page 135 CP3CT00 Code 32 Check Character Transmission Don t ...

Страница 154: ... stop characters CODE 39 CIP FRENCH PHARMACEUTICAL The following options apply to the Code 39 CIP symbology Code 39 CIP Enable Disable Enables Disables ability of the scanner to decode Code 39 CIP labels CP3SS00 Code 32 Start Stop Character Transmission Don t Transmit Code 32 Start Stop Character Transmission Transmit CP3SS01 CCCEN00 Code 39 CIP Disable Code 39 CIP Enable CCCEN01 ...

Страница 155: ... decode Code 128 labels Expand Code 128 to Code 39 This feature enables disables expansion of Code 128 labels to Code 39 labels When enabled the label identifier for a Code 128 label shall be set to Code 39 and all Code 39 formatting control shall be applied to the label CC8EN00 Code 128 Disable Code 128 Enable CC8EN01 CC8C300 Code 128 to Code 39 Don t Expand Code 128 to Code 39 Expand CC8C301 ...

Страница 156: ... with Code 128 bar code data Code 128 Function Character Transmission Enables disables transmission of Code128 function characters 1 2 3 and 4 CC8CT00 Code 128 Check Character Transmission Don t Send Code 128 Check Character Transmission Send CC8CT01 CC8TF00 Code 128 Function Character Transmission Don t Send Code 128 Function Character Transmission Send CC8TF01 ...

Страница 157: ...e length decoding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CC8LO00 Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zones Quiet Zone on one side CC8LO01 CC8LO02 Code 128 Quiet Zones Quiet Zones on two sides Code 128 Quiet Zones Auto CC8LO03 C...

Страница 158: ... length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Code 128 Set Length 1 Setting CC8L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT b...

Страница 159: ...mit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels INTERLEAVED 2 OF 5 I 2 OF 5 The following options apply to the I 2 of 5 symbology CU8EN00 GS1 128 Transmit in Code 128 data format GS1 128 Transmit in GS1 128 data format CU8EN01 CU8EN02 GS1 128 Do not transmit GS1 128 labels CAUTION When reading this symbology the settings for ...

Страница 160: ...ion of an optional I 2 of 5 check character CI2EN00 I 2 of 5 Disable I 2 of 5 Enable CI2EN01 CI2CC00 I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Calculate Std Check Modulo 10 no AR CI2CC01 CI2CC02 I 2 of 5 Check Character Calculation Calculate German Parcel Check I 2 of 5 Check Character Calculation Calculate DHL Check CI2CC04 CI2CC08 I 2 of 5 Check Character ...

Страница 161: ...ansmit the check character along with I 2 of 5 bar code data I 2 of 5 Check Character Calculation Calculate Bosch Check CI2CC10 CI2CC20 I 2 of 5 Check Character Calculation Calculate Italian Post Check NOTE This feature is valid only when I 2 of 5 Check Character Calculation is enabled CI2CT00 I 2 of 5 Check Character Transmission Don t Send I 2 of 5 Check Character Transmission Send CI2CT01 ...

Страница 162: ...th Mode The length includes the bar code s check and data char acters The length can be set from 2 to 50 characters in increments of two See Set Length 1 on page 247 for more detailed programming instructions CI2LC00 I 2 of 5 Length Control Variable Length I 2 of 5 Length Control Fixed Length CI2LC01 Select I 2 of 5 Set Length 1 Setting CI2L1 To configure this feature scan the ENTER EXIT PRO GRAMM...

Страница 163: ...ctions INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology Interleaved 2 of 5 CIP HR Enable Disable Enables Disables ability of the scanner to decode Interleaved 2 of 5 CIP HR labels Select I 2 of 5 Set Length 2 Setting CI2L2 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits f...

Страница 164: ...bled the scanner will not read Standard 2 of 5 bar codes Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Standard 2 of 5 check character CS2EN00 Standard 2 of 5 Disable Standard 2 of 5 Enable CS2EN01 CS2CC00 Standard 2 of 5 Check Character Calculation Disable Standard 2 of 5 Check Character Calculation Enable CS2CC01 ...

Страница 165: ...either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CS2CT00 Standard 2 of 5 Check Character Transmission Don t Send Standard 2 of 5 Check Character Transmission Send CS2CT01 CS2LC00 Standard 2 of 5 Length Control Var...

Страница 166: ...fies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Standard 2 of 5 Length 1 Setting CS2L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by sca...

Страница 167: ...led the scanner will not read Compressed 2 of 5 bar codes Compressed 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Compressed 2 of 5 check character CC2EN00 Compressed 2 of 5 Disable Compressed 2 of 5 Enable CC2EN01 CC2CC00 Compressed 2 of 5 Check Character Calculation Disable Compressed 2 of 5 Check Character Calculation Enable CC2CC01...

Страница 168: ...er variable length decoding or fixed length decoding for the Compressed 2 of 5 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CC2CT00 Compressed 2 of 5 Check Character Transmission Don t Send Compressed 2 of 5 Check Character Transmission Send CC2CT01 CC2LC00 Compressed 2 of 5 Length Control...

Страница 169: ...pecifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Compressed 2 of 5 Length 1 Setting CC2L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End ...

Страница 170: ...ed the scanner will not read Datalogic 2 of 5 bar codes Datalogic 2 of 5 Check Character Calculation This option enables disables calculation and verification of an optional Datalogic 2 of 5 check character CD2EN00 Datalogic 2 of 5 Disable Datalogic 2 of 5 Enable CD2EN01 CD2CC00 Datalogic 2 of 5 Check Character Calculation Disable Datalogic 2 of 5 Check Character Calculation Enable CD2CC01 ...

Страница 171: ...either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CD2CT00 Datalogic 2 of 5 Check Character Transmission Don t Send Datalogic 2 of 5 Check Character Transmission Send CD2CT01 CD2LC00 Datalogic 2 of 5 Length Control...

Страница 172: ... of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed programming instructions Select Datalogic 2 of 5 Length 1 Setting CD2L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character ...

Страница 173: ...disabled the scanner will not read Industrial 2 of 5 bar codes Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of an optional Industrial 2 of 5 check char acter CU2EN00 Industrial 2 of 5 Disable Industrial 2 of 5 Enable CU2EN01 CU2CC00 Industrial 2 of 5 Check Character Calculation Disable Industrial 2 of 5 Check Character Calculation Enable CU2CC01 ...

Страница 174: ...length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CU2CT00 Industrial 2 of 5 Check Character Transmission Don t Send Industrial 2 of 5 Check Character Transmission Send CU2CT01 CU2LC00 Industrial 2 of 5 Length Control Variable Le...

Страница 175: ...specifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Industrial 2 of 5 Length 1 Setting CU2L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End...

Страница 176: ...le Disable Enables Disables the ability of the scanner to decode IATA labels IATA Check Character Transmission Enables Disables calculation and verification of an optional IATA check character CIAEN00 IATA Disable IATA Enable CIAEN01 CIACT00 IATA Check Character Transmission Don t Send IATA Check Character Transmission Send CIACT01 ...

Страница 177: ...REFERENCE GUIDE 163 FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disable Enables Disables ability of scanner to decode Follett 2 of 5 labels CF2EN00 Follett 2 of 5 Disable Follett 2 of 5 Enable CF2EN01 ...

Страница 178: ... enables disables calculation and verification of an optional Codabar check character When disabled any check characters in the label are treated as data charac ters CCBEN00 Codabar Disable Codabar Enable CCBEN01 CCBCC00 Codabar Check Character Calculation Disable Codabar Check Character Calculation Calculate AIM Std Check CCBCC01 CCBCC02 Codabar Check Character Calculation Calculate Modulo 10 Che...

Страница 179: ...cter Transmission This option enables disables transmission of Codabar start and stop characters NOTE This feature is valid only when Codabar Check Character Calculation is enabled CCBCT00 Codabar Check Character Transmission Don t Send Codabar Check Character Transmission Send CCBCT01 CCBSS00 Codabar Start Stop Character Transmission Don t Transmit Codabar Start Stop Character Transmission Transm...

Страница 180: ...Stop Character Match When enabled this option requires that start and stop characters match CCBSC00 Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD CCBSC01 CCBSC02 Codabar Check Character Set abcd tn e Codabar Check Character Set abcd abcd CCBSC03 CCBSM00 Codabar Start Stop Character Match Don t Require Match Codabar Start Stop Character Match Require Match CCBSM01 ...

Страница 181: ...nk areas at the ends of a bar code and are typically 10 times the width of the narrow est bar or space in the label CCBLO01 Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zones Quiet Zones on two sides CCBLO02 CCBLO03 Codabar Quiet Zones Auto Codabar Quiet Zones Virtual Quiet Zones on two sides CCBLO04 CCBLO05 Codabar Quiet Zones Small Quiet Zones on two sides ...

Страница 182: ...cludes the bar code s start stop check and data characters The length must include at least one data character The length can be set from 3 to 50 characters See Set Length 1 on page 247 for more detailed programming instructions CCBLC00 Codabar Length Control Variable Length Codabar Length Control Fixed Length CCBLC01 Select Codabar Length 1 Setting CCBL1 To configure this feature scan the ENTER E...

Страница 183: ...e set from 3 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Codabar Length 2 Setting CCBL2 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad repres...

Страница 184: ...ogy ABC Codabar Enable Disable Enables Disables ability of scanner to decode ABC Codabar labels ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic CCBAB00 ABC Codabar Disable ABC Codabar Enable CCBAB01 CCBCM00 ABC Codabar Contatenation Mode Static ABC Codabar Concatenation Mode Dynamic CCBCM01 ...

Страница 185: ...atenated labels are transmitted while Codabar stand alone labels are not transmitted Force Concatenation has no effect if the ABC Codabar Concatenation is disabled The Force Concatenation mode has effect both in Static and Dynamic Concatenation Modes Select ABC Codabar Dynamic Concatenation Timeout Setting CCBDT To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then th...

Страница 186: ...gy ISBT 128 Concatenation Enables disables ISBT 128 concatenation of 2 labels ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic CI8CE00 ISBT 128 Concatenation Disable ISBT 128 Concatenation Enable CI8CE01 CI8CM00 ISBT 128 Contatenation Mode Static ISBT 128 Concatenation Mode Dynamic CI8CM01 ...

Страница 187: ...c Concatenation Mode CI8DT05 ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec CI8DT0A CI8DT14 ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatenation Timeout 500 msec CI8DT32 CI8DT4B ISBT 128 Dynamic Concatenation Timeout 750 msec ISBT 128 Dynamic Concatenation Timeout 1 second CI8DT64 ...

Страница 188: ...concatenated ISBT 128 Advanced Concatenation Options NOTE This option is only valid when ISBT 128 Concatenation on page 172 is enabled CI8FC00 ISBT 128 Force Contatenation Disable ISBT 128 Force Concatenation Enable CI8FC01 NOTE Use the Datalogic Aladdin configuration application or Contact Cus tomer Support to set up pairs of label types for concatenation ...

Страница 189: ...1 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character CC1EN00 Code 11 Disable Code 11 Enable CC1EN01 CC1CC00 Code 11 Check Character Calculation Disable Code 11 Check Character Calculation Calculate Check C CC1CC01 CC1CC02 Code 11 Check Character Calculation Calculate Check K Code 11 Check Character Calculation Calculate Check C...

Страница 190: ...fies either variable length decoding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CC1CT00 Code 11 Check Character Transmission Don t Send Code 11 Check Character Transmission Send CC1CT01 CC1LC00 Code 11 Length Control Variable Length Code 11 Length...

Страница 191: ...re this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Code 11 Length 1 Setting CC1L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT...

Страница 192: ...e 93 Check Character Calculation This option enables disables calculation and verification of optional Code 93 check character CC9EN00 Code 93 Disable Code 93 Enable CC9EN01 CC9CC00 Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Calculate Check C CC9CC01 CC9CC02 Code 93 Check Character Calculation Calculate Check K Code 93 Check Character Calculation Calculate Chec...

Страница 193: ...es either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CC9CT00 Code 93 Check Character Transmission Don t Send Code 93 Check Character Transmission Send CC9CT01 CC9LC00 Code 93 Length Control Variable Length Code 93 Length C...

Страница 194: ...ignore this length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select Code 93 Length 1 Setting CC9L1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER ...

Страница 195: ... are blank areas at the ends of a bar code and are typically 10 times the width of the narrow est bar or space in the label CC9LO00 Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side CC9LO01 CC9LO02 Code 93 Quiet Zones Quiet Zones on two sides Code 93 Quiet Zones Auto CC9LO03 CC9LO04 Code 93 Quiet Zones Virtual Quiet Zones on two sides ...

Страница 196: ...MSI labels MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check character CMSEN00 MSI Disable MSI Enable CMSEN01 CMSCC00 MSI Check Character Calculation Disable MSI Check Character Calculation Calculate Mod 10 CMSCC01 CMSCC02 MSI Check Character Calculation Calculate Mod 11 10 MSI Check Character Calculation Calculate Mod 10 10 CMSCC03 ...

Страница 197: ... variable length decoding or fixed length decoding for the MSI symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CMSCT00 MSI Check Character Transmission Don t Send MSI Check Character Transmission Send CMSCT01 CMSLC00 MSI Length Control Variable Length MSI Length Control Fixed Length CMSLC01 ...

Страница 198: ...s length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select MSI Length 1 Setting CMSL1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT bar code ...

Страница 199: ...er Calculation Enables Disables calculation and verification of a Plessey check character CPLEN00 Plessey Disable Plessey Enable CPLEN01 CPLCC00 Plessey Check Character Calculation Disable Plessey Check Character Calculation Plessey std check char verification CPLCC01 CPLCC02 Plessey Check Character Calculation Anker check char verification Plessey Check Character Calculation Plessey std and Anker...

Страница 200: ... variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CPLCT00 Plessey Check Character Transmission Don t Send Plessey Check Character Transmission Send CPLCT01 CPLLC00 Plessey Length Control Variable Length Plessey Length Control Fi...

Страница 201: ...nore this length only one fixed length See Set Length 2 on page 248 for more detailed programming instructions Select Plessey Length 1 Setting CPLL1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXI...

Страница 202: ... to decode BC412 labels BC412 Check Character Calculation Enable this option to enable disable calculation and verification of an optional BC412 check character When disabled any check character in the label is treated as a data character CBCEN00 BC412 Disable BC412 Enable CBCEN01 CBCCC00 BC412 Check Character Calculation Disable BC412 Check Character Calculation Calculate CBCCC01 ...

Страница 203: ...ther variable length decoding or fixed length decoding for the BC412 symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different lengths may be set CBCLC00 BC412 Length Control Variable Length BC412 Length Control Fixed Length CBCLC01 ...

Страница 204: ...is length only one fixed length See Set Length 2 on page 248 for more detailed pro gramming instructions Select BC412 Length 1 Setting CBCL1 To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad represent ing your desired character s End by scanning the ENTER EXIT bar co...

Страница 205: ...TION POWER MANAGEMENT These parameters refer to Mobile units only either GBT4200 or GM4200 models SECTION CONTENTS POWER SAVE starting on page 192 Powerdown Timeout BATTERY PROFILES starting on page 193 Battery Profiles Battery Information ...

Страница 206: ...eature sets the time for automatically switching the unit off when the imager has been idle CSLPS00 Powerdown Timeout Disable Powerdown Timeout 10 minutes CSLPS01 CSLPS02 Powerdown Timeout 20 minutes Powerdown Timeout 30 minutes CSLPS03 CSLPS06 Powerdown Timeout 60 minutes 1 hour Powerdown Timeout 120 minutes 2 hours CSLPS0C ...

Страница 207: ...rge instead of battery health maximum read ing performance instead of battery autonomy etc The following Battery Profiles are described with associated benefits and limitations CBCHP00 Battery Profile Maximum Performance Battery Profile Maximum Battery Health CBCHP01 CBCHP02 Battery Profile Maximum Autonomy Battery Profile Fast Charge CBCHP03 Maximum Performance default Scanner autonomy for heavy ...

Страница 208: ...ging Status Charging Cradle Battery Voltage Battery Current Manufacturer Date Battery Serial Number Battery Model Number If more than one scanner is connected to a cradle battery data will be retrieved for each scanner Maximum Autonomy Max scanner autonomy approx 83h Motionix disabled Vibro motor disabled Reduced Radio Star responsiveness Increased Sniff time period Bluetooth Fast Charge Reduced r...

Страница 209: ...ATURES starting on page 202 Batch Mode Send Batch Erase Batch Memory Erase Batch Memory DIRECT RADIO AUTOLINK starting on page 204 Direct Radio Autolink RF ADDRESS STAMPING starting on page 205 RF Address Stamping Source Radio Address Delimiter Character BLUETOOTH ONLY FEATURES starting on page 206 Bluetooth Security Level Bluetooth Radio Output Power Wi Fi Channels Exclusion BLUETOOTH HID FEATURE...

Страница 210: ...nsmission Beep indication When enabled a beep occurs when a Label is correctly transmitted to the base Beeper Frequency Adjusts radio specific beep indications to sound at a low medium or high frequency selectable from the list below controls the beeper s pitch tone CBTAB00 Good Transmission Beep Disable Good Transmission Beep Enable CBTAB01 CBTBF00 Beep Frequency Low Beep Frequency Medium CBTBF01...

Страница 211: ...ure controls the duration of radio specific beep indications CBTBD06 Beep Duration 60 msec Beep Duration 80 msec CBTBD08 CBTBD0A Beep Duration 100 msec Beep Duration 120 msec CBTBD0C CBTBD0E Beep Duration 140 msec Beep Duration 160 msec CBTBD10 CBTBD12 Beep Duration 180 msec Beep Duration 200 msec CBTBD14 ...

Страница 212: ... radio specific beep indications There are three selectable volume levels Disconnect Beep Enables disables the beep indication that a handheld has become disconnected from a Base Station CBTBV00 Beep Volume Low Beep Volume Medium CBTBV01 CBTBV02 Beep Volume High CBTDB00 Disconnect Beep Disable Disconnect Beep Enable CBTDB01 ...

Страница 213: ...pecially useful in instances where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader must be linked to the Base Station If the reader is asleep or disconnected from the Base Station there is no way for it to know where it is relative to the Base Station because communication is not active between the devices CBTCB00 Docking Beep Disable Docki...

Страница 214: ...MODE WIRELESS FEATURES 200 GRYPHON I GD GBT GM4200 Leash Alarm continued CBTLB04 Leash Alarm 4 Seconds Leash Alarm 5 Seconds CBTLB05 CBTLB0A Leash Alarm 10 Seconds Leash Alarm 25 Seconds CBTLB19 CBTLB1E Leash Alarm 30 Seconds ...

Страница 215: ...pdate feature is disabled and you want a one time configuration update to be performed on the scanner Copy Configuration to Scanner Copy Configuration to Base Station Scan the following label to copy the current scanner configuration to the Base Station Use this method when the Auto Configuration Update feature is disabled and you want a one time configuration update to be performed on the Base St...

Страница 216: ...f range and is disconnected from the remote device Manual The handheld will always store labels to Flash memory The user must manually send the stored labels to the remote device using a special batch send label Send Batch When the scanner is configured in Manual Batch Mode use the following bar code to initiate sending of labels stored in batch memory Send Batch BatchSend CBTBM00 Batch Mode Disab...

Страница 217: ... Delay Specifies the delay in 10 msec increments between transmitting labels stored in batch memory NOTE Do not scan an ENTER EXIT PROGRAMMING MODE label in conjunc tion with this bar code CBTTD00 RF Batch Mode Transmit Delay No Delay RF Batch Mode Transmit Delay 50 ms CBTTD05 CBTTD0A RF Batch Mode Transmit Delay 100 ms RF Batch Mode Transmit Delay 0 5 seconds CBTTD32 CBTTD64 RF Batch Mode Transmi...

Страница 218: ...4200 DIRECT RADIO AUTOLINK Direct Radio Autolink This feature enables disables the ability to link a wireless handheld to a base station without scanning the Unlink label first CBTDL00 Direct Radio Link Unlink Label Required Direct Radio Link Automatic Unlinking CBTDL01 ...

Страница 219: ...r all label formatting has been applied The 6 byte hex address is sent as 12 ASCII characters i e an address of 00 06 66 00 1A ED will be sent as shown in hex 30 30 30 36 36 36 30 30 31 41 45 44 CBTAS00 Source Radio Address Transmission Do Not Include Source Radio Address Transmission Prefix CBTAS01 NOTE This feature only applies if Source Radio Address Transmission on page 205 is enabled Set Sour...

Страница 220: ...quest on page 23 to per form this task NOTE Changing the configuration parameters described in this section may cause a temporary loss of the Bluetooth connection between the Reader and the remote device NOTE This parameter applies when pairing the Reader with a third party Bluetooth device It has no effect when linking the Reader to a Base sta tion NOTE When device authentication takes place duri...

Страница 221: ... extend the battery life of the Reader and reduce the interferences caused to nearby wireless devices that operate in the same 2 4 GHz frequency band NOTE Changing the BT Security Level setting will unlink the Reader from the remote device CBTSL01 BT Security Level Level 1 lowest BT Security Level Level 2 CBTSL02 CBTSL03 BT Security Level Level 3 highest CBTPP00 Bluetooth Output Power Class 1 high...

Страница 222: ...nificant level of interference and avoid using these channels during Bluetooth data exchange If the specific 802 11 standard and the frequency channels used by the Wi Fi equipment are known select the corresponding combination from the list of pro gramming labels below or use the Datalogic Aladdin tool With this setting the Reader and the remote Bluetooth device avoid using the Bluetooth frequency...

Страница 223: ...F80000 WiFi Ch Exclusion 802 11b_g ch 5 CBTWF000000007FFFFF000000 WiFi Ch Exclusion 802 11b_g ch 6 CBTWF0000000FFFFFE0000000 WiFi Ch Exclusion 802 11b_g ch 7 CBTWF000001FFFFFC00000000 WiFi Ch Exclusion 802 11b_g ch 8 CBTWF00003FFFFF8000000000 WiFi Ch Exclusion 802 11b_g ch 9 CBTWF000FFFFFE00000000000 WiFi Ch Exclusion 802 11b_g ch 10 CBTWF00FFFFFE000000000000 WiFi Ch Exclusion 802 11b_g ch 11 ...

Страница 224: ...on 802 11b_g ch 13 CBTWF7F800000000000000000 WiFi Ch Exclusion 802 11b_g ch 14 CBTWF000000007FFFFF3FFFFF WiFi Ch Exclusion 802 11b_g ch 1 and 6 CBTWF00FFFFFE0000003FFFFF WiFi Ch Exclusion 802 11b_g ch 1 and 11 CBTWF00FFFFFE7FFFFF000000 WiFi Ch Exclusion 802 11b_g ch 6 and 11 CBTWF003FFFFC1FFFFC0FFFFF WiFi Ch Exclusion 802 11b_g ch 1 and 6 and 11 CBTWF0000000FFFFFE7FFFFF0 WiFi Ch Exclusion 802 11b_...

Страница 225: ...802 11b_g ch 7 and 12 CBTWF0FFFFF03FFFF81FFFFE0 WiFi Ch Exclusion 802 11b_g ch 2 and 7 and 12 CBTWF000001FFFFFCFFFFFE00 WiFi Ch Exclusion 802 11b_g ch 3 and 8 CBTWF7FFFF8000000FFFFFE00 WiFi Ch Exclusion 802 11b_g ch 3 and 13 CBTWF7FFFF9FFFFFC00000000 WiFi Ch Exclusion 802 11b_g ch 8 and 13 CBTWF3FFFF07FFFF07FFFFE00 WiFi Ch Exclusion 802 11b_g ch 3 and 8 and 13 CBTWF00003FFFFF9FFFFFC000 WiFi Ch Exc...

Страница 226: ...lusion 802 11b_g ch 4 and 14 CBTWF7F803FFFFF8000000000 WiFi Ch Exclusion 802 11b_g ch 9 and 14 CBTWF7F803FFFFF9FFFFFC000 WiFi Ch Exclusion 802 11b_g ch 4 and 9 and 14 CBTWF000FFFFFE3FFFFF80000 WiFi Ch Exclusion 802 11b_g ch 5 and 10 CBTWF0000000001FFFFFFFFFF WiFi Ch Exclusion 802 11n ch 3 CBTWF7FFFFFFFFE0000000000 WiFi Ch Exclusion 802 11n ch 11 ...

Страница 227: ...llowing parameters Setting Country Mode on page 49 Encoding Type on page 63 ALT Output Type on page 70 Keyboard Numeric Keypad on page 72 Keyboard Send Control Characters on page 72 Bluetooth HID Alt Mode Enable Disable the ability to correctly transmit a label to the host regardless of the Bluetooth HID Country Mode selected when Bluetooth HID Profile is configured Read the configuration command ...

Страница 228: ...he radio traffic number of read ers in the same area The selectable range for this feature is from 02 to 25 seconds See page 246 in References for detailed information and examples for setting this feature Set Radio Protocol Timeout CSTPT To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters...

Страница 229: ...s a good transmission as soon as the Base Station has sent the label to the host and host has replied with an acknowledge message CSTTX00 STAR Radio Transmit Mode ACK from Base Station STAR Radio Transmit Mode ACK When Sent to Host CSTTX01 CSTTX02 STAR Radio Transmit Mode ACK from Host NOTE ACK from host works only for RS 232 or USB COM interfaces with ACK NACK disabled If ACK from host is configu...

Страница 230: ...ove read either the High speed or Low speed programming label below to set the desired speed end by scanning the ENTER EXIT bar code again 3 place the Reader into the Base The Reader and the Base will now be linked at the new programmed speed This feature can also be programmed using the Datalogic Aladdin tool 1 set the STAR System Speed to High speed or Low speed through Aladdin 2 place an unlink...

Страница 231: ...scanning the ENTER EXIT bar code again 3 place the Reader into the Base The Reader and the Base will be linked and the new frequency handling strategy will be operational NOTE It is possible to configure the STAR system to use a fixed channel with different frequency from the default one Please contact Datalogic Technical Support for information about this feature Please refer to Table 4 on page 2...

Страница 232: ...0 Table 4 Supported combinations of STAR System Speed and STAR Frequency Agility configuration parameters SYSTEM SPEED FREQUENCY AGILITY FIXED CHANNEL DIFFERENT FROM DEFAULT 433 MHz Model Low Speed Yes Yes High Speed No No 910 MHz Model Low Speed Yes Yes High Speed Yes Yes ...

Страница 233: ...acter Delay ACK NAK Options ACK Character NAK Character ACK NAK Timeout Value ACK NAK Retry Count Disable Character Enable Character KEYBOARD INTERFACE on page 228 Wedge Quiet Interval Intercharacter Delay Intercode Delay DATA FORMAT on page 231 Data Editing Global Prefix Suffix Global AIM ID Label ID Character Conversion SCANNING FEATURES on page 239 Good Read LED Duration Scan Mode Scanning Acti...

Страница 234: ...is the most significant bit of each ASCII coded character Select the parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0 or 1 based on data to ensure tha...

Страница 235: ...ACTER DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit This completes the procedure See the following table for examples of how to set this feature Table 5 Intercharacter Delay Setting ...

Страница 236: ...uivalent for the desired charac ter value 3 Scan ENTER EXIT PROGRAMMING MODE to enter Programming Mode 4 Scan the bar code SELECT ACK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in Appendix D that represent the desired character value determined above The second charac ter will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to e...

Страница 237: ...ent the desired character value determined above The second character will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 7 NAK Character Setting Examples NOTE Setting to previously defined characters such as XON XOFF or host commands conflicts with ...

Страница 238: ... 5 Scan the appropriate two digits from the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 8 ACK NAK Timeout Value Setting Exam...

Страница 239: ...ad in Appendix D that represent the number which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 9 ACK NAK Retry Count Setting Examples NOTE If you make a mistake before the last chara...

Страница 240: ...the desired character value determined above The second charac ter will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 10 Disable Character Setting Examples NOTE Setting to previously defined characters such as XON XOFF or host commands conflicts wit...

Страница 241: ...epresent the desired character value determined above The second charac ter will cause a two beep indication 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 11 Enable Character Setting Examples NOTE Setting to previously defined characters such as XON XOFF or host commands confl...

Страница 242: ...ndix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit This completes the procedure to set the Wedge Quiet Interval See the table below for examples of how to set this feature Table 12 Wedge Quiet Interval Setting Examples NOTE This feature applies ONLY to the K...

Страница 243: ...s from the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 13 Intercharacter Delay Setting Examples NOTE This feature applies ON...

Страница 244: ... represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 14 Intercode Delay Setting Examples NOTE If you make a mistake before the last character scan the CANCEL ...

Страница 245: ...ry default settings for data editing is typically set to NONE A prefix or suffix may be applied only to a specified symbology reference Symbologies starting on page 111 or across all symbologies set via the Global fea tures in Configuration with Bar Codes starting on page 31 You can add any character from the ASCII Chart on page 288 from 00 FF on the inside back cover of this manual as a prefix su...

Страница 246: ... the ASCII Chart on page 288 in Appendix F to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 bar codes from Appendix D 4 If less than the expected string of 20 characters are selected scan the ENTER EXIT bar code to terminate the string 5 Scan the ENTER EXIT bar code once again to exit Programm...

Страница 247: ...ow followed by A modifier character the modifier character is symbol dependent Figure 24 AIM ID NOTE This feature enables disables addition of AIM IDs for all symbology types SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea a UPC A and UPC E labels are converted to EAN 13 when adding AIM IDs Code 128 GS1 128 C Code 39 and Code 32 A DataBar Omnidirectional DataBar Expanded e Codabar F Standard 2 of 5 S Int...

Страница 248: ... the USA and Europe Table 15 Label ID Pre loaded Sets SYMBOLOGY USA LABEL ID SET EU LABEL ID SET ASCII character Hex value ASCII character Hexadecimal value ABC Codabar S 530000 S 530000 CODABAR 250000 R 520000 Code 39 CIP Y 590000 Y 590000 Code 93 260000 U 550000 Code 11 CE 434500 b 620000 Code 128 230000 T 540000 Code 32 A 410000 X 580000 Code 39 2A0000 V 560000 Datalogic 2of5 s 730000 s 730000 ...

Страница 249: ...S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 UPCE E 450000 D 440000 UPCE P2 E 450000 H 480000 UPCE P5 E 450000 I 490000 OCR A o 6F0000 o 246F00 OCR B o 6F0000 p 247000 MICR o 6F0000 m 246D00 SYMBOLOGY USA LABEL ID SET EU LABEL ID SET ...

Страница 250: ...SCII Chart on page 288 on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID the chart indicates its associ ated hex characters as 3D Turn to Keypad in Appendix D and scan the bar codes representing the hex characters determined For the example given the charac ters 3 and D wo...

Страница 251: ...l ID Sym bology Selection starting on page 85 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 PH 5 Find hex equivalents from the ASCII table inside back cover then scan in these digits char acters using the bar codes in the section Keypad starting on page 275 f you make a mistake before the last char acter scan the CANCEL bar code...

Страница 252: ...AB12BA21 it would look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 characters Nothing is done with the last two character pairs since they are all FF To set Character Conversion 1 Scan the ENTER EXIT bar code 2 Scan the bar code for Character Conversion on page 90 3 Determine the desired string Sixteen ...

Страница 253: ...multiple reads of the same label while in this mode Trigger Pulse Multiple When the trigger is pulled continuous scanning is activated until Stand Mode Object Detection has elapsed or the trigger has been released and pulled again Double Read Timeout prevents undesired multiple reads of the same label while in this mode Flashing The reader flashes1 on and off regardless of the trigger status Flash...

Страница 254: ...t represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 17 Scanning Active Time Setting Examples NOTE If you make a mistake before the last character scan the C...

Страница 255: ...t represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See Table 25 for some examples of how to set this fea ture Table 18 Aiming Duration Time Setting Examples NOTE If you make a mistake before the last character scan the CAN...

Страница 256: ...e keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 19 Flash On Time Setting Examples NOTE If you make a mistake before the last c...

Страница 257: ...m the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set this fea ture Table 20 Flash Off Time Setting Examples NOTE If you make a mistake before the l...

Страница 258: ... SELECT GOOD READ LED DURATION SETTING 5 Scan the appropriate two digits from the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the following table for some examples of how to set this feat...

Страница 259: ...when address stamping is enabled Follow these instructions to select the delimiter character 1 Determine the desired character then find its hexadecimal equivalent on the ASCII Chart on page 288 A setting of 00 specifies no delimiter character 2 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 3 Scan the bar code SET SOURCE RADIO ADDRESS DELIMITER CHARACTER 4 Scan the approp...

Страница 260: ...COL TIMEOUT 5 Scan the appropriate two digits from the keypad in Appendix D that represent the duration which was determined in the steps above You will hear a two beep indi cation after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE barcode to exit Programming Mode This completes the procedure See Table 29 for some examples of how to set this fea ture Table 23 STAR Radio Protocol Timeo...

Страница 261: ...r example 0 00 5 05 20 20 etc 2 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 3 Scan the Select Length 1 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix D that represent the length setting which was determined in the steps above You will hear a two beep indication after the last character 5 Scan the ENTER EXIT PROGRAMMING ...

Страница 262: ...an the Select Length 2 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix D that represent the length setting which was determined in the steps above You will hear a two beep indication after the last character 5 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how ...

Страница 263: ... tained in the middle Messages cannot start with or because these are reserved for Service mode command Base station can receive host message only if Host Commands Obey Ignore is set to Ignore Message could be sent to the HH in response to a Label when Transmit mode require Ack from Host see transmit mode parameter or at any time When mes sages are sent not in response to a label must start with D...

Страница 264: ...ill be con trolled by the system after the entire command sequence is interpreted Example Escape sequences different from those listed will be ignored ESC SEQUENCE ACTION Esc 0 q Emit short High tone short delay Esc 1 q Emit short Low tone short delay Esc 2 q Emit long Low tone short delay Esc 3 q Emit good read tone Esc 4 q Emit bad tx tone Esc 5 q Wait 100 ms Esc 6 q Turn on the green LED Esc 7 ...

Страница 265: ...S Power Supply GD4220 5VDC 5 GD4290 4 5 14 0 VDC Consumption Operating Typical 350mA 5V 150mA 12V Standby Idle Typical 60mA 5V 30mA 12V Max Scan Rate 400 reads sec Reading Indicators Top and rear illumination Good Read Spot Beep OPTICAL CHARACTERISTICS Optical Format CCD solid state sensor 2500 pixels Illumination System LED Source Dual LED Array 612 630nm Ambient Light Up to 130 000 lux Tilt Tole...

Страница 266: ...S Color Black White Dimensions Height 16 6 cm 6 5 Length 10 9 cm 4 3 Width 6 8 cm 2 7 Weight without cable GD4200 approx 163 g 5 75 oz a Based on ISO 15423 specifications ELECTRICAL CHARACTERISTICS Power Supply WLC4190 4 5VDC 14VDC 5 Consumption Typical Gun Only 750mA Cradle Only 70mA Cradle with Gun in Charge 380mA PC host USB 1030mA 5V host Type C 400mA 12V on USB external powered cable Max Scan...

Страница 267: ...ture 0 C to 50 C 32 F to 122 F Storage Temperature 40 C to 70 C 40 F to 158 F Humidity 95 non condensing Drop Resistance IEC 68 2 32 Tested 1 8 m 6 ft ESD Protection 16 KV Protection Class IP52 Cable Length Refer to www datalogic com PHYSICAL CHARACTERISTICS Color Black White Dimensions Gun only L H P 68 4 x 165 8 x 110 0mm 2 7 x 6 5 x 4 3 Cradle only L H P 203 3 x 84 x 94mm 8 0 x 3 3 x 3 7 Gun on...

Страница 268: ...f field is defined by an arc and not a plane Shorter bar codes of a given resolution can be read at a further distance than longer bar codes as explained in the following image Code 39 5mils 50 to 370mm 1 97 to 14 6 inchb b All labels grade A typical environmental light 20 C label inclination 10 Code 39 7 5mils 50 to 540mm 1 97 to 21 3 inchb Code 39 10mils 50 to 735mm 1 97 to 28 9inchb Code 39 20m...

Страница 269: ...e 2 of 5 IATA 2 of 5 Air cargo code Follet 2 of 5 Codabar Codabar NW7 ABC Codabar Code 11 Code 93 MSI PZN Plessey Anker Plessey GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Truncated DATABAR Expanded Coupon INDICATION LED BEEPER Power up Upper LED flashes blinks on power up however this may be too rapid to view With a USB interface the LED blinks until enumeration with the host is complete...

Страница 270: ...ion 1 s default Reader Disabled POS Communication with host not established 100 ms ON 900 ms OFF Firmware Upgrade 250 ms ON 250 ms OFF Host Download 250 ms ON 250 ms OFF Enter Service Mode No Effect Label Programming No Effect STATUS 3GL AND GOOD READ LED BATTERY LED Power up OFF OFF USB Enumeration Phase 250 ms ON 250 ms OFF OFF USB Suspend Depends on Power Cable and specific configurations OFF I...

Страница 271: ...nsmission OFF OFF Cradle in USB Suspend Depends on Power Cable and specific configurations OFF Configuration Alignment 250 ms ON 250 ms OFF OFF Charge Fault OFF OFF Charge in Progress through Cradle OFF OFF Charge Complete through Cradle OFF OFF Battery Status indications when not charging using double tap OFF Solid with programmable duration 3 s default and then OFF Green charge 50 100 Amber char...

Страница 272: ...ation with host not established 100 ms ON 900 ms OFF OFF Firmware Upgrade 250 ms ON 250 ms OFF OFF Host Download 250 ms ON 250 ms OFF OFF Configuration Alignment 250 ms ON 250 ms OFF OFF Enter Service Mode No Effect remains Solid ON OFF Short button press 1 5 s Paging request Blink Green 500 ms ON 500 ms OFF for 5 s while pressing button OFF Long button press 6 10 s Flush Piconet request Blink Gre...

Страница 273: ...anner sounds one high fequency beep and four low fre quency beeps followed by reset beeps Cancel Item Entry Cancel label has been scanned N A Scanner sounds two times at low frequency current volume PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Nothing happens when the scan button is pulled No power to the imager Check system power Ensure power sup ply is connected Interface or power cables are loose E...

Страница 274: ...r s cable Figure 26 Standard Cable Pinouts The signal descriptions in Table 21 apply to the connector on the scanner and are for reference only Table 33 Standard Cable Pinouts Scanner Side PIN RS232 USB KEYBOARD WEDGE 1 RTS out 2 D CLKIN KBD side 3 D DATAIN KBD side 4 GND GND GND 5 RX 6 TX 7 VCC VCC VCC 8 CLKOUT PC side 9 DATAOUT PC side 10 CTS in ...

Страница 275: ...s Table 34 Standard Defaults PARAMETERS DEFAULT YOUR SETTING PAGE NUMBER GLOBAL INTERFACE FEATURES Host Commands Obey Ignore Obey 33 USB Suspend Mode Enable 33 RS 232 ONLY Baud Rate 9600 35 Data Bits 8 Data Bits 36 Stop Bits 1 Stop Bit 36 Parity None 37 Handshaking Control RTS 38 RS 232 USB COM Intercharacter Delay No Delay 40 Beep On ASCII BEL Disable 41 Beep On Not on File Enable 41 ACK NAK Opti...

Страница 276: ...3 Intercode Delay 00 No Wedge Intercode Delay 74 USB OEM USB OEM Device Usage Handheld 77 USB OEM Interface Options Ignore Scanner Configuration Host Commands 77 DATA FORMAT Global Prefix Suffix No Global Prefix Global Suffix 0x0D CR 81 Global AIM ID Disable 82 GS1 128 AIM ID Disable 82 Label ID Pre loaded Sets USA Set 83 Label ID Control Disable 84 Label ID Symbology Selection 85 Case Conversion ...

Страница 277: ...ODE SELECTION Code EAN UPC Coupon Control Enable only UPC EAN 112 UPC A UPC A Enable Disable Enable 113 UPC A Check Character Transmis sion Send 113 Expand UPC A to EAN 13 Don t expand 114 UPC A Number System Character Transmission Transmit 114 UPC E UPC E Enable Disable Enable 115 UPC E Check Character Transmis sion Send 115 Expand UPC E to EAN 13 Don t expand 116 Expand UPC E to UPC A Don t expa...

Страница 278: ...DD ONS Optional Add ons Disable P2 P5 P8 125 Optional Add On Timer 70 ms 126 GS1 DATABAR OMNIDIRECTIONAL GS1 DataBar Omnidirectional Enable Disable Disable 127 GS1 DataBar Omnidirectional to GS1 128 Emulation Disable 127 GS1 DataBar Expanded Enable Dis able Disable 128 GS1 DataBar Expanded to GS1 128 Emulation Disable 128 GS1 DataBar Expanded Length Con trol Variable 129 GS1 DataBar Expanded Set L...

Страница 279: ...isable 139 Code 32 Check Character Transmis sion Don t Send 139 Code 32 Start Stop Character Trans mission Don t Transmit 140 CODE 39 CIP French Pharmaceutical Code Code 39 CIP Enable Disable Disable 140 SPECIAL CODES Code 128 Code 128 Enable Disable Enable 141 Expand Code 128 to Code 39 Don t Expand 141 Code 128 Check Character Trans mission Don t Send 142 Code 128 Function Character Trans missio...

Страница 280: ...ard 2 of 5 Check Character Transmission Send 151 Standard 2 of 5 Length Control Variable Length 151 Standard 2 of 5 Set Length 1 08 8 characters 152 Standard 2 of 5 Set Length 2 50 50 characters 152 COMPRESSED 2 of 5 Compressed 2 of 5 Enable Disable Disable 153 Compressed 2 of 5 Check Character Calculation Disble 153 Compressed 2 of 5 Check Character Transmission Send 154 Compressed 2 of 5 Length ...

Страница 281: ...Industrial 2 of 5 Set Length 2 2 50 50 characters 161 CODE IATA IATA Enable Disable Disable 162 IATA Check Character Transmission Send 162 FOLLET 2 OF 5 Follett 2 of 5 Enable Disable Disable 163 CODABAR Codabar Enable Disable Disable 164 Codabar Check Character Calcula tion Disable 164 Codabar Check Character Transmis sion Send 165 Codabar Start Stop Character Transmission Transmit 165 Codabar Sta...

Страница 282: ...eck C and K 175 Code 11 Check Character Transmis sion Send 176 Code 11 Length Control Variable 176 Code 11 Set Length 1 04 4 characters 177 Code 11 Set Length 2 50 50 characters 177 CODE 93 Code 93 Enable Disable Disable 178 Code 93 Check Character Calculation Enable Check C and K 178 Code 93 Check Character Transmis sion Disable 179 Code 93 Length Control Variable 179 Code 93 Set Length 1 1 180 C...

Страница 283: ...Check Character Transmis sion Send 186 Plessey Length Control Variable 186 Plessey Set Length 1 01 one character 187 Plessey Set Length 2 50 50 characters 187 BC412 BC412 Enable Disable Disable 188 BC412 Check Character Calculation Calculate 188 BC412 Length Control Variable 189 BC412 Set Length 1 01 one character 190 BC412 Set Length 2 50 50 characters 190 PARAMETERS DEFAULT YOUR SETTING PAGE NUM...

Страница 284: ...l ID Character s C EAN 8 Label ID Character s B EAN 13 Label ID Character s A Code ISBN Label ID Character s A Code 39 Label ID Character s M MInterleaved 2of5 Label ID Character s I Code Standard 2 5 Label ID Character s H Codabar Label ID Character s N Code 128 Label ID Character s K GS1 128 Label ID Character s P Datalogic 2 of 5 Label ID Character s H ISBT 128 Label ID Character s K UPCE P2 La...

Страница 285: ...terleaved 2of5 Label ID Character s N Code Standard 2 5 Label ID Character s P Codabar Label ID Character s R Code 11 Label ID Character s b Code 128 Label ID Character s T GS1 128 Label ID Character s k UPCA P2 Label ID Character s F UPCA P5 Label ID Character s G UPCA GS1 128 Label ID Character s Q UPCE P2 Label ID Character s H UPCE P5 Label ID Character s I EAN8 P2 Label ID Character s J EAN8 ...

Страница 286: ...72 GRYPHON I GD GBT GM4200 APPENDIX C SAMPLE BARCODES The sample bar codes in this appendix are typical representations for their symbology types SAMPLE BARCODES 1D Barcodes UPC A EAN 13 Code 39 Code 128 ...

Страница 287: ...SAMPLE BARCODES PRODUCT REFERENCE GUIDE 273 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231 ...

Страница 288: ...r RSS GS1 DataBar variants must be enabled to read the barcodes below see GS1 DataBar Omnidirectional on page 127 GS1 Databar 14 GS1 DataBar Expanded 1234890hjio9900mnb GS1 DataBar Limited 08672345650916 GS1 DataBar Omnidirectional Truncated 55432198673467 ...

Страница 289: ...PRODUCT REFERENCE GUIDE 275 APPENDIX D KEYPAD Use the bar codes in this appendix to enter numbers as you would select digits charac ters from a keypad A B C D E F 0 ...

Страница 290: ...KEYPAD 276 GRYPHON I GD GBT GM4200 1 2 3 4 5 6 7 8 9 ...

Страница 291: ...haracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table Microsoft Windows Codepage 1252 see page 285 Single Press and Release Keys In the following tables Ar means Alt right pressed and Ar means Alt right released and so on Definitions for other keys a...

Страница 292: ...C S G BS HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F...

Страница 293: ... xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x ƒ ˆ Š Ś Œ 9x š œ ž Ÿ Ax NBSP ª Bx µ º Cx À Á Â Ã Ä Å Æ Ç È É Ê Ë Ì Í Î Ï Dx Ð Ò Ó Ô Õ Ö Ø Ù Ú Û Ü Ý Þ ß Ex à ...

Страница 294: ... A 090 A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 Home End Pg Up Pg Dwn Ar Ar Al Al Cl Cl Cr Ax Cr A 0161 A 0162 A 0163 A 0164 A 0165 A 0166 A 0167 A 0...

Страница 295: ...6 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142 A 0143 9x A 0144 A 0145 A 0146 A 0147 A 0148 A 0149 A 0150 A 0151 A 0152 A 0153 A 0154 A 0155 A 0156 A 0157 A 0158 A 0159 Ax A 0160 A 0161 A 0162 A 0163 A 0164 A...

Страница 296: ... C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 F13 F14 F15 F16 Cl Cl X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab à S ...

Страница 297: ...L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12 Enter...

Страница 298: ... x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del ...

Страница 299: ... S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 ...

Страница 300: ...4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del ...

Страница 301: ...252 PRODUCT REFERENCE GUIDE 287 MICROSOFT WINDOWS CODEPAGE 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the leg acy components of Microsoft Windows in English and some other Western languages ...

Страница 302: ... 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F a b c d e f g h i j k l m n o p q r s t u v w x y z DEL 60 61 62 63 64 65...

Страница 303: ......

Страница 304: ...ight no part of this documentation may be repro duced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission of Data logic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U www datalogic com 820119500 R...

Отзывы: