background image

 

 

 07

Datalogic Mobile S.r.l., 

Via S. Vitalino 13 

40012 - Lippo di Calderara 

Bologna - Italy 

dichiara che 
declares that the 
déclare que le 
bescheinigt ,daß das Gerät 
declare que el

 

 

F732- E

, Wizard Laser Terminal 

 
  

 

e tutti i suoi modelli 

   

 

and all its models 

 

 

et tous les modèles 

  und 

seine 

modelle 

 

 

y todos sus modelos 

 

sono conformi alle Direttive del Consiglio Europeo sottoelencate: 
are in conformity with the requirements of the European Council Directives listed below 
sont conformes aux spécifications des Directives de l’Union Européenne ci-dessous: 
den nachstehenden angeführten Direktiven des Europäischen Rats: 
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:

 

 

89/336/EEC EMC Directive

   e 

92/31/EEC

93/68 /EEC 

emendamenti successivi 

 and further 

amendments 

 

et 

ses successifs amendements 

 und späteren 

Abänderungen 

 y succesivas 

enmiendas 

 

Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica 
ed alla sicurezza dei prodotti. 
On the approximation of the laws of Member States relating to electromagnetic 
compatibility and product safety. 
Basées sur la législation des Etates membres relative à la compatibilité électromagnétique 
et à la sécurité des produits. 
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische 
Verträglichkeit und Produktsicherheit entsprechen. 
Basado en la aproximación de las leyes de los Países Miembros respecto a la 
compatibilidad electromagnética y las Medidas de seguridad relativas al producto.

 

Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: 
This declaration is based upon compliance of the products to the following standards: 
Cette déclaration repose sur la conformité des produits aux normes suivantes: 
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: 
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: 

 

EN 55022 (C

LASS 

A ITE), A

UGUST

 1994:

 

A

MENDMENT 

A1 (C

LASS 

A ITE), O

CTOBER 

2000:

 

L

IMITS AND METHODS OF MEASUREMENTS 

OF RADIO DISTURBANCE 
CHARACTERISTICS OF INFORMATION 
TECHNOLOGY EQUIPMENT 

 

 

 

EN 61000, O

CTOBER 

2001

E

LECTROMAGNETIC COMPATIBILITY 

(EMC) 
P

ART 

6-2: G

ENERIC STANDARDS 

I

MMUNITY FOR INDUSTRIAL 

ENVIRONMENTS

 

 
 
Lippo di Calderara, March 8th, 2007 
 
 
 Paola 

Chientaroli 

 

Quality Assurance Manager

 

Содержание F732-E Wizard

Страница 1: ... S r l 01 08 822000174 Rev E www mobile datalogic com Datalogic Mobile S r l Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 World wide Sales Network available from www mobile datalogic com contacts ...

Страница 2: ...vements without prior notification Datalogic Mobile shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic Mobile S r l 1997 200...

Страница 3: ...3 Application Development Programs 2 1 4 Package Contents 4 1 5 Accessories 5 2 CONNECTIONS 6 2 1 Cradle 6 2 2 Connection to the Host Computer 7 2 2 1 RS232 Connection 7 2 3 Connection Cable 9 3 USE AND OPERATION 10 3 1 Description of Keys Using EasyGen 11 3 2 Barcode Scanning 14 3 3 Downloading Data to Host 15 4 MAINTENANCE 16 4 1 Charging the Batteries 16 4 2 Replacing the Batteries 17 4 3 Clean...

Страница 4: ... through its website Log on to www mobile datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software Utilities including EasyGen Demo Version EasyGen Demo software allows developers to easily and quickly build personalized applications of average complexity in...

Страница 5: ... the specific F732 E terminal being used The use of cradles other than those supplied with the terminal or indicated in the list in par 1 4 could cause serious damage to the terminal Do not attempt to disassemble the F732 E terminal as it does not contain parts that can be repaired by the user Any tampering will invalidate the warranty When replacing the batteries or at the end of the operative li...

Страница 6: ...ON1 0mW EMITTEDWAVELENGTH630 680nm EN60825 1 2001 This product complies with 21 CFR Subchapter J CAUTION CLASS2LASERLIGHT WHENOPEN DONOTSTAREINTOBEAM This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause un...

Страница 7: ...2001 RAYO LÁSER NO MIRAR FIJO EL RAYO APARATO LÁSER DE CLASE 2 MÁXIMA POTENCIA DE SALIDA LONGITUD DE ONDA EMITIDA CONFORME A EN 60825 1 2001 ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 C...

Страница 8: ...i dirigere il raggio laser negli occhi di un osservatore anche attraverso superfici riflettenti come gli specchi DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein die von internationalen Behörden auferlegt wurden und sie beziehen sich auf den korrekten Gebrauch vom Terminal NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60...

Страница 9: ...rs des surfaces réfléchissantes miroirs par exemple ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción CDRH 21 CFR 1040 y EN 60825 1 No es ...

Страница 10: ... and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WEEE COMPLIANCE Informazione degli utenti ai sensi della...

Страница 11: ...n about disposal contact the supplier that provided you with the product in question or consult the dedicated section at the website www mobile datalogic com Information aux utilisateurs concernant la Directive Européenne 2002 96 EC Au terme de sa vie utile le produit qui porte le symbole d un caisson à ordures barré ne doit pas être éliminé avec les déchets urbains Éliminer ce produit selon cette...

Страница 12: ...onde lo compró o consultar la sección dedicada en el Web site www mobile datalogic com Benutzerinformation bezüglich Richtlinie 2002 96 EC der europäischen Kommission Am Ende des Gerätelebenszyklus darf das Produkt nicht über den städtischen Hausmüll entsorgt werden Eine entsprechende Mülltrennung ist erforderlich Beseitigung des Produkts entsprechend der Richtlinie verhindert negative Auswirkunge...

Страница 13: ...GENERAL VIEW B C D E E A Figure 2 F732 E Terminal Overview Key A Laser beam output window B Reset key protected C Two color LED D Cradle communications window E Battery charger contacts xiii ...

Страница 14: ...the CD onto your PC 5 Load an application program onto the F732 E terminal through the F952 cradle using either EasyGen or SysTools 2001 see par 1 3 of this manual for descriptions of the various application development programs available Since the EasyGen interpreter program is pre loaded onto the F732 E terminal you can easily get started by loading one of the example application programs from t...

Страница 15: ...th a handy 25 key alphanumeric keyboard and has a large LCD graphic backlit display with icons The display of 16 characters by 4 lines plus a line in the upper part of the display for the programmable icons is shown below The battery charge status Time F732 E WIZARD LASER MICRO TERM DATALOGIC S P A 4 LINES 16 CHARS The icons which can be controlled by the application program Figure 3 Terminal Disp...

Страница 16: ...ion inventory goods picking assisted sales available in 5 languages English French German Italian Spanish The complete documentation in PDF format 1 3 APPLICATION DEVELOPMENT PROGRAMS By using the optional EasyGen Application Generator or the DS for Formula software packages developers can easily customize applications according to the end user specific needs solving the most common data collectio...

Страница 17: ...or The libraries developed by Datalogic Mobile permit direct management of the terminal functions For example the management of barcode reading devices is immediate and rational thanks to interaction with functions that automatically start up the barcode acquisition procedure Equally transparent by using a philosophy of events programming is the procedure managing the keyboard display serial and r...

Страница 18: ...UTION Remove all components from their packing and check that they are in good condition and that they correspond to the shipment documents Keep the packing and boxes in case it is necessary to send the terminal back for technical assistance Damage caused by improper packing is not covered by the warranty NOTE Rechargeable battery packs are not initially charged Therefore the first operation to pe...

Страница 19: ...lt Holster order number 94ACC1268 F732 E Holster with swivel Rubber Cover order number 94ACC4650 Rubber Protection Cover DS for Formula order number 94A104860 Development system for Formula Basic Line CA51 order number 94A104890 C Compiler 8051 Compiler kit V7 for F6XX and F7XX EasyGen order number 94A104850 Easy application generator package for Formula batch terminals F660 E F725 E F732 E Wizard...

Страница 20: ...ost computer with an available RS232 serial line The following figure describes the F952 cradle A B C D Figure 4 F952 Cradle Overview A Red Green LED Green terminal not inserted or charge level being maintained Red charge in progress B Cradle on off switch C Power jack 9 V D RJ connector for connection to the host computer CAUTION The use of cradles other than those expressly specified may damage ...

Страница 21: ...RS232 port of the cradle point D in the previous figure 3 Insert the power supply plug into the jack on the base of the cradle point C in the previous figure 4 Attach the power supply to a power outlet 5 Turn on the cradle point B in the previous figure and the computer 6 Put the F732 E terminal into the cradle and if necessary wait for battery recharging NOTE For correct communication with the te...

Страница 22: ...F732 E WIZARD 2 C D B A Figure 5 RS232 Single Cradle Connection Key A Host computer B Serial cable C F952 cradle D Power supply 8 ...

Страница 23: ...llowing characteristics RS232 Connection with PC AT or compatible cable 94A054000 included with terminal TX RTS GND CTS RX 1 2 3 4 5 2 8 5 7 3 4 1 RJ45 Cradle side Host PC side 9 pin D sub female Figure 6 RS232 Cable Pinout Other cables are available depending on the type of computer and connection 9 ...

Страница 24: ... onto the terminal to exploit its features By using the optional EasyGen Application Generator or the DS for Formula software package developers can easily customize applications according to the end user specific needs solving the most common data collection applications such as inventory picking and shipping receiving The Demo Version of EasyGen is included on CD together with 5 ready to use exa...

Страница 25: ...pplication Generator CAUTION Refer to chapter 6 EasyGen Interpreter Program of the EasyGen User s Manual for more details about the key functions NOTE Every time a key is pressed the F732 E terminal remains turned on for a maximum of 20 seconds ARROW KEYS only available for the application when not in Select or Data Edit mode SCAN KEY activates the laser for barcode scanning and turns on the F732 ...

Страница 26: ...SHIFT 2 and so on The fourth time the SHIFT key is pressed the SHIFT function is disabled The SHIFT function can also be disabled by waiting for a time out of 2 seconds after being pressed By pressing the SHIFT key followed by the RIGHT ARROW key the graphic display s contrast increases to the allowed maximum and then returns to 0 value NUMERIC KEYS allow the entry and display of the main numeric ...

Страница 27: ...USE AND OPERATION 3 ENTER KEY allows validation of what has been typed PROTECTED RESET KEY it is activated by inserting a blunt object in the slot while simultaneously pressing the SCAN key 13 ...

Страница 28: ...d by the laser must completely cover the barcode the LED and the acoustic signal if activated will indicate if the scan was carried out correctly NO NO OK OK Figure 7 F732 E Terminal Scanning a Barcode NOTE Throughout the operation of the application the battery icon and the time icon will always be activated the latter in accordance with the setting of the terminal internal clock 14 ...

Страница 29: ...software allows downloading data onto the PC by simply inserting the terminal into the cradle or by direct operator intervention on the terminal or host computer For EasyGen Applications the SysTools 2001 utility program is provided to download data collected from the terminal onto the PC See the SysTools 2001 User s Manual for more details Figure 8 Downloading Data with F732 E 15 ...

Страница 30: ... one which warns of pre low battery icon empty and intermittently flashing Recharging should be made after using the terminal until the batteries are nearly flat CAUTION When the terminal display window shows the message BATTERY LOW wait until the it is turned off before inserting it in the cradle Recharge the terminal by simply inserting it into its cradle Datalogic Mobile S r l recommends a mini...

Страница 31: ...eached due to the battery increased capacity CAUTION If the terminal remains inactive for a prolonged period such as two weeks it is advisable to download all the stored data onto a computer and extract the battery pack 4 2 REPLACING THE BATTERIES CAUTION Before proceeding ensure that the terminal is switched off and that the data it contains has been downloaded onto the host computer To replace t...

Страница 32: ...Before inserting the battery pack into the terminal ensure the battery polarity matches with the one indicated within the case CONTACTS Figure 9 Figure 10 CAUTION When inserting the battery pack first slide it towards the springs compressing them until the contacts at the other end are cleared see Figure 9 Then push downwards to insert the pack see Figure 10 Be very careful not to damage the conta...

Страница 33: ...temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect type Dispose of the batteries as required by the relevant laws in force 4 3 CLEANING THE TERMINAL Clean the terminal from time to time with a slightly damp cloth Do not use alcohol corrosive products or solvents 19 ...

Страница 34: ...y and switch on the cradle The serial cable is not correctly connected Check the connection to the cradle and the serial port of the computer The terminal does not load the application program The terminal already contains an application program Follow instructions to cancel the application The application loaded is not suitable for the terminal in use The terminal displays the message FAULT CODE ...

Страница 35: ... h batteries Battery charger Formula 952 Physical Features Technology SMT Surface Mount Technology Dimensions LxWxH 165 x 56 x 32 mm 6 5 x 2 2 x 1 26 in Weight 184 gr 6 49 oz Buzzer Piezoelectric programmable in frequency and duration LED Programmable red green LED Display High contrast back lit LCD graphic display with 97 x 32 matrix Keyboard 25 silicone rubber keys reset button Environmental Fea...

Страница 36: ... UPC A EAN 13 only Codabar NW7 Monarch 2 7 PAKO Code 128 EAN 128 Delta A IBM MSI Code 93 Zellweger Storagetek Operating modes bootstrap loader application program Transmission Features F952 interface via optical transceiver with serial protocol Cradle Host interface RS232 Transmission speed 300 to 19200 bits sec Transmission protocol Program definable Transmission modes Full duplex Parity Mark spa...

Страница 37: ...er second Byte On an addressable boundary eight adjacent binary digits 0 and 1 combined in a pattern to represent a specific character or numeric value Bits are numbered from the right 0 through 7 with bit 0 the low order bit One byte in memory can be used to store one ASCII character Decode To recognize a barcode symbology e g Codabar Code 128 Code 3 of 9 UPC EAN etc and analyze the content of th...

Страница 38: ... to their bias They use little electricity and react relatively quickly They require external light to reflect their information to the user Light Emitting Diode LED A low power electronic light source commonly used as an indicator light It uses less power than an incandescent light bulb but more than a Liquid Crystal Display LCD RAM Random Access Memory Data in RAM can be accessed in random order...

Страница 39: ...the Terminal 18 Connections 6 Cradle 6 RS232 Connection 7 D Description of Keys 10 Downloading Data 14 G General View xiii Glossary 22 M Maintenance 15 Q Quick Start xiv R Reference Documentation iv Replacing the Batteries 16 T Technical Features 20 Terminal Description 1 Troubleshooting 19 U Use and Operation 10 25 ...

Страница 40: ...electromagnetic compatibility and product safety Basées sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad elec...

Страница 41: ... S r l 01 08 822000174 Rev E www mobile datalogic com Datalogic Mobile S r l Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 World wide Sales Network available from www mobile datalogic com contacts ...

Отзывы: