DX8200A-3002 QUICK GUIDE
6
Example Redundant Reading Station
ELECTRICAL CONNECTIONS
Two 17-pin connectors provide access to the scanner’s local Lonworks network used for both input and output
connections to build a multi-sided or omni-station system.
17-pin Lonworks Connector Pinout
Pin Name
Function
A1
GND
Supply voltage (negative pin)
A2
VS
Supply voltage 20 to 30 Vdc (positive pin)
Cable shield A - internally connected by
1 CHASSIS
capacitor to chassis
2 n.c.
Not
connected
Cable shield B - internally connected by
3 CHASSIS
capacitor to chassis
4 TXAUX
Transmit data of auxiliary RS232
(referred to SGND)
5
SGND
Signal ground (connected to GND)
6 RXAUX
Receive data of auxiliary RS232
(referred to SGND)
7
VS_I/O
Supply voltage of I/O circuit
8
Lon A+
Lonworks a line (positive pin)
9
Lon A-
Lonworks a line (negative pin)
10
Lon B+
Lonworks b line (positive pin)
11
Lon B-
Lonworks b line (negative pin)
12 SYS_I/O
System
signal
13 SYS_ENC_I/O System
signal
14 Reserved
Internally
connected
15 Ref_I/O
Reference voltage of I/O circuit
A1
A2
1
15
Female - Output
A1
A2
1
15
Male - Input
17-pin Local Lonworks Connectors
Conveyor
SC6000
Working
A
H
G
C
D
B
E
F
PWO
SC6000
Protecting
PWO