DX8200A-3002 QUICK GUIDE
10
Once the scanner is correctly positioned for PackTrack, fix the stops against the scanner. The stops remain
fixed to the station frame so that the scanner can be replaced without having to recalibrate the PackTrack
coordinates. Referring to the figure above, the stop provides a reference point for the X-axis while the scanner
should be centered on the frame to have a fixed reference for the Y-axis.
SCANNER DIRECTION
The different scanner orientations are illustrated in the following figures:
DX8200A-3002 Scanner Direction 0° (Forward)
DX8200A-3002 Scanner Direction 180° (Reverse)
READING DIAGRAMS
Note:
x = 0 and z = 0 correspond to the edge of the DX8200A-3002 scanner as shown in the figure below.
DX8200A-3002 (0.50 mm/20 mils)
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
0
-24
-40
(in)
-32
-48
0
-60
-80
(cm)
-100
-120
-140
-160
-56
-64
(in)
-30
-20
0
-10
(cm)
-50
-60
-70
-40
30
20
10
50
60
70
40
-12
-8
0
-4
-20
-24
-28
-16
12
8
4
20
24
28
16
-40
-15
z
x
Top View
Conveyor Direction
Top View
Conveyor Direction