INSTALLATION – DS8100 SERIAL INTERFACE
25
2
Signal
INPUT DEVICE
+
-
10/12/14
11/13/15
+
DS8100
V
Vext
Figure 26 - NPN input command using external power
Isolation between the command logic and the scanner is maintained by powering the
inputs with a different supply voltage (Vext) from that supplied on the
Aux.
Interface/Input Signal A
and
B
connectors (VS).
The driving logic of the input signals may be powered, for convenience, with the
voltage supply between pins A2 (VS) and A1 (GND) of the connector. In this case,
however, the device is no longer electrically isolated.
The electrical features of these inputs are:
Maximum voltage
30 V
Maximum current
25 mA
2.4.6 Outputs
The relative signals are available on the Output Signal connector (Figure A, 16).
Pin
Name
Function
1
VS
power for external devices (Positive pin)
2
GND
power for external devices (Negative pin)
3
NO READ+
no read
4
NO READ-
no read output -
5
RIGHT+
right code
6
RIGHT-
right code output -
7
8
SPS+
SPS-
slave presence
slave presence sensor -
9
N.C.
not connected
A D.C. output voltage, the same as that powering the DS8100, is present between pins
1 and 2. This may be used to power external devices: electrical isolation between the
scanner and external devices is lost in this case.
Содержание DS8100
Страница 1: ...DS8100 Installation Manual ...
Страница 2: ...DS8100 Installation Manual ...
Страница 3: ...DS8100 INSTALLATION MANUAL ...
Страница 11: ...ix DS8100 Figure C DS8100 Oscillating Mirror version Laser Beam Output Window 1 1 ...
Страница 55: ...INSTALLATION DS8100 BUS INTERFACE 41 3 CONVEYOR SC8000 Figure 47 DS8100 Bus Interface typical application ...