INSTALLATION – DS8100 SERIAL INTERFACE
11
2
2.2.2 Multidrop
Address
Selection
When using the RS485 half-duplex interface, the Multidrop Address must be
selected. Proceed as follows:
1. Open the panel as described in par. 2.2.
2. Position the switches as desired, referring to Figure 8.
DISPLAY
DIP SWITCH
ON
1
2
3
4
5
DIP
Figure 8 - DS8100 Multidrop Address selection
The following table shows the Multidrop Address settings where:
1 = ON
0 = OFF
Position
Address
Position
Address
5
4
3
2
1
5
4
3
2
1
1
1
1
1
1
31
0
1
1
1
1
15
1
1
1
1
0
30
0
1
1
1
0
14
1
1
1
0
1
29
0
1
1
0
1
13
1
1
1
0
0
28
0
1
1
0
0
12
1
1
0
1
1
27
0
1
0
1
1
11
1
1
0
1
0
26
0
1
0
1
0
10
1
1
0
0
1
25
0
1
0
0
1
9
1
1
0
0
0
24
0
1
0
0
0
8
1
0
1
1
1
23
0
0
1
1
1
7
1
0
1
1
0
22
0
0
1
1
0
6
1
0
1
0
1
21
0
0
1
0
1
5
1
0
1
0
0
20
0
0
1
0
0
4
1
0
0
1
1
19
0
0
0
1
1
3
1
0
0
1
0
18
0
0
0
1
0
2
1
0
0
0
1
17
0
0
0
0
1
1
1
0
0
0
0
16
0
0
0
0
0
0
Содержание DS8100
Страница 1: ...DS8100 Installation Manual ...
Страница 2: ...DS8100 Installation Manual ...
Страница 3: ...DS8100 INSTALLATION MANUAL ...
Страница 11: ...ix DS8100 Figure C DS8100 Oscillating Mirror version Laser Beam Output Window 1 1 ...
Страница 55: ...INSTALLATION DS8100 BUS INTERFACE 41 3 CONVEYOR SC8000 Figure 47 DS8100 Bus Interface typical application ...