DS2100
12
2
DS2100 25-pin
TX485+
2
TX485-
4
RX485+
3
RX485
RX485-
5
TX485
7
SGND
SGND
USER INTERFACE
+
-
+
-
+
Earth
Ground
Figure 9 - RS485 full-duplex connections
RS485 Half-Duplex Interface
The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.
It can be used in a master/slave layout or for Multidrop connections with a Datalogic
Multiplexer, (see par. 2.5.4 and 2.5.5) exploiting a proprietary protocol based on
polled mode called MUX32 protocol, where a master device polls slave devices to
collect data.
The connector pinout follows:
Connector
Name
Function
25-Pin
2
RS485 transmitted/received data +
4
RTX485-
RS485 transmitted/received data -
7
SGND
signal ground
2
RTX485 -
4
RTX485 -
7
SGND
MULTIPLEXER
RS485REF
DS2100 25-pin
Figure 10 - RS485 half-duplex connections
This interface is forced by software when the protocol selected is MUX32 protocol.