INSTALLATION
7
2
2.3 ELECTRICAL
CONNECTIONS
Several DS2100 models are equipped with a cable terminated by a 25-pin female D-
sub connector for connection to the power supply and input/output signals. The
details of the connector pins are indicated in the following table.
CAUTION
Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.
Figure 4 - 25-pin female D-sub connector
25-pin D-sub connector pinout
Pin
Name
Function
13
VS
Power supply input v
25
GND
Power supply input voltage -
1
CHASSIS
Chassis Ground
9
VS
External Trigger
supply v
18
EXT TRIG+
External T
19
EXT TRIG-
External Trigger -
8
OUT1 +
Output 1 +
11
OUT2 +
Output 2 +
12
OUT REF
Output reference
22
OUT REF
Output reference
20
RXAUX
Auxiliary RS232
21
TXAUX
Auxiliary RS232
23
CTSAUX
Auxiliary handshake RS232
24
RTSAUX
Auxiliary handshake RS232
6, 10, 14, 15,
16, 17
NC
Not Connected