DS2 Ethernet
Instruction Manual
22
Fig. 13
With the
Short Protocol
, the
Measurement Analysis
will be limited to the
Measure 1
. Notice that the
check box remains disabled (greyed) until the binary transmission and one of the following measures
are selected:
Top Beam (darkness or light)
Bottom Beam (darkness or light)
Middle Beam (darkness or light)
Total Beam (darkness or light)
Total Contiguous Beam (darkness or light)
Number of the Transitions (darkness or light)
When the
Output Hold
option is enabled and for all of the time the HOLD input remains active
(external TEACH-IN), the PNP/NPN and the analogue output are driven with the maximum detected
value of the Top Beam Dark measure. This option is available in the
Remote Programming
mode only.
The external TEACH-IN input maintains its functionality in the
Local Programming
mode.
The icon button
placed at bottom on the right of the panel enables the function Stop Scanning. It
interrupts or activates the scanning cycle by means of a voltage applied to the TEACH-IN input: 0VDC
scanning interrupted, 24VDC scanning activated.
When the Stop Scanning function is enabled, the button changes to
and all the others functions
associated with the TEACH-IN input are inhibited (remember that the TEACH-IN is a multifunction
input).
During the period of time that the scanning cycle remains stopped, the receiver’s outputs (digital and
analogue) maintain the previous state before the interruption. The transmitter indicates the absence of
the synchronism signal instead.