Instruction
Manual
DataVS1
Series
25
Duration
this indicates the length of time (in ms) the output must maintain the last acquired
value; this is mainly used for Part Present, Part Pass and Part Fail modes.
Delay
indicates after how long the output shall display the last acquired result. It delays the
time the output signal is maintained if the delay is longer than the processing time, therefore
from when the image is acquired to when the outputs are enabled.
These two parameters can be set using the
LEFT/RIGHT ARROW
buttons.
Once the settings have been completed, it is possible to return to the System menu and save the
modifications by pressing the
TEACH
button. Press
ESC
if you wish to exit without saving the
modifications. The system will display save request message. To confirm exit and ignore the
modifications, use the
ARROWS
to reach
NO
and press
SET
.
The configuration phase has been concluded when all the output settings have been completed. Now
you must render the modifications permanent and save the inspection to the sensor databank.
Select the
LOAD/SAVE
option from the main menu, and press the
SET
button.
It is possible to manage the sensor memory slots from the new menu displayed on the screen.
DataVS1 has a total of 8 databank areas where it is possible to save 8 different inspections which can
be recalled as required.
To save the configured inspection, select the destination databank using the
ARROW
buttons and
then press
SET
to confirm. Then move the cursor to
SAVE
and press
SET
.
On completing these configuration procedures, the user can:
disconnect the VSC and use the sensor in stand-alone mode
use the VSC to view the results of the inspection. To do this, enter the System menu and
press the
ESC
button to return to Monitor mode