2.7 REDS PARAMETERS CONFIGURATION
2.7.1 Master Working Controller REDS configuration
After the Net and Scanner setting, complete the Working configuration as follow:
1.
Redundancy Parameters
Reds Functionality = checked
.
2.
Redundancy Parameters
Topology Redundancy = Master Working
.
3.
Data Communication settings
Built-in Ethernet
Line Parameters
IP_address
Active = insert the IP address of your Master Working
.
4.
Data Communication settings
Built-in Ethernet
Line Parameters
IP_address
Stand-by = insert the IP address of your Master Protecting
.
NOTE
The IP_address Active must be different to the IP_address Stand-by.
The two IP_address must be on the same sub-net.
5.
Data Communication settings
Built-in Ethernet
Line Parameters
IP_netmask
= insert the IP netmask
.
6. If it is necessary set parameter:
Data Communication settings
Built-in Ethernet
Line Parameters
IP_ gateway = insert the IP gateway
.
7. If it is necessary set parameter:
Data Communication settings
Built-in Ethernet
Line Parameters
IP_ dns1 = insert the IP dns1
.
8. If it is necessary set parameter:
Data Communication settings
Built-in Ethernet
Line Parameters
IP_ dns2 = insert the IP dns2
.
For the use of WebSentinel it’s necessary to set the parameters below:
9.
Data Communication settings
Built-in Ethernet
Services
SentinelClient
Enable = checked
.
10.
Data Communication settings
Built-in Ethernet
Services
UserSocket#3
Status = checked
.
NOTE
When an UserSocket# is used with WebSentinel, Data Tx must be
unchecked.