DKM-250 User Manual V-2.0
42
Supply Input:
19-150VDC
Power Consumption:
< 4W
Voltage Measurements Inputs:
0-70V Input Sensitivity: 0.02V
70-150V Input Sensitivity: 0.40V
Current Measurement Input:
Measurement range:
-100 to +100mV.
Accuracy:
% 0.2
Isolation:
1000V AC, 1 minute
Internal Current Shunt Option:
Measurement range:
0-15A
Analog Output:
0-20mA
Analog Output Precision:
16 bit
Digital Input Range:
19 to 150VDC
Relay Outputs:
5 Amps @ 28VDC
Serial Port:
Signal type:
RS-485
Protocol:
Modbus RTU
Data Rate:
2400-38400baud
Isolation:
1000V AC, 1 minute
Operating Temp. Range:
-20°C...+70 °C (-4°F...158°F)
Max. Relative Humidity:
%95 non-condensing
Protection Degree:
IP 65 (Front panel, w. gasket)
IP 30 (Back panel)
Enclosure:
Flame retardent, ROHS compliant high temperature ABS/PC (UL94-V0)
Installation:
Flush mounting with rear brackets
Dimensions:
102x102x53mm (WxHxD)
Panel Cutout:
92x92mm
Weight:
200 gr
EU Directives:
2014/35/EC (LVD)
2014/30/EC (EMC)
Reference Standards:
EN 61010 (safety)
EN 61326 (EMC)
DATAKOM Elektronik Ltd.
Tel: +90-216-466 84 60 Fax: +90-216-364 65 65 e-mail: [email protected] http: www.datakom.com.tr