DKG-119J User Manual V-32
(09.07.2012)
- 22 -
The unit is able to send SMS messages in fuel theft or fuelling conditions.
These SMS messages are sent without creating visible fault condition.
These features are enabled by setting the program parameter
Engine Parameters > Fuel
Consumption / Hour
to a value other than 0%.
The
Fuel Consumption / Hour
parameter should be set to a value clearly greater than the
maximum fuel consumption of the engine.
If the fuel level measured from the sender input is decreased more than this parameter in 1
hour period, then a FUEL THEFT sms message is sent to programmed telephone numbers.
If the fuel level measured from the sender input is increased more than this parameter in 1
hour period, then a FUELLING sms message is sent to programmed telephone numbers.
The unit offers possibility of updating the firmware in the field. The firmware is updated through
the logic level serial port using Rainbow or a special DOS program.
The unit will go to firmware download mode with a special command from the PC program. In
download mode, the display of the unit will show “
DL-V1.00
”
During firmware update process, the progress is visible through a completion bar on the
screen.
The firmware update operation will take around 3 minutes.
After completion of the update a special command will set back the unit to normal operation
mode.
A logic level to RS-232 converter is necessary
in order to connect the unit to modem.
6.20 Firmware Update
6.19 Fuel Theft / Fuelling Messages