background image

 

Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG25  Ver. B  Publish:2008.08.01                                                             Page: 1/ 3

 

 

The Digital Keyless Entry system 

Operation User's Manual 

 

 

 

 

 

1.  Product Characteristic: 

‹

 

Allows up to 49+50 PIN codes 

‹

 

Dual relays programmable On/Off or pulsed or latched mode  

‹

 

Fully Programmable via keypad and master code 

‹

 

Door Reed Switch Input for Anti-Trailing 

‹

 

3 LED display with audible indication 

‹

 Non-Volatile 

Memory 

 

‹

 

Invalid PIN Lock-out  

‹

 

Durable Stainless Steel housing 

‹

 

With vandal resistant screws 

 
 

2. Specifications: 

‹

 

Operating Voltage: 12~24 Vdc 

‹

 

Current Draw: Average 15mA, Peak 60mA @ 12Vdc  

‹

 

Input:  request-to-exit

Door Reed 

‹

 

Output: Dual relays, N.O./N.C./Com. Output (free voltage contact)       

‹

 

Relays Electric Current: 2A MAX @30Vdc 

0.4A @ 120Vac  

‹

 

Relay Activation Time: 

(*

100

、*

200

 

„

 

Strike Time: 1~99 seconds

adjustable

 

„

 

Strike mode: Access Timer or Latch 

‹

 

Memory Volume: 49+50 PIN codes   

„

 

Relay 1 is controlled by 001~049 user slots 

„

 

Relay 2 is controlled by 050~099 user slots 

‹

 

PIN codes: 5 digit codes only                             

‹

 

Operating Temperature: -20~+70

 

‹

 

Ambient Humidity: 5~95% relative humidity non-condensing 

‹

 

Factory Master Code: 12345 

‹

 

Invalid PIN Lock-out: The system will shut down for 60 seconds while 32 codes of 
incorrectly Master Codes enrolled or PIN codes attempted. 

‹

 

EPROM:  Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 

 

Отзывы: