3. The indicator signal chart:
Sound and LED indicator:
Green LED
Power on, stand-by
Red LED
Relay 1 activated
LED signal
Yellow LED
Relay 2 activated
1 Beep
Effective PIN codes
2 Beeps
Entering
、
Exiting from the Program mode
3 Beeps
Data computing error
、
other operation mistakes
Sound signal
5 Beeps
Master Code reset to Factory
(
12345
)
4. Operation Instruction:
Enter Program Mode:
1. Compose twice the master code (Factory master is
「
12345
」
)
→
2 beeps
→
you are now in the "programming mode".
2. After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 32 wrong codes attempts at the
master code the lockout facility will operate.
Exiting from the program mode:
1. Press
「
#
」
to exit from the programming mode.
2. After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 32 wrong codes attempts at the
master code the lockout facility will operate.
Add PIN codes
Enter the Programming mode, Enter the slot position code
「*
001~
*
099
」
→
?????
Input 5 digit PIN codes
→
(beep) enrolled
Æ
(
repeat
)
Press
「
#
」
to exit from the programming mode, or program other operating.
Note 1:
The codes
「
00000
」
,
「
12345
」
or master code are not be used for PIN code.
Note 2:
Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099
user slots
To Delete a User Code
:
Enter the Programming mode
→
Press the slot position code of your choice to delete
(example "06")
→
Press
「*
006
」
→
「
00000
」
→
(
beep
)
→
delete
→
Press
「
#
」
to exit
from the programming mode, or programming other operating.
To Program Relocking Timer
Enter the Programming mode,
A. Relay
1
:
Press
「*
100
」
Followed by the number of seconds the relay should
open
→
「
05
」
=5 seconds
(
01 ~99 = seconds
)
→
(
beep
)
→
enrolled
→
Press
「
#
」
to exit from the programming mode, or program other operating.
B. Enter
「
00
」
Sets the relay to latching mode.
(Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).
C. Relay
2
:
Press
「*
200
」
Followed by the number of seconds the relay should
open
)
→
「
05 =5 seconds (01 ~99 = seconds).
→
(
beep
)
→
enrolled
→
Press
「
#
」
to exit from the programming mode, or program other operating.
D. Enter
「
00
」
Sets the relay to latching mode.
(Correct code entered opens the relay,
and the relay stays open until the correct code is entered again).