MA1044 MAQ20-RTD31/-RTD41 Hardware User Manual
Page 10 of 38
For troubleshooting purposes, reset status, communications errors, and invalid data written to a
module are monitored and made available to the user. Module diagnostic registers starting at module
register address 1900 hold this information.
Table 3: MAQ20-RTD41 Address Map Excerpt
– Status Registers
Address Range 1900 - 1999 : Status Registers
Start
Address
Read/
Write
Number of
Registers
Contents
Description
Data Range
Data
type
1900
R/W
1
Watchdog Flag
1 = Watchdog Reset, 0 = Normal
0 or 1
INT16
1902
R/W
1
I2C Error
I2C TX Error Counter
0 to 65,535
INT16
1903
R/W
1
I2C Error
I2C RX Error Counter
0 to 65,535
INT16
1906
R/W
1
Numeric Error
Increments when a value received is
outside of the allowed range
0 to 65,535
INT16
1908
R/W
1
UART RX
Error
UART RX Error Counter. Command
Too Short.
0 to 65,535
INT16
1909
R/W
1
UART RX
Error
UART RX Error Counter. Command
Too Long.
0 to 65,535
INT16
1910
R/W
1
UART RX
Error
UART RX Error Counter. Command
received in invalid state
0 to 65,535
INT16