DM4380 – Installation Guide
Hardware DESCRIPTION
204.4336.00 - October/2019
19
3.10.1.2
PSU 125 DC
The figure below
shows the pin settings of the TERMINAL BLOCK connector to power the
switch
.
Figure 12 - DC Power Connector Pinout Settings
3.10.2
Power Cables
3.10.2.1
PSU 125 AC
The PSU 125 AC
includes a 3-meter power cord in the standard female IEC 320/C14 for
the NBR 14136 plug
.
3.10.2.2
PSU 125 DC
The PSU 125 DC
includes a 3.5 meter DC power cable in the PP 1 mm
2
gauge standard
with both ends open and the TERMINAL BLOCK standard male connector (normally
shipped screwed to the
PSU 125 DC)
for the installation of the cable
.
Follow the information below to install the cable to the Terminal Block connector
:
Step 1
Remove the TERMINAL BLOCK connector from the
PSU 125 DC
by
unscrewing the two side screws of the connector using a 1/8"
screwdriver (number 0) as shown below
: