background image

COLD START 

When the UPS is “Off” and there is no utility power, it is possible to power essential equipment connected to UPS for a 

short period of time. Make sure that only the most necessary equipment is connected to the UPS at this time. 

1.

 

Turn ON the UPS ON/OFF switch. 

2.

 

Complete what you need to do with the powered equipment, before the UPS battery is fully discharged. 

3.

 

Shut off the connected equipment. 

4.

 

Turn OFF the UPS ON/OFF switch. 

 

Technical specification                                                                 
 

Model 

400 

500/600  700  800 

1000  1200 

Power factor 

0.6 

Load type 

Personal computers and other PC peripheral devices 

Mains voltage range 

(140~290)±5Vac    or (70-145)±5Vac 

Mains frequency range 

40~70

±1Hz 

Output voltage range(Line mode) 

110Vac/120Vac/220Vac/230Vac±10%(Sine wave) 

Output frequency range(Line mode) 

Synch with mains input 

Output voltage range(battery mode) 

110Vac/120Vac/220Vac/230Vac±5%(Square wave) 

Output frequency range(battery mode) 

(50/60)±1Hz(frequency self-adapt system) 

Battery No-load protection 

Auto protection. The UPS  will automatically shut down after 2min 

no load detected 

Transfer time 

≤10ms 

Battery backup time* 

>6Min(half load) 

Battery protection 

Auto  protection.  The  UPS  will  automatically  shut  down  when 

battery voltage is low or high. 

Battery charging time 

8 hours to 90% 

Short circuit protection 

Auto  protection.  Output  shuts  off  and  the  buzzer  beeps 

continuously 

Overload protection 

110  %<  load  percentage≤  120%

buzzer  beeps

load 

percentage >120%

output shuts off

buzzer beeps continuously. 

Operating temperature 

0

~40

 

Storage temperature 

-15

~45

 

Relative humidity 

0%~90%(No condensation water) 

Noise 

≤35dB(1m from front panel) 

 

 

 

 

Size/L×W×H(mm) 

230*90

*145 

291*90

*145 

330*90*145  340x122x190 

Net weight Kgs 

 

4.5 

 

4.5  5 

5.2 

8.4 

9.4 

 
 
Note: The specification listed above is subject to change without notice. 

 

 

 

Содержание DT-UPS-500

Страница 1: ...For assistance contact our DataTronix Technicians at 610 429 1511 DT UPS SERIES DT UPS 500 DT UPS 1200 ...

Страница 2: ...the positive and negative electrodes of battery Otherwise it may cause electric shock or fire 6 Do not plunge or insert any objects into the air vents and other inlets 7 Do not store or use the device in the following environment l Where there is inflammable gas corrosive agents or heavy dust l Where the temperature is very high or low above 40 104 F or below 0 32 F or the humidity is very high mo...

Страница 3: ...ventilated area away from direct sources of heat Leave at least 100mm clearance all around the UPS to provide adequate ventilation Reference figure 1 Figure 1 Figure 2 The UPS is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment Please kindly note the following Reference figure 2 Avoid direct sunlight Avoid excessive heat Avoi...

Страница 4: ...HOULD BE TAKEN TO AVOID EXCESSIVE TEMPERATURE AROUND THE UPS WHICH COULD ALSO RESULT IN REDUCING SERVICE LIFE OF THE BATTERY TO ACHIEVE MAXIMUM SERVICE LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS SHOULD BE FOLLOWED The UPS battery charges whenever the UPS is connected to utility power is switched ON It typically requires twelve hours to charge fully Operating runtime is reduced until the battery ...

Страница 5: ...Turn ON this button to supply power to the UPS outlets To switch off power to the UPS outlets turn OFF the switch This switch is situated on the front panel of the UPS 2 AC NORMAL INDICATOR Green light continuous The UPS is supplying conditioned utility power to its outlets 3 BACKUP INDICATOR yellow light slow blinking The indicator starts slow blinking when utility power is outside acceptable lim...

Страница 6: ...ns input Output voltage range battery mode 110Vac 120Vac 220Vac 230Vac 5 Square wave Output frequency range battery mode 50 60 1Hz frequency self adapt system Battery No load protection Auto protection The UPS will automatically shut down after 2min no load detected Transfer time 10ms Battery backup time 6Min half load Battery protection Auto protection The UPS will automatically shut down when ba...

Страница 7: ...line Check input power at end of power cord and wall socket Otherwise call for service UPS suddenly turns to battery mode in spite of utility line present Rear panel input fuse open Reduce the load and replace fuse with same rating Input utility line too high or too low Check input line voltage Frequency out of range Check input frequency Single beep Normal UPS operation This is not a fault The UP...

Страница 8: ...on act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone service The warranties giv...

Отзывы: