background image

 MAINS
OUTLET

CONNECT EQUIPMENT TO UPS 

Now  connect  your lour load to  be protected (computer,  monitor etc.) to the  AC Output receptacles  at the rear  of the 

UPS (Reference the figure 4). 

   

 

 

                                                                                                                                                                                                                                                         

 

 

 

 

                          Figure 4                                                                                     

 

Enable the UPS by turning on the Power ON/OFF switch, which is situated on the front panel.                                 

 

 

The UPS is now ready to use. Switch on your equipment. 

 

BATTERY MAINTENANCE/BATTERY CHARGING

.   

AFTER SHIPMENT FROM THE FACTORY, THE BATTERY WILL NEED A FULL RECHARGING. OF AT LEAST 

12  HOURS.    IF  NOT  USED  FOR  A  LONG  PERIOD  OF  TIME,  THE  BATTERY  WILL  START 

SELF-DISCHARGING,  WHICH  MAY  RESULT  IN  A  SHORTER  SERVICE  LIFE  OF  THE  BATTERY  OR  MAY 

EVEN CAUSE DAMAGE TO IT DURING THE WARRANTY PERIOD. CARE SHOULD BE TAKEN TO AVOID 

EXCESSIVE TEMPERATURE AROUND THE UPS, WHICH COULD  ALSO  RESULT IN  REDUCING  SERVICE 

LIFE  OF  THE  BATTERY.  TO  ACHIEVE  MAXIMUM  SERVICE  LIFE  FROM  THE  BATTERY  THE  ABOVE 

INSTRUCTIONS SHOULD BE FOLLOWED. 

 

The UPS battery charges whenever the UPS is connected to utility power & is switched ON. It typically requires twelve 

hours to charge fully. Operating runtime is reduced until the battery is fully charged. 

 

TEST THE UPS 

To  test  UPS  on  battery  back-up,  disconnect  the  power  cord  and  observe  backup  Indicator  lights.  Your  PC  or  other 

connected equipment should continue to function normally until the UPS battery is drained of power. 

UPS Indicators and Controls 

                                                                                                 

 

 

 

 

 

 

 

 

 

                                        Figure 8 (LED display mode 1)                        Figure 9 (LED display mode 2) 

 
 
 
 
 

UPS

AC NORMAL(green light)

CHARGING(yellow light

FAULT(red light)

UPS

BACKUP(red light

)

BACKUP(yellow light

)

AC NORMAL(green light)

POWER

POWER

Содержание DT-UPS-500

Страница 1: ...For assistance contact our DataTronix Technicians at 610 429 1511 DT UPS SERIES DT UPS 500 DT UPS 1200 ...

Страница 2: ...the positive and negative electrodes of battery Otherwise it may cause electric shock or fire 6 Do not plunge or insert any objects into the air vents and other inlets 7 Do not store or use the device in the following environment l Where there is inflammable gas corrosive agents or heavy dust l Where the temperature is very high or low above 40 104 F or below 0 32 F or the humidity is very high mo...

Страница 3: ...ventilated area away from direct sources of heat Leave at least 100mm clearance all around the UPS to provide adequate ventilation Reference figure 1 Figure 1 Figure 2 The UPS is intended for indoor use only Although your UPS is very rugged its internal components are not sealed from the environment Please kindly note the following Reference figure 2 Avoid direct sunlight Avoid excessive heat Avoi...

Страница 4: ...HOULD BE TAKEN TO AVOID EXCESSIVE TEMPERATURE AROUND THE UPS WHICH COULD ALSO RESULT IN REDUCING SERVICE LIFE OF THE BATTERY TO ACHIEVE MAXIMUM SERVICE LIFE FROM THE BATTERY THE ABOVE INSTRUCTIONS SHOULD BE FOLLOWED The UPS battery charges whenever the UPS is connected to utility power is switched ON It typically requires twelve hours to charge fully Operating runtime is reduced until the battery ...

Страница 5: ...Turn ON this button to supply power to the UPS outlets To switch off power to the UPS outlets turn OFF the switch This switch is situated on the front panel of the UPS 2 AC NORMAL INDICATOR Green light continuous The UPS is supplying conditioned utility power to its outlets 3 BACKUP INDICATOR yellow light slow blinking The indicator starts slow blinking when utility power is outside acceptable lim...

Страница 6: ...ns input Output voltage range battery mode 110Vac 120Vac 220Vac 230Vac 5 Square wave Output frequency range battery mode 50 60 1Hz frequency self adapt system Battery No load protection Auto protection The UPS will automatically shut down after 2min no load detected Transfer time 10ms Battery backup time 6Min half load Battery protection Auto protection The UPS will automatically shut down when ba...

Страница 7: ...line Check input power at end of power cord and wall socket Otherwise call for service UPS suddenly turns to battery mode in spite of utility line present Rear panel input fuse open Reduce the load and replace fuse with same rating Input utility line too high or too low Check input line voltage Frequency out of range Check input frequency Single beep Normal UPS operation This is not a fault The UP...

Страница 8: ...on act of foreign enemies hostilities regardless of whether war is declared civil war rebellion revolution insurrection military or usurped power or confiscation terrorist activities nationalization government sanction blockage embargo labor dispute strike lockout or interruption or failure of electricity air conditioning or humidity control internet network or telephone service The warranties giv...