Data Harvest Group Ltd, 2014
Fastest logging speed (per channel): 50,000 samples per second [20 microsecond (µs) between
samples (50 kHz)]
Firmware upgradeable
Power specifications: 5 V at 500 mA or more
Rechargeable battery pack: Lithium-ion 3.7 V, 1300 mAh (for replacement Order No. 5007)
USB communication to PC V1.1 & V2.0 compatible
Operating range: 0 - 40
C and 0 to 95%RH (non-condensing).
Graphical LCD display (approx. 34 mm high x 68 mm wide - 75 mm diagonal).
Weight of V-Log (logger only): approx. 248 g (+ 7 g WiFi module)
External dimensions: approx. Height 44 mm max x Width 144 mm x Depth 102 mm.
WiFi specifications
V-Log WiFi is a wireless enabled data logger. It is classed as a mobile device and has a usable
transmission range of 0.2 m to 10 m in open air.
V-Log WiFi loggers produced prior to April 2016 are compatible with IEEE 802.11
b
.
V-Log WiFi loggers produced after April 2016 are compatible with IEEE 802.11
n
.
Supports WPA-Personal (TKIP) and WPA2-Personal (AES) Security (802.11i)*
Frequency Range: 2412-2462 MHz
Channels supported: 1 to 11
*V-Log WiFi will automatically detect and use the required security protocol.
Hereby, Data Harvest Group Ltd., declares that V-Log WiFi is in compliance with the essential
requirements and other relevant provisions of Directive 2014/53/EU.
A full copy of the Declaration of Conformity can be obtained by writing to the following address:
Data Harvest Group Ltd., 1 Eden Court, Leighton Buzzard, Bedfordshire, LU7 4FY, UK.
Bluetooth specifications
Bluetooth 4.2 low energy radio, single mode compliant
Transmit (TX) power: 0 dBm
Receiver (RX) sensitivity: - 90 dBm
Usable transmission range: up to 10 m in open air
Frequency Range: 2.402 to 2.480 GHz operation
Care & Maintenance
Clean with a damp cloth, do not immerse in water or detergent. V-Log is
not
waterproof.
Do not subject to extreme heat or cold or leave in a location where it will get wet.
Do not place your logger in an environment in which high humidity levels are possible as this may
result in damage or malfunction
If
V-Log has been left in the cold, let it warm to near room temperature before waking it from sleep.
Do not expose to direct sunlight for extended periods of time.
Do not expose to temperatures great
er than 60˚ C, e.g. near a heater or inside a car in hot weather.
Do not store V-Log with its battery fully discharged. Ideally V-log
should be stored at least
40% or
more
state-of-charge. See page 20.