AMPLIFIER
1
) SIGNAL INPUT :
XLR type input signal connectors. As the LOOP THRU connector, they are balanced with the following
pin assignments:
1=GND (Ground).
2=(+) Non inverted input.
3=(-) Inverted input.
2
) LOOP THRU :
XLR type output signal connector for connecting several units together and sending them all the same
input signal.
3
) SIGNAL / LIMIT :
Two color LED which indicates that there is signal presence if it shines green or indicates amplifier
saturation and the amplifier limiter is activated, if it shines red.
4
) IDENTIFY / COMMS :
Orange LED that shines flashing when we push IDENTIFY (to identify the unit) or blink faster if there is
TM
communication with
DASnet
.
5
) ON / PROTECT :
Two color LED indicates that the unit is ON if it shines green and protection if it shines red.
6
) LPF PRESET :
This push button allows the “LOW PASS FILTER” selection. The LED shining indicates the selected value.
7
) CARDIOID PRESET :
This push button allows the “CARDIOID PRESET” selection. The LED shining indicates the selected
value: OFF, 2 units and 3 units.
8
)
IN
/OUT :
TM
Neutrik EtherCon connectors for audio+data input/output with
DASnet
. With the output connector we
can interconnect several units.
9
) Zone for user notes.
10
) AC INPUT SELECT :
This switch actives, or not, the mains connector at the front side of the enclosure. When we use a
cardioid configuration, we should connect the mains at the front side of the turned enclosure for wires'
grouping.
11
) AC INPUT :
Neutrik PowerCon TRUE1 mains connector.
Only use this equipment with an appropriate mains
cord.
12
) AC OUTPUT :
Neutrik PowerCon TRUE1 mains connector for connecting several units of
LX-118A
(please, see the
maximum value on the label).
13
) ID DASNET :
TM
Label with identification number for
DASnet
.
9
View of the amplifier
LOW PASS FILTER
UNIT NAME
STAGE / VENUE
NOTES
115/230 V~ 50/60Hz 420W
AC INPUT
MAX. 7@230V / 3@115V UNITS LX-118A
AC OUTPUT
ID DASNET
AC INPUT SELECT
I
REAR FRONT
13
9
11
10
12
D.A.S. AUDIO S.A. (Valencia) MADE IN SPAIN
SIGNAL INPUT
IDENTIFY/COMMS
LOOP THRU
ON/PROTECT
SIGNAL/
LIMIT
CAUTION
DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE
RISK OF ELECTRIC SHOCK
DO NOT OPEN
IN
OUT
90Hz
80Hz
70Hz
60Hz
L
O
W P
A
S
S F
IL
T
E
R
LPF
PRESET
CARDIOID
PRESET
OFF
F
R
F
F
R
LX-118A
www.dasaudio.com
2
1
6
8
5
4
3
7
Note:
To “reset” without using DASnet, press and hold the “CARDIOID PRESET” button, while
turning the PowerCON and turn on the power.
Manual del Usuario
/ LX-118A /
User’s Manual