background image

CONTENTS

6

7

12 

aero 20A

 + 4 

LX-118A

 (rigging)

aero 20A

 + 4 

LX-118A

 (stacking)

INTRODUCTION

LINE DRAWINGS

3

4

5

8

8

18

19

9 to 13

14 to 17

AMPLIFIER

SPECIFICATIONS

RIGGING SYSTEM

APPENDIX I

APPENDIX II

Description

ON / OFF

Overload Indicators

Overheating

Equalisation

Low mains voltage

Current consumption

CONFIGURATIONS

Troubleshooting

Line conections: unbalanced and balanced

DASnet cables

SAFETY PRECAUTIONS

WARRANTY

DECLARATION OF CONFORMITY

Manual del Usuario

 / LX-118

A

 / 

User’s Manual

Содержание LX-118A

Страница 1: ...tilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ...

Страница 2: ...FIER SPECIFICATIONS RIGGING SYSTEM APPENDIX I APPENDIX II Description ON OFF Overload Indicators Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS Troubleshooting Line conections unbalanced and balanced DASnet cables SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario LX 118A User s Manual ...

Страница 3: ...alimentación indicada en la etiqueta trasera según IEC 60065 2001 Working temperature ranges from 15ºC to 42ºC with a relative humidity of 95 with 10 of the rated main voltage value indicated on the rear label according to IEC 60065 2001 No instale el aparato cerca de ninguna fuente de calor como radiadores estufas u otros aparatos que produzcan calor Debe instalarse siempre sin bloquear la libre ...

Страница 4: ...tía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra GARANTÍA All D A S products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised s...

Страница 5: ... RAEE WEEE 2012 19 UE 5 Y es conforme a las siguientes Normas Armonizadas Europeas In accordance with Harmonized European Norms l EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 Audio video and similar electronic apparatus Safety requirements l EN 55103 1 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for profess...

Страница 6: ...ation unit incorporates monitoring and remote control via DASnet the audio management application for D A S audio S A enclosures and processors You can choose various types of lowpass filters by DASnet or by the controls on the rear panel of the amplifier It also incorporates two type settings presets for cardioid for 2 and 3 units As for the enclosure it is built using birch plywood with reinforc...

Страница 7: ...H 2 3 1 PUSH Dasnet Rack 26 eCP_20 eCP_20 eCP_20 eCP_20 Rear View eCP_20 R L L1 L2 L3 I o FI40 30mA 4pol FI Schalter 6 x MCB 16A C 1pol 1 x RCD 40A 30mA 4pol 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 2 3 1 PUSH 2 3 1 PUSH 2 3 1 PUSH Dasnet Rack 26 eCP_20 eCP_20 eCP_20 eCP_20 Rear View eCP_20 Example for rigging Example for stacking 12 x Aero 20A 4 x ...

Страница 8: ...nced Line 20 kohms Line 6 2 V 18 dBu 33 Hz 120 Hz 135 dB 1 x 18LXN Birch Plywood Black ISO flex Paint GM 18LX Audio INPUT Female XLR Audio LOOP THRU Male XLR Audio Data INPUT EtherCon Audio Data LOOP THRU EtherCon AC INPUT PowerCon TRUE1 AC OUTPUT Powercon TRUE1 6A 115 V 50 Hz 60 Hz 3A 230 V 50 Hz 60 Hz 50 x 65 x 81 cm 19 7 x 25 6 x 31 9 in 47 kg 104 lb AX LX118 Rigging System Pick up AX aero20 AX...

Страница 9: ... With the output connector we can interconnect several units 9 Zone for user notes 10 AC INPUT SELECT This switch actives or not the mains connector at the front side of the enclosure When we use a cardioid configuration we should connect the mains at the front side of the turned enclosure for wires grouping 11 AC INPUT Neutrik PowerCon TRUE1 mains connector Only use this equipment with an appropr...

Страница 10: ...able the mains connector at the front side of the turned enclosure enclosure 2 When boxes are flown in cardioid configuration the turned units must be fed by the front for wires grouping as shown in the figure Rain protector of LX 118A 10 AC INPUT SELECT Rear View Select FRONT with the switch to enable the mains connector at the front side of the turned enclosure 2 eCP_20 LOW PASS FILTER UNIT NAME...

Страница 11: ...tion to produce quality sound Avoid high levels of gain on the equalisers Gain values above 3 dB on a console s EQ are not recommended Overload indicator This device has a SIGNAL LIMIT indicator The red light indicates the signal is excessive The indicator should not be lit continuously This distorts the signal quickly fatiguing your ears and may damage the speakers Low mains voltage If mains volt...

Страница 12: ...esponse Current consumption AC input 230 Vrms The most common use will be combined with the satellite system The use of an external delay to control and adjust the phase of the subs is recommended with a digital processor for example The SUB units are linked with the THRU option setting The OUTPUT and LOOP THRU connectors are output XLR type connectors and are useful for daisy chaining the same si...

Страница 13: ...e connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 Faulty AC cable 3 Internal fuse blown SOLUTION 1 Check that the mixer or sound source is sending signal to the UNIT 2 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if defective 1 If using a mixer use the balanced output if available Use a professional mixer...

Страница 14: ... an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 Kg 7 1 safety factor When flying a system the working load must be lower than the resistance of each individual flying point in the enclosure as well as each box Hanging hardware should be regularly inspected and suspect units replaced if in doubt This is importa...

Страница 15: ...des We will show the cardioid configurations separately in order to appreciate the diferences and similarities OMNIDIRECTIONAL CARDIOID 2 1 2 1 Join cabinets Join cabinets Turn guide Turn guide Turn guide Turn guide Insert Pin Insert Pin Insert Pin Insert Pin Front side of the enclosure Front side of the enclosure Front side of the enclosure Front side of the enclosure Rear side of the enclosure R...

Страница 16: ...angle between the first Aero 20A and the last LX 118A is 0º The maximum angle between the first Aero 20A and the last LX 118A is 3 5º PL 118S The PL 118S platform can help transport up to 2 units of LX 118A Handle with care to avoid a tip over during transport As always when we handle heavy loads we should wear appropriate clothing and protective elements such as gloves safety shoes etc PL 118S WL...

Страница 17: ... the steps will be 1 Release the front guides in the LX 118A 2 Put a unit of Aero 20A over the LX 118A fitting the guides at the front and insert the safety pins 3 Ensure that the Aero 20A has unlocked the angulation UNLOCK 4 Lift the back of the Aero 20A and put the accessories on both sides of the box as shown in the figures below 5 Insert the safety pins in the holes corresponding to the desire...

Страница 18: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Страница 19: ...s are named eCP_xx xx refers to cable length and the standard values are 3m or 20m The links between cabinets aero40A Convert15A LX 218CAnet which are STP CAT7 cables Cable code eC_09 Power Links between cabinets Cable code Plink1_09 Links for RoadNet series Power STP CAT7 eCPk_1 eCPk_5 The main feed cable eCP_xx has the following structure AL Shield 2 2 ecP_xx Power cable 3x2 5mm CAT7 4x 2 x 0 14...

Страница 20: ...C 6900 NW 52th Street Miami FL 33166 U S A TOLL FREE 1 888 DAS 4 USA D A S AUDIO ASIA PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 D A S AUDIO S A C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 ...

Отзывы: