STAR/DELTA VOLTAGE CONNECTION 

 

Warning! Danger of death due to electric shock. 
Before starting the assembly operations, exclude the voltage from the conductors and check that 
they are equal to zero. 
The commutability of the motor voltage makes it possible to use the gearmotor on both a 3 x 400 V 
and 3 x 230 V power grid. 
The motor is wired in the factory with star connection for a 3 x 400 V power grid. 
For connection to a 230 V power grid, switch the motor onto a delta connection. 
To commute the voltage onto the motor, wire the ends of the windings as illustrated in fig. 13-16. 
When fixing the motor cables, pay attention that the cables are long enough to consent solid fixing, 
to create a connection able to remain secure over time. 
Pull the conductors to check if the connection is secure. 
When switching over the motor for connection to a 3 x 230 V power grid, it is necessary to also adjust 
the gearmotor. 

 

3x 230V 

 

 

 

 

 

3x 400V (default) 

 

 

 

 

 

 
 

 

ANNUAL CHECK 

 

BGR 232 directive “Windows, doors and main doors with mechanical

 

operation” is applied. It can be 

obtained from the National Insurance Institute for Industrial Accidents of your trade association or 
from us on request. 
Maintenance interventions on windows, doors and main doors with mechanical operation must be 
performed only by personnel authorized by the company, having the necessary experience and 
skills (BGR 232). 

 
 

Содержание 008641

Страница 1: ...BLE OF CONTENT General information 2 Safety standards 2 Installation rules 2 General danger warnings and preventive safety 4 Assembly instruction Fixing the mechanism 4 Emergency manual releases 5 Limit switch setting 6 Star Delta voltage connection 7 Annual check 7 Technical specifications 8 Technical dimensions 9 Declaration of conformity 9 ...

Страница 2: ... and EN 13241 1 in particular which enable conformity of the automated functionality to be de cleared In the light of the above all work involving installation connection testing and maintenance of the product must be carried out exclusively by qualified and competent technicians INSTALLATION RULES Before commencing the installation check if the product is suitable for the de sired type of use If ...

Страница 3: ...al capacities or who lack experience or knowledge unless supervised or trained in the use of the product by a person responsible for their safety Any children near the automation system must be kept under supervision to ensure that they do not play with it Do not allow children to play with the fixed control devices Keep remote control devices out of the reach of children The instructions shall co...

Страница 4: ...l Insurance Institute for Industrial Accidents BGR 232 The static overturning moment is the maximum load allowed for the mechanism at the time the spring breaks The Mstat static overturning moment is calculated with the following formula Mstat Nm Wing weight N cable winder drum radius m Considering that two balancing springs can yield at the same time the Commission of experts about building devic...

Страница 5: ...lose the door turning the handle The control voltage is reset and the door can again be activated electrically by removing the handle Manual chain operated emergency release fig 4 and 9 Movement to the right or left activates a microswitch that will cut out the voltage going to the reduction unit afterwards the main door can be opened or closed by pulling the chain After releasing the chain the vo...

Страница 6: ...d by manually opening and closing the door with identical activation force in both directions The Evotronix magnetic limit switch is a positioning switch with absolute value for rolling shutters doors and main doors The assessment or setting of the final positions is carried out with gearmotors for doors During assembly simply insert the six pole plug Mechanical settings and positionings are not n...

Страница 7: ...to the motor wire the ends of the windings as illustrated in fig 13 16 When fixing the motor cables pay attention that the cables are long enough to consent solid fixing to create a connection able to remain secure over time Pull the conductors to check if the connection is secure When switching over the motor for connection to a 3 x 230 V power grid it is necessary to also adjust the gearmotor 3x...

Страница 8: ...g the annual check perfect brake operation is to be ascertained In the case of heavy wear of the brake pads it is necessary to replace the complete brake Before replacement disconnect the cables connected to the electric card TECHNICAL SPECIFICATIONS NOTE all the technical characteristics indicated refer to a temperature falling between 5 C and 40 C DAS reserves the right to change all the modific...

Страница 9: ...Manual Sectional Door Drive 9 DAS Deutsche Antriebs und Steuerungstechnik GmbH Otto Hahn Str 3 48301 Nottuln Germany info das automation com TECHNICAL DIMENSIONS ...

Отзывы: