background image

Manual 

Sectional Door Drive 
 

 

DAS 

 Deutsche Antriebs und Steuerungstechnik GmbH  

Otto-Hahn-Str. 3 

 48301 Nottuln 

 Germany  

[email protected] 

 
 
 

GENERAL INFORMATION 

 

The gearmotors to which this instruction booklet refers are designed for operating sectional doors 
balanced with springs or weights. If these products are to be used for different applications, it is 
recommended to first discuss them with the Manufacturer. 
The declaration loses its validity if the gearmotor is modified (e.g. wiring reversal). 

 
 

SAFETY STANDARDS 

 

• This manual contains important instructions

 and warnings regarding safety. Incorrect installation 

may cause serious injury. Before commencing work, all sections of the manual 
must be read carefully. If in any doubt, suspend installation and call the DAS Support Service for 
clarification. 
 

• This man

ual contains important instructions. Keep it for future maintenance work and disposal of 

the product. 
 

• Under the latest European legislation, automatic door and gate installations must be compliant 

with the standards specified in Directive 2006/42/EC (formerly 98/37/EC) (the Machinery Directive) 
and the standards EN 12445, EN 12453, EN 12635 and EN 13241-1 in particular, which enable 
conformity of the automated functionality to be de cleared. In the light of the above, all work 
involving installation, connection, testing and maintenance of the product must be carried out 
exclusively by qualified and competent technicians! 

 
 

INSTALLATION RULES 

 

• Before commencing the installation, check if the product is suitable for the de sired type of u

se. If it 

is not suitable, do not continue with the installation. 
 

• The contents of this manual refer to a standard system.

 

 

• All installation and maintenance work must be carried out

 with the control unit disconnected from 

the electricity supply. If the power disconnection device cannot be seen from where the control unit 
is positioned, then before starting work a notice must be attached to the disconnection device 

bearing the words “CAUTION! MAINTENANCE IN PROGRESS”.

 

 

• The Control unit must be connecte

d to an electricity supply line equipped with protective earthing. 

 

• Handle the product with care during installation, taking care to

 avoid crushing, denting or dropping 

it, or contact with liquids of any kind. Keep the product away from sources of heat and naked flames. 
Failure to observe the above can damage the product and increase the risk of danger or malfunction. 
Should this occur, suspend installation work immediately and contact the DAS Support Service. 

Содержание 008641

Страница 1: ...BLE OF CONTENT General information 2 Safety standards 2 Installation rules 2 General danger warnings and preventive safety 4 Assembly instruction Fixing the mechanism 4 Emergency manual releases 5 Limit switch setting 6 Star Delta voltage connection 7 Annual check 7 Technical specifications 8 Technical dimensions 9 Declaration of conformity 9 ...

Страница 2: ... and EN 13241 1 in particular which enable conformity of the automated functionality to be de cleared In the light of the above all work involving installation connection testing and maintenance of the product must be carried out exclusively by qualified and competent technicians INSTALLATION RULES Before commencing the installation check if the product is suitable for the de sired type of use If ...

Страница 3: ...al capacities or who lack experience or knowledge unless supervised or trained in the use of the product by a person responsible for their safety Any children near the automation system must be kept under supervision to ensure that they do not play with it Do not allow children to play with the fixed control devices Keep remote control devices out of the reach of children The instructions shall co...

Страница 4: ...l Insurance Institute for Industrial Accidents BGR 232 The static overturning moment is the maximum load allowed for the mechanism at the time the spring breaks The Mstat static overturning moment is calculated with the following formula Mstat Nm Wing weight N cable winder drum radius m Considering that two balancing springs can yield at the same time the Commission of experts about building devic...

Страница 5: ...lose the door turning the handle The control voltage is reset and the door can again be activated electrically by removing the handle Manual chain operated emergency release fig 4 and 9 Movement to the right or left activates a microswitch that will cut out the voltage going to the reduction unit afterwards the main door can be opened or closed by pulling the chain After releasing the chain the vo...

Страница 6: ...d by manually opening and closing the door with identical activation force in both directions The Evotronix magnetic limit switch is a positioning switch with absolute value for rolling shutters doors and main doors The assessment or setting of the final positions is carried out with gearmotors for doors During assembly simply insert the six pole plug Mechanical settings and positionings are not n...

Страница 7: ...to the motor wire the ends of the windings as illustrated in fig 13 16 When fixing the motor cables pay attention that the cables are long enough to consent solid fixing to create a connection able to remain secure over time Pull the conductors to check if the connection is secure When switching over the motor for connection to a 3 x 230 V power grid it is necessary to also adjust the gearmotor 3x...

Страница 8: ...g the annual check perfect brake operation is to be ascertained In the case of heavy wear of the brake pads it is necessary to replace the complete brake Before replacement disconnect the cables connected to the electric card TECHNICAL SPECIFICATIONS NOTE all the technical characteristics indicated refer to a temperature falling between 5 C and 40 C DAS reserves the right to change all the modific...

Страница 9: ...Manual Sectional Door Drive 9 DAS Deutsche Antriebs und Steuerungstechnik GmbH Otto Hahn Str 3 48301 Nottuln Germany info das automation com TECHNICAL DIMENSIONS ...

Отзывы: