TRANSDUCER PULSES
50 or 60 HERTZ
x
M
÷
S
COUNT and
DISPLAY
input
display and reset
command
THEORY OF OPERATION
The input pulses from the transducer are counted and then multiplied by “M” (input count multiplier). In order to have a steady
display, the display is updated every .0167 seconds x “S” (divide by count time) for the DM4004. The multiplier “M” is a phase lock
loop, while the divide by, “S”, is a simple timer set via binary switches. Thus, we have field programmable scaling. The unit provides
+5 VDC for the transducer.
OPTION DESCRIPTION
240VAC input (50 or 60 Hertz) ............................................................................................................ -5 OPTION
CUSTOMER
SUPPLIED
MOUNTING SCREWS
PANEL MOUNTING GASKET
(NARROWER SIDE OF GASKET GOES
ON TOP, WITH THE ADHESIVE SIDE OF
GASKET FACING THE CUSTOMER
MOUNTING PANEL)
CUSTOMER
MOUNTING PANEL
(HOLE CUT-OUT FOR CONTROL
HOUSING APPROXIMATELY
3.675" WIDE BY 1.770" HIGH)
DM4000 SERIES
CONTROL
DM4000 SERIES
FACEPLATE
ASSEMBLY
2
CUT-OUT & MOUNTING DIMENSIONS
STEP 1: Remove two screws securing red lens.
STEP 2: Mount the DM4000 series meter into the panel cut-out. Note diagram for cut-out dimensions shown below. Allowance
for easy insertion of meter into panel must be made.
STEP 3: Secure meter into panel. The two mounting holes have a diameter of .141 inch. Use #6 hardware to fasten to panel.
4.000"
.885"
1.770" x 3.675" cut-out
weight: 12.5 oz.
CL
LENS & HOUSING DIMENSIONS
PANEL CUT-OUT DIMENSIONS
4.420"
2.250"
0.25" lens
depth
Programmable Tachometer
3.620"
1.655"
4.125"
housing
depth
MOUNTING INSTRUCTIONS
Note:
Use caution to prevent
pinching the ribbon cable
between red lens and heatsink
metal during reassembly.