WARRANTY

Dart Controls, Inc. (DCI) warrants its products to be free from defects in material and workmanship. The exclusive remedy for this
warranty is DCI factory replacement of any part or parts of such product which shall within 12 months after delivery to the purchaser
be returned to DCI factory with all transportation charges prepaid and which DCI determines to its satisfaction to be defective. This
warranty shall not extend to defects in assembly by other than DCI or to any article which has been repaired or altered by other
than DCI or to any article which DCI determines has been subjected to improper use. DCI assumes no responsibility for the design
characteristics of any unit or its operation in any circuit or assembly. This warranty is in lieu of all other warranties, express or implied;
all other liabilities or obligations on the part of DCI, including consequential damages, are hereby expressly excluded.

NOTE: Carefully check the control for shipping damage. Report any damage to the carrier immediately. Do not attempt to operate
the drive if visible damage is evident to either the circuit or to the electronic components.

All information contained in this manual is intended to be correct, however information and data in this manual are subject to change
without notice. DCI makes no warranty of any kind with regard to this information or data. Further, DCI is not responsible for any
omissions or errors or consequential damage caused by the user of the product. DCI reserves the right to make manufacturing
changes which may not be included in this manual.

WARNING

Improper installation or operation of this control may cause injury to personnel or control failure. The control must be
installed in accordance with local, state, and national safety codes.
 Make certain that the power supply is disconnected
before attempting to service or remove any components!!! If the power disconnect point is out of sight, lock it in
disconnected position and tag to prevent unexpected application of power. Only a qualified electrician or service
personnel should perform any electrical troubleshooting or maintenance. At no time should circuit continuity be checked
by shorting terminals with a screwdriver or other metal device.

INTRODUCTION

The Dart DM4000 Series is available in two basic field programmable models:

DM4004 - RATE BASED DISPLAY - Displays the rate of shaft rotation in RPM, GPM, FPM, etc.
DM4005 - PROCESS TIME DISPLAY - Displays the time of the process, based upon shaft rotation.

STANDARD FEATURES

The DM4000 Series features a sturdy 1/8DIN aluminum housing with gasketed faceplate kit for panel mount. It will accept a variety
of signal inputs, and is field programmable via dip switches. The compact series provides a five position barrier terminal strip for
ease of connection and a large 1/2" four digit LED display, including customer selectable decimal points. Self-contained power
supply for transducer of +5VDC and 75mA output.

Works in conjunction with a transducer

The Dart PU-E pick-up is recommended for use with the DM series, however the DM4000 will accept inputs from a variety of
transducer types. Included are hall-effect, photo-electric, magnetic, TTL, or any +5 to 24VDC device. See “Pick-up Selection Chart”
on page 3.

Operates on either a 50 or 60 Hertz signal

The DM4000 Series comes standard for a 60 Hertz signal, but can be easily changed to 50 Hertz by using the “Field Programming
Formula” on page 4. This program simply changes the time base settings, substituting 3000 for 3600 in the Field Programming
Formula. This compensates for the change in the clock frequency from 60 Hertz to 50 Hertz.

TABLE OF CONTENTS

WARRANTY ...............................................................................................................................................................................  1

INTRODUCTION & STANDARD FEATURES ...........................................................................................................................  1

THEORY OF OPERATION .........................................................................................................................................................  2

OPTION DESCRIPTION .............................................................................................................................................................  2

CUT-OUT & MOUNTING DIMENSIONS ....................................................................................................................................  2

MOUNTING INSTRUCTIONS ....................................................................................................................................................  2

PU-E SERIES PICK-UP INSTALLATION ..................................................................................................................................  3

DM4000 SERIES HOOK-UP & WIRING ....................................................................................................................................  3

FIELD PROGRAMMING THE DM4000 SERIES ....................................................................................................................  4-5

DECIMAL POINT SELECTION ..................................................................................................................................................  5

COMMONLY ASKED QUESTIONS ........................................................................................................................................  5-6

SPECIFICATIONS ......................................................................................................................................................................  6

PRODUCT LINE ...................................................................................................................................................  BACK COVER

1

Содержание DM4000 Series

Страница 1: ... CONTROL SERIES LTDM4 IM DM4 0501 P O Box 10 5000 W 106th Street Zionsville Indiana 46077 Phone 317 873 5211 Fax 317 873 1105 www dartcontrols com Instruction Manual Low Voltage DC Brushless Control CONTROLS ...

Страница 2: ...wer disconnect point is out of sight lock it in disconnected position and tag to prevent unexpected application of power Only a qualified electrician or service personnel should perform any electrical troubleshooting or maintenance At no time should circuit continuity be checked by shorting terminals with a screwdriver or other metal device INTRODUCTION The Dart DM4000 Series is available in two b...

Страница 3: ... SIDE OF GASKET FACING THE CUSTOMER MOUNTING PANEL CUSTOMER MOUNTING PANEL HOLE CUT OUT FOR CONTROL HOUSING APPROXIMATELY 3 675 WIDE BY 1 770 HIGH DM4000 SERIES CONTROL DM4000 SERIES FACEPLATE ASSEMBLY 2 CUT OUT MOUNTING DIMENSIONS STEP 1 Remove two screws securing red lens STEP 2 Mount the DM4000 series meter into the panel cut out Note diagram for cut out dimensions shown below Allowance for eas...

Страница 4: ...g or noisy environments a shielded cable is recommended Connect the shield to the common terminal on the ASP10 leaving the shield on the PU E end floating No other mounting screws are necessary as the cord will keep the unit from rotating The PU E gives a high signal when the north pole of the magnetic disk crosses the hall effect The signal is switched low when the south pole crosses the same res...

Страница 5: ...LD PROGRAMMING FORMULA MULTIPLIER TRIMPOT DISPLAY PANEL TIMER SWITCHES DM4000 FRONT VIEW WITHOUT LENS Example Find R We want the meter to display 15 feet per minute at a shaft speed of 1000 RPM Therefore R 15 1000 0 015 Example Use Programming Formula for the DM4004 A motor drives an auger which moves material and we want displayed lbs hr of material moved We know that at 990 RPM we move 435 lbs o...

Страница 6: ... 226 then S8 128 S7 64 S6 32 S2 2 226 STEP 6 Set the Multiplier trimpot using the M value determined in STEPS 3 4 and 5 DECIMAL POINT SELECTION All decimal points are illuminated and are covered with black adhesive backed dots If a decimal point is needed remove dot to illuminate the desired decimal point COMMONLY ASKED QUESTIONS Q Can the DM4000 Series be used above 9 999 RPM A Yes there will be ...

Страница 7: ...etween inputs A Yes On the PU E pick up switch the SIG wire and leave the COM and V connected to each pick up do not exceed nine PU E pick ups per DM unit Q Can I tie the DM4000 Series to a computer A No there are no computer outputs available from the DM4000 Series Q What is the update time A This varies with the programming of the S value setting which ranges from 0167 through 4 25 seconds The D...