7.3.

 

Insert the individual wires into the slots inside the cap of the end cap. 

7.4.

 

Screw  the  hex  nut  onto  the  cap.  Use  a  wrench  to  ensure  the  hex  nut  is 
screwed in all the way to the base of the cap.   

 

WARNING

 

 

Ensure  the  AC  trunk  cable  and  end  cap  do  not  touch  the  roof  by  using  cable 
clips  or  tie  wraps  to  attach  the  trunk  cable  to  the  PV  racking.  Ensure  that  all 
cabling is located underneath the PV module. 

 

Step 8: Connect the AC Junction Box 

Connect the AC trunk cable to the AC junction box using the appropriate gland or 
strain relief fitting. The AC trunk cable requires a strain relief connector with an 
opening of 1.6 cm (0.6 in) in diameter. 
The wires in the AC trunk cable are identified by color: L1 is sheathed in Black, L2 
is sheathed in Red, Neutral is sheathed in White and Ground is sheathed in Green. 
Note the Neutral/White wire is unused. 
 

 

WARNING 

Although the AC trunk cable includes a grounding wire, the continuous grounding 
conductor or grounding washers is still required. 

 

Step 9: Connect the PV Modules 

Mount the PV modules above the micro inverters, and then connect each micro 
inverter to a PV module. (The micro inverter and PV module’s DC cables have two 
connectors.  Connect  the  micro  inverter  positive  connector  to  the  PV  module 
negative connector, and vice versa.) 
 

 

CAUTION 

Micro inverters and PV modules are installed using a one to one ratio. 

POST-INSTALLATION 

WARNING 

 

Service/changes  to  your  electrical  system  should  be  carried  out  only  by 
qualified electricians. Do not attempt to repair this product; it does not contain 
user-serviceable parts. Repairs and internal servicing should only be performed 
by authorized service personnel. 

Commissioning and Operating 

Step1.

 

Turn  on  the  AC  disconnect  or  the  circuit  breaker  for  each  micro  inverter 
AC branch circuit. 

Step2.

 

Turn  on  the  main  utility-grid  AC  circuit  breaker.  Your  system  will  start 
producing power after five minutes. 

Step3.

 

Register PV system on Darfon Solar Portal. (Monitoring System - Optional). 
Depending on the strength of the signal, it can take up to 2 hours before 
the monitoring system detects all the micro inverters in the PV system. 

 

LED 

LED Status 

Mode 

Possible Reason 

Power Status LED

 

 

Solid Green 

Generate  Operating normally 



 

Flashing Green  Prepare 

Initialization, restart 



 

Flashing Red 

Protect 

OVP, UVP, OFP, UFP, ISL, OPP 

 

Solid Red 

Danger 

GFDI activated 

 

Off (at daytime)  Fail 

Dead or no PV input 

COMM Status LED

 

 

Solid Blue 

Ready 

Operating normally 



 

Flashing Blue 

Data 

Communicating data 

 

Off (at daytime)  Fail 

Dead or no PV input 

GFDI Fault 

GFDI  fault  is  defined  as  an  unintentional,  electrically  conducting  connection 
between  an  ungrounded  conductor  of  an  electrical  circuit  and  the  normally 
non-current-carrying conductors, metallic enclosures, metallic raceways, metallic 
equipment  or  earth.  When  a  Ground  fault  occurs,  the  GFDI  will  trigger  the  LED  
light  to  show  continuous  Red,  and  the  micro  inverter  will  automatically 
disconnect all conductors as a safety precaution. 
 
If  the  GFDI  has  detected  a  ground  fault,  please  contact  with  the  installer  and 
follow  the  Operation  Manual  to  clear  this  condition.  Or  you  can  contact  Darfon 
customer support at 

[email protected]

Содержание G320

Страница 1: ...G320 MI CRO I NVERTER U S E R M A N U A L...

Страница 2: ...4 PRE INSTALLATION 5 THE MICRO INVERTER 5 PV SYSTEM LAYOUT 5 PARTS AND TOOLS 5 COMPATIBILITY AND CAPACITY 6 AC TRUNK CABLE 6 GROUNDING OPTIONS 6 MICRO INVERTER LAYOUT 7 SURGE PROTECTION 7 INSTALLING T...

Страница 3: ...urns use caution when working with micro inverters Do not disconnect the DC power source from the micro inverter without first disconnecting the AC power source Both AC and DC power sources must be di...

Страница 4: ...G are bound together or DS73RS 120 where N and G are not bound together JDA D1 80 xxx VG R series http www jdauspice com uploads 2011 01 10 SPD_catalogue pdf FCC Compliance This equipment has been tes...

Страница 5: ...to tap power from the center of the circuit so 2 segments of 9 and 10 modules total 19 for each circuit This maximizes the communication signal strength to the PLC box The use of a RS485 specific cabl...

Страница 6: ...or four pins four wires Currently the four pin AC trunk cable is used Pin Wire Color Wire Usage 1 Black L1 2 Red L2 3 Green Ground 4 White Neutral Grounding Options Option 1 Integrated Grounding Inte...

Страница 7: ...eeled off the micro inverter and adhered to the installation map template where the actual position on the roof would correspond to the same panel on the layout drawing Note Tracking micro inverter lo...

Страница 8: ...icro inverter will be installed Then secure the cable on either side of the rack using cable clips or tie wraps Note the maximum pitch distance is 1050mm when modules are in portrait mode and 1700mm w...

Страница 9: ...fully inserted WARNING Correct AC grounding and short circuit protection must be provided to ensure operational safety 6 2 Repeat for all 1T AC trunk cable in the AC branch circuit 6 3 After connect...

Страница 10: ...ION WARNING Service changes to your electrical system should be carried out only by qualified electricians Do not attempt to repair this product it does not contain user serviceable parts Repairs and...

Страница 11: ...od of time If the removed micro inverter will not be replaced with another micro inverter immediately connect a sealing cap to the T branch connector TROUBLESHOOTING Troubleshooting the Micro Inverter...

Страница 12: ...contact the Technical Support at support darfon com TECHNICAL SPECIFICATIONS Micro Inverter G320 INPUT FROM PV DC Number of Panels per Inverter One Nominal Power STC of Each Panel 320 W Recommended ST...

Страница 13: ...and keep track of the micro inverters placement by serial number Peel off and use secondary serial number label on the micro inverter Installer Array Name Site Address Azimuth Date ______________ She...

Страница 14: ...1 4 NOTES Manufactured by Darfon Electronics Corp 167 Shan ying Road Gueishan Taoyuan 333 Taiwan R O C Tel 886 3 2508800 USA Office Darfon America Corp 103A Pioneer Way Mountain View CA 94041 Tel 1 65...

Отзывы: