IMPORTANT INFORMATION

The DL-300 data logger is the hardware that connects Darfon hybrid inverters to the Darfon cloud monitoring system. Please read all 
instructions before installing this data logger. And, store this installation manual where it can be accessed easily.

What You Need Before You Begin

 

Internet service

 

A computer with WiFi

FCC Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by one or more of the 
following measures:

 

Reorient or relocate the receiving antenna.

 

Increase the separation between the equipment and the receiver.

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 

Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance may void the user’s authority to operate the equipment.

PRODUCT OVERVIEW

What’s in the Box

Parts Description

Qty

1.  DL-300 Data Logger
2.  Wi-Fi Antenna
3.  RS485 Cable
4.  Power Adapter
5.  RJ-45 Cable
6.  USB Flash Drive
7.  Din Rail
8.  Din Rail Mount
9.  Self-Tapping Screws
10.  M3 Screws
11.  Power Connector Adapter

1
1
1
1
1
1
1

2
2
4

1

Содержание DL-300

Страница 1: ...INSTALLATION MANUAL DL 300 DATA LOGGER...

Страница 2: ...Need Before You Begin 3 FCC Compliance 3 PRODUCT OVERVIEW 3 What s in the Box 3 Connections 4 LED Definitions 4 MOUNTING THE DATA LOGGER 4 Location Requirements 4 CONNECTING TO THE INVERTER 5 CONFIGUR...

Страница 3: ...ence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recept...

Страница 4: ...stem initialization There is no Power T0 RS485 Solid Solid Off A command is transmitted to the inverter s A command is received from the inverter s No commands are being transmitted or received T1 RS4...

Страница 5: ...s are in the correct position Grid and Bypass are on Load is off Step 3 Turn off the main switch that is located on the side of the inverter Step 4 Insert the black wire of the RS485 cable into the fi...

Страница 6: ...8 Internet Connection There are three ways to establish an internet connection LAN WiFi or Cellular LAN Connection Connect the ethernet cable to the data logger and to the network router WiFi Connect...

Страница 7: ...M I G 3 0 0 M I C R O I N V E R T E R I N S TA L L AT I O N M A N U A L Step 10 Turn the inverter on by the using Main Switch on the inverter Wait for the inverter to boot up before going to the next...

Страница 8: ...rowser and go to 192 168 100 1 If you are redirected to a warning page click on Advanced and then Proceed If not then go to the next step Note The wording and appearance of the warning page will vary...

Страница 9: ...6 branch git 19 020 41695 6f6641d SBC700 OpenWrt 18 06 2 r7676 cddd7b4c77 Load 0 00 0 00 0 00 Auto Refresh on Step 8 Click Switch protocol Powered by LuCI openwrt 18 06 branch git 19 020 41695 6f6641d...

Страница 10: ...cted back the network interfaces page Powered by LuCI openwrt 18 06 branch git 19 020 41695 6f6641d Step 14 In the sidebar menu click on Wireless Powered by LuCI openwrt 18 06 branch git 19 020 41695...

Страница 11: ...0 Auto Refresh on Powered by LuCI openwrt 18 06 branch git 19 020 41695 6f6641d Step 18 Click Save Apply and wait until you are redirected back the Wireless Overview page SBC700 OpenWrt 18 06 2 r7676...

Страница 12: ...system If you are an existing installer please follow the following steps to create an account for your customer If you are a new installer please contact a Darfon representative to create your insta...

Страница 13: ...owing format xx xx xx xx xx xx with colons between every two characters For example if the LAN MAC is 40D63C031E86 it should be entered as 40 D6 3C 03 1E 86 The Data Logger Name can be any nickname yo...

Страница 14: ...ttp portal darfon com SMS Account Add directly Or in the website menu select Account Mgmt Accounts to go to the Account list page then click the Add button Step 9 Complete all required fields denoted...

Страница 15: ...Storage Log USB 2 0 Type A 8G Flash Drive Included POWER Power Supply Input 12Vdc 2Adc Power Consumption 9 to 36Vdc 5W Typical MECHANICAL DATA Dimensions WxHxL 99x28x147mm 3 9x1 1x5 8in Weight 0 17kg...

Страница 16: ...in the following format xx xx xx xx xx xx with colons between every two characters For example if the LAN MAC is 40D63C031E86 it should be entered as 40 D6 3C 03 1E 86 Step 3 If the data logger is co...

Страница 17: ...3B Pioneer Way Taoyuan 333 Taiwan R O C Mountain View CA 94041 Tel 886 3 2508800 Tel 1 650 316 6300 2020 Darfon Electronics Corp All rights reserved All specifications are subject to change without pr...

Отзывы: