1.2 Cautions

 

 

 

The monitor is not a fully sealed device. Keep its surface dry and clean, and prevent 
any liquid from infiltrating it. 

 

The device should be positioned appropriately. Keep it from falling, strong vibration or 
other mechanical damage. 

 

Do not use mobile phones near where the monitor is operating. Mobile phones may 
emit electromagnetic radiation which is capable of interfering with the proper 
performance of the monitor. 

 

The monitor should only be maintained by personnel approved by our company. 

 

Before using the monitor on patients, the user should be familiar with its operation. 

 
IMPORTANT 
Before use, carefully read this manual, all safety information and specifications. 
 

The monitor is a non-invasive, handheld patient monitor. It operates on AC or rechargeable 
battery power supply. It is suitable for monitoring adult and child patients. It is widely used 
in the hospital’s operation room, ICU, clinic section office, out-patient department, 
sickroom, emergency treatment, and the recovery and health care organisations, or in 
family nursing and in patient transportation. 
 

Parameters measured by the monitor include: arterial oxygen saturation (SPO2), pulse rate 
(PR), plethysmogram waveform (PLETH), pulse strength and temperature (TEMP). The 
monitor measures these parameters through a SPO2 sensor and a TEMP sensor and displays 
them on the LCD screen.  
 

The monitor is operated and controlled by the buttons on the front panel. It adopts a 
monochrome LCD screen in displaying measurements and waveforms, and a dual-colour LED 
in supplementary status indication. It is also capable of managing measured data and 
transmitting the patient’s trend through the communication socket to a PC for display, 
observation, saving and printing.  

 

Function structure.

  

The monitor is composed of main unit, SPO2 sensor, TEMP probe and AC power adaptor. 

 

2. FUNCTIONS

 

 

 

The monitor has the following functions: 

 

Measuring: Intelligent display of SPO2, PR, PLETH, pulse strength and TEMP. 

 

Prompting: battery capacity, speaker volume. 

 

Alarm: judgement of exceeding the limits, Audio and visual alarm. 

 

Power saving: automatic shutdown when no monitoring. 

 

Data Managing: data storage, data adding, data deletion, drawing trend waveforms with 
saved data. 

 

Communication: transmitting the patient’s trend data to a PC for display, observation, 

saving and printing. 

 
For the data display, observation, saving and printing function, you must install the data 
viewer software in a PC equipped with a printer, and connect the monitor with the PC by a 
special communication cable.  

Содержание V402+

Страница 1: ...V402 HANDHELD PULSE OXIMETER TEMP MONITOR OPERATING MANUAL QAM V402 1 02 07...

Страница 2: ......

Страница 3: ...NS 6 3 INSTALLATION 8 4 DISPLAY AND OPERATION 9 5 SPO2 MONITORING 18 6 TEMP MONITORING 22 7 MAINTENANCE 23 8 V402 PATIENT MONITOR DATA VIEWER 26 9 PACKING LIST AND ACCESSORIES 26 RETURNS POLICY 29 WAR...

Страница 4: ...f the relevant room complies with the applicable national and local requirements This product is operated under strict observance of this manual The safety statements presented in this chapter refer t...

Страница 5: ...xplosive substances vapours or liquids Do not pull or lift the monitor by its cables It could lead to falling and consequent patient injury It is not recommended to hang the monitor when transporting...

Страница 6: ...ulse rate PR plethysmogram waveform PLETH pulse strength and temperature TEMP The monitor measures these parameters through a SPO2 sensor and a TEMP sensor and displays them on the LCD screen The moni...

Страница 7: ...eft in setup or viewing trend graphs 8 AC power adapter socket 9 PC serial link connector socket 10 Up arrow backlight Turns backlight on off whilst monitoring or moves cursor up in setup or viewing t...

Страница 8: ...adaptor s power indicator LED lights up Insert the adaptor s connector to the adaptor socket on the monitor s right side as shown in Fig 1 8 WARNING The AC power adaptor supplied is built to special...

Страница 9: ...removed from the sensor the monitor automatically enters standby mode In this mode when the SPO2 sensor is reconnected and a finger is inserted into the sensor or the TEMP cable is reconnected the mon...

Страница 10: ...only the SPO2 sensor is connected to monitor a patient s SPO2 the LCD screen displays the measurements of SPO2 PR and pulse strength status information and system information see Fig 3 Fig 3 TEMP Scre...

Страница 11: ...en displays PLETH waveform and measurements of the parameters See Fig 6 Fig 6 No Title Description 1 SPO2 SPO2 value refresh 1 second 2 Alarm audio ON OFF 3 Pulse strength Max 10 segments 4 Pulse audi...

Страница 12: ...screen If the speaker sound is turned off by pressing the Mute button or the parameter alarm switch is set off the parameter alarm sound will be silenced but the parameter s measurement still flashes...

Страница 13: ...cription of Information Displayed The meanings of the words and the ranges of the values in Fig 7 are listed in table 4 2 as follows Upper limit Lower limit Alarm SPO2 85 100 85 100 ON or OFF PR 40 25...

Страница 14: ...the maximum and start decreasing again With the cursor on the alarm on off positions press the up button to toggle between ON and OFF When the Down arrow button is pressed with the cursor on the DATA...

Страница 15: ...ue to the menu button is pressed on the other screen the monitor draws the parameter trend waveforms on the time measurement coordinate series One screen can only display 3 hours data which is defined...

Страница 16: ...ator The data forming one screen trend waveforms time period of 3 hours is defined as a page which corresponding to 90 units of the storage area The page indicator points out the position of this data...

Страница 17: ...or left and right in single steps but remains within the current page of data Up and Down Arrow Buttons The up and down arrow buttons move the time indicator 8 steps at a time When the time indicator...

Страница 18: ...d through the patient s tissue such as a finger or a toe to a receiver on the other side The sensor measurement wavelengths are nominally 660nm for the Red LED and 940nm for Infrared LED Maximum optic...

Страница 19: ...t 2 Turn on the monitor The LCD screen will display the parameter monitoring screen 3 Attach the sensor to an appropriate site on the patient s finger 4 The readings will be displayed on the LCD scree...

Страница 20: ...a xenon light source bilirubin lamps fluorescent lights infrared heating lamps or direct sunlight exposure to intense illumination can be corrected by covering the sensor with a dark material Excessiv...

Страница 21: ...orrect results Prolonged and continuous monitoring may increase jeopardy of unexpected change of dermal condition such as abnormal sensitivity rubescence vesicle repressive putrescence and so on It is...

Страница 22: ...Because the temperature sensor s impedance varies slowly with the temperature of the body an accurate result of temperature measurement is usually obtained after monitoring for more than 5 minutes 6 3...

Страница 23: ...ing the functional safety check after the monitor has been used for 6 12 consecutive months or after monitor servicing or system upgrading This is to ensure the normal operation of the system Store th...

Страница 24: ...h ppm depends on how much organic matter blood propagation grume etc existing on the surface CAUTION Never use strong solvent such as acetone ALWAYS dilute the solutions according to the manufacturer...

Страница 25: ...r or any solution or pour water or any solution on the equipment ALWAYS wipe off all the excess liquids on the equipment surface and accessory surface with a dry cloth Never use EtO and formaldehyde t...

Страница 26: ...ownload it from Internet and installed it in your PC Please refer to the download instruction and the HELP in SPDV for details NOTE The download and installation procedure maybe different depending on...

Страница 27: ...ounds the alarm and the parameter s measurement flashes on the screen Prompting Icons of battery capacity pulse sound switch and alarm sound switch Power saving The monitor will automatic shut down wh...

Страница 28: ...densing Altitude Operation 86 106 KPa Transportation and storage 50 106 KPa Parameter specifications SPO2 Patient Adult child Range 35 100 Resolution 1 Accuracy 70 99 2 0 69 Unspecified PR Range 30 25...

Страница 29: ...lp but we cannot normally offer a refund DOA dead on arrival For additional clarification please refer to our terms and conditions at www daray co uk terms In a small number of cases we may determine...

Страница 30: ...ray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray Damage caused by chemical corrosion from cl...

Страница 31: ...PURCHASED FROM PRODUCT SERIAL No ALTERNATIVELY REGISTER ONLINE AT WWW DARAY COM Freepost Plus RRAS YGXE SLBC Daray Ltd Marquis Drive SWADLINCOTE DE12 6EJ 1 YEAR WARRANTY Occasionally DARAY would like...

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...TM VetZ Antimicrobial protection BioProtect Marquis Drive Moira Derbyshire DE12 6EJ Tel 0870 777 2664 Fax 0870 777 2665 email info daray co uk url www daray co uk...

Отзывы: