Page 17 of 43
4.3.3 Installing the Ceiling plate
The location of the light should be decided by the end user / project manager or through
schematical drawings.
Once the location has been decided it will be necessary to first mark the location of the
fixing/ceiling plate.
As shown, fitting your ceiling plate requires bolts be inserted directly into the ceiling super
structure. The ceiling plate can however be fitted to an optional fixing plate instead. The fixing
plate would then attach to the ceiling super structure instead of the ceiling plate.
Whichever fixing method used; it is highly advisable that the plate being fixed to the ceiling, is
secured with a minimum of 4 bolting points to ensure a complete and sturdy fit.
Once the fixing plate is fitted and secured, you will need to attach a locking nut to each bolt
protruding from the fixing plate before attaching the ceiling plate. Now fit the ceiling plate to
the fixing plate by sliding the fixing points onto the bolts from the fixing plate and attach a 2
nd
nut to the bolts.
Fixing plate
Dimensions
Ceiling Superstructure
Locking Nut
Adjusting Nut
Fixing Plate
Ceiling
Plate
Ceiling Plate
Downtube
Fixing Bolt