Connection with the mains 

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 

 
 

International 

EU (including UK) 

From April 2004 

North America 

Pin 

Brown 

Black 

Phase  

Blue 

White 

Neutral 

 

Green/Yellow 

Green 

Protective Earth 

 
 
Make sure that the device is always connected 

properly

 to earth!  

 
 

      

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

device. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack the device, any shipping damage resulting from inadequate 
packaging is the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or 
replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to 
use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

 

 

Содержание GIG-12

Страница 1: ...GIG 12 ORDERCODE D2262 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands...

Страница 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Страница 3: ...tructions 3 Operating Determinations 4 Return Procedure 5 Claims 5 Description of the device 6 Features 6 Overview 6 Front panel 7 Back panel 9 Installation 9 Functions 10 Connection Cables 18 Mainten...

Страница 4: ...he system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please conside...

Страница 5: ...y to reduce the input signal level by using the INPUT control To emphasize a frequency range you don t necessarily have to move its respective control upward try lowering surrounding frequency ranges...

Страница 6: ...method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of th...

Страница 7: ...ternal input source It has inserts and low cut on the mono channels and selectable pre post aux send The stereo output is equipped with a contour function that will give your main mix extra body and a...

Страница 8: ...ol range mic 0 40dB line 25 15dB 7 Low cut filter button mono channel 1 4 8 EQ hi control range 15 15 dB 9 EQ mid control range 15 15 dB 10 EQ low control range 15 15 dB 11 Aux 1 level control 12 Aux...

Страница 9: ...33 Aux 2 return level control 34 Aux 2 to PFL button 35 Aux send level control 36 Tape in USB level control 37 Aux 1 to ST sub level control 38 Aux 1 to ST sub button 39 Aux 2 to ST sub level control...

Страница 10: ...send output 62 Stereo tape in inputs 63 Stereo record outputs 64 Stereo phones output Back panel Fig 5 65 Power on off switch 66 IEC inlet 67 USB port Installation Remove all packing materials from th...

Страница 11: ...can occur 4 Insert Insert for external device effect compressor etc The insert jack provides an output of the channels signal at line level At the same time the insert has an input at line level from...

Страница 12: ...ou to adjust the channel s level to the Aux bus 12 Channel pre post The pre post button toggles the aux 1 signal to be taken pre or post fader 13 Channel effects The Effects control allows you to adju...

Страница 13: ...room or phones output independent of the position of the channel fader 20 20 Channel fader The fader controls the volume of a single channel The channel faders should be positioned within the range o...

Страница 14: ...ght up So both balanced and unbalanced microphones can be connected Unbalanced microphones may be damaged if the phantom power is activated However unbalanced microphones are rarely to be found these...

Страница 15: ...aux 1 return 54 inputs to either the main ST bus or the sub bus depending on the position of the ST sub 38 button 38 Aux 1 ST sub Button Allows you to route the signal from the aux 1 return input con...

Страница 16: ...that the mains plug is plugged in correctly If the LED still doesn t light up please contact your DAP Audio dealer 48 LED VU meter 49 Tape USB button This button allows you to assign the VU meter to t...

Страница 17: ...you have to adjust the return level with the aux 2 ST sub 39 control 56 Stereo sub outputs Unbalanced 6 3mm jacks 57 Stereo control room outputs Unbalanced 6 3mm jacks 58 Stereo main outputs Unbalanc...

Страница 18: ...Do not supply power before the whole system is set up and connected properly 66 IEC power inlet This connector is meant for the connection of the supplied main cord Connect one end of the power cord...

Страница 19: ...s and twists when coiling them This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are...

Страница 20: ...nnections are thoroughly dry before linking equipment or supplying electric power Troubleshooting DAP Audio GIG 12 This troubleshooting guide is meant to help solve simple problems If a problem occurs...

Страница 21: ...x stereo return 10K CD Tape stereo input 10K Gain control Mono channels 50 dB Stereo channels 40 dB Aux FX 10 dB T H D 0 005 Any output 1Khz 14dBu 20Hz to 20Khz channel inputs S N 90 dB Frequency Resp...

Страница 22: ...20 Appendix 1 GIG 12 Block Diagram...

Страница 23: ......

Отзывы: