IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the system. 

 

 

Always let the device cool down before cleaning or servicing. 

 

Always disconnect power from the mains, when system is not used. Only handle the power cord by 

the plug. Never pull out the plug by tugging the power cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 

same electrical circuit to ensure the same phase! 

 

Before changing the ground, always turn off your amplifier. 

 

Connecting amplifier outputs to oscilloscopes or other test equipment, while the amplifier is in bridge 

mode, may damage both the amplifier and test equipment. 

 

Do not connect this device to a dimmer pack. 

 

Do not drive the inputs with a signal level bigger than required to drive the equipment to full output. 

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Do not put your equipment next to TV, radio, etc., because of interference or distortion. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 

engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your system. Leave the 

system switched off until it has reached room temperature. 

 

If you connect other parts of the system, beware ground loops. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 

(preferably in the original packing material) and return it to your Dap Audio dealer for service. 

 

In system setup, the amplifier's output power must be 50%-100% higher than the loaded loudspeakers 

rated power. 

 

In typical use, please set the volume to 0dB position. 

 

Make sure that the amplifier is turned down, before turning the power on or off. In this way you can 

avoid supersonic frequencies, which could damage your speakers. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 

cord from time to time. 

 

Make sure that the signals coming into the mixer are balanced, otherwise hum could be created. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Please turn off the power switch, when replacing the power cord, signal cable or selecting the input 

mode switch. 

 

Prevent distortion! Make sure that all components connected to the device have sufficient power 

ratings. Otherwise, distortion will be generated because the components are operated at their limits. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 

distributor. 

 

The best way to avoid ground loops is connecting the electrical system ground to one central point 

("star" system). In this case the mixer can act as a central point. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 

conductor to earth. 

 

The user is responsible for correct positioning and operating of the DM amplifier. The manufacturer 

will not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

  

 

 

   

 

Содержание DM-1000

Страница 1: ...DM 1000 DM 2000 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D4212 D4213 MANUAL ENGLISH...

Страница 2: ...tions 4 Return Procedure 4 Claims 4 Description of the device 5 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Stereo Connection 8 Parallel Connection 9 Bridge Connection 10 Connection C...

Страница 3: ...packing Your shipment includes DM 1000 DM 2000 Schuko power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be q...

Страница 4: ...cking material and return it to your Dap Audio dealer for service In system setup the amplifier s output power must be 50 100 higher than the loaded loudspeakers rated power In typical use please set...

Страница 5: ...repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece...

Страница 6: ...y PFC Switching Power Amp CLASS D Protections Short circuit open circuit thermal ultrasonic and RF protection Input connectors RCA and XLR Combo Output connectors 2x Speakon binding posts Dimensions 4...

Страница 7: ...s in protection mode Switch off the device and find out what the problem is The amplifier is protected against overheating overload short circuit etc Decrease the source signal level and or improve ai...

Страница 8: ...or hot Pin 1 3 Sleeve shield ground Mode switch Flick the switch to select your desired operation mode parallel bridge or stereo 3 pin XLR Link connector OUT Connect the DM to another amplifier RCA c...

Страница 9: ...ing or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging the unit in always make sure that the power supply matches the product specification...

Страница 10: ...Ordercode D4212 D4213 DM 1000 DM 2000 Parallel Connection Fig 04 9...

Страница 11: ...Ordercode D4212 D4213 DM 1000 DM 2000 Bridge Connection Fig 05 10...

Страница 12: ...onnection Maintenance The DM 1000 DM 2000 requires almost no maintenance However you should keep the unit clean Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immer...

Страница 13: ...lew rate 40 V S Input CMRR 60 dB Crosstalk 20 20 000 Hz 70 dB Signal to Noise Ratio 96 dB A weighted Power circuitry PFC Switching Power Amp CLASS D Protections Short circuit open circuit thermal ultr...

Страница 14: ...Ordercode D4212 D4213 DM 1000 DM 2000 Dimensions 13...

Страница 15: ...Ordercode D4212 D4213 DM 1000 DM 2000 14...

Страница 16: ...2016 DAP Audio...

Отзывы: