Do not open this device. Risk: hazardous radiation exposure. 

 

Only use system indoor, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when system is not used. Only handle the power-cord 
by the plug. Never pull out the plug by tugging the power-cord. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure that the signals into the device are balanced, otherwise hum could be created. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the system and the power-
cord from time to time. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground.  

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full 
output. 

 

In typical use, Please set the volume to 0dB position. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving 
your equipment. Should this occur, it is necessary to reduce the input signal level by using the 
INPUT control. 

 

For replacement use fuses of same type and rating only. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do 
not switch it on immediately. The arising condensation water might damage your system. Leave 
the system switched off until it has reached room temperature. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 
 

OPERATING DETERMINATIONS 

 

This system is not designed for permanent operation. Consistent operation breaks will ensure that the 
system will serve you for a long time without defects. 
 
If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 
 

Improper installation can cause serious damage to people and property !

 

 

 

Connection with the mains

 

 
Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU (including UK) 

From April 2004 

North America 

Pin 

Brown 

Black 

Phase  

Blue 

White 

Neutral 

 

Green/Yellow 

Green 

Protective Earth 

 

Make sure that the device is always connected 

properly

 to the earth! 

 
 
 

Содержание DCX-36 MKII

Страница 1: ...DCX 36 MKII ORDERCODE D2023...

Страница 2: ...AP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Страница 3: ...Operating Determinations Return Procedure Claims Description Features Overview Front side Overview Back side Installation Set Up and Operation X over submenu Safety Options System Menu Interface Menu...

Страница 4: ...perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused...

Страница 5: ...e to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is dropped or struck disconnect mains power supply immediately Have a qualified eng...

Страница 6: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Страница 7: ...protecting the program settings Phase Invert switch per output USB interface for remote control including PC software 2x XLR Input and 6x XLR Output Clip LED Software included for easy set up with DCX...

Страница 8: ...cted properly Main Menu Press the Menu 14 button to enter the main menu Select the desired submenu by pressing the Back 2 or Next 3 buttons and confirm your setting with the Enter 4 button Xover subme...

Страница 9: ...to the preset output volume Mute Hold all output remains muted 4 Delay Time Distance You can adjust the delay in milli seconds ms meters m feet ft Interface menu Interface Setup Baud Rate Here you can...

Страница 10: ...f the equalizer is activated you can adjust the frequency 20 Hz to 20 kHz the Q factor 0 5 to 10 and the gain 12 dB 1 dB By pressing the Parameter 17 knob you can jump to the next parameter Additional...

Страница 11: ...er_1025 EXE Next you have to install the DCX software by clicking on DCXSetup_V13 EXE Now connect the DCX 36 MKII via a USB cable to your computer Start up the DCX software by double Clicking the DCX...

Страница 12: ...e the Device ID matches the ID in your DCX 36 MKII factory set to 1 Now press OK and select RS232 in the Config menu Your screen will look as the figure below The DCX USB driver emulates a RS 232 port...

Страница 13: ...eal time editing you ll have to store the new settings to the DCX 36MKII first If you want to edit a program stored in the DCX 36 MKII you ll have to press the Refresh button in the Memory window firs...

Страница 14: ...12 Delay Settings Limiter Settings...

Страница 15: ...13 Out 1 Settings Filter Settings...

Страница 16: ...14 Out 2 Settings Out 3 Settings...

Страница 17: ...15 Out 4 Settings Out 5 Settings...

Страница 18: ...r settings select a memory location press store and your settings will be stored Click the erase button to erase a program you re not happy with Or click erase all to erase all programs in the DCX mem...

Страница 19: ...17...

Страница 20: ...18...

Страница 21: ...s and twists when coiling them This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are...

Страница 22: ...2 Insert a flat head screwdriver into a slot in the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder w...

Страница 23: ...aration 80 dB 30 Hz 20 KHz Crossover frequency 15 Hz 20 kHz Maximum output level Vpp 7 6V THD 0 005 Latency 180 s Delay Delay time 0 7 ms Parametric Equalizer Filter Gain 12 dB in 1 dB steps Central F...

Страница 24: ...22 Design and product specifications are subject to change without prior notice Website www Dap audio info Email service highlite nl...

Страница 25: ...2009 DapAudio...

Отзывы: